Sisitemu ya GDTL AC Resonant Sisitemu ya Generator
Sisitemu ya GDTL ya AC Resonant Sisitemu ya Generator irashobora gukoreshwa muguhindura inductance ya reaktor, cyangwa guhindura uburyo bwakazi bwumurongo wa sisitemu kugirango ugere kuri resonance.Ubwo buryo bwombi burashobora gukoreshwa kugirango ugere kuri resonance.Muburyo bwo kongera imbaraga za voltage, niba ingingo ya resonant itandukiriye, irashobora kuboneka neza muburyo bwo guhuza imirongo myiza, itanga agaciro keza Q kandi igabanya ubushobozi bwimbaraga nuburemere bwibikoresho byipimisha.
●Ingano ntoya, uburemere bworoshye ugereranije nurwego rumwe rwa voltage, generator yubushobozi bumwe AC ihanganira ibikoresho byo gupima voltage.Ibikoresho bimwe ntibirenza 60kg, byoroshye kugenda.
●Ihame ryambere ryibikoresho byose byashizweho hamwe na tekinoroji nshya & inductance modulation tekinoroji, menya neza ingufu za generator zihanganira ibisabwa na voltage.Ingano yo gusaba.
●Bifite ibikoresho 20Hz-300Hz bihinduka kugenzura isoko.Kurinda neza no gusohora ibyerekezo, guhagarara neza.Hamwe nuburyo bwinshi bwo gukora, byoroshye gukora.
●Amashanyarazi ya 220V cyangwa 380V, yorohereza amasoko kumashanyarazi。
●Ingingo ya Max.Q irashobora kuboneka neza nuburyo bwa modulisiyo ya mbere ya inductance hanyuma nyuma yo guhinduranya inshuro, kugirango wirinde gutandukana kwa resonance kubera kongera ingufu za voltage;
●Ibikoresho byoroshye no kwaguka gukomeye.Kuzuza ibisabwa byose byo gupima ibintu bisabwa muri sisitemu yimbaraga.
●Uburyo bwikizamini cyimbaraga cyangwa uburyo bwo kugerageza inshuro.
●Gukoresha byinshi, bikoresha ikiguzi.
●Ikigereranyo gisohoka voltage: 0 ~ 50kV (RMS) cyangwa munsi.
●Ibisohoka inshuro: 45 - 300Hz.
●Umuhengeri: umuyaga mwiza wa sine, THD ≤ 1%.
●Icyiza.ubushobozi: 2000kVA cyangwa munsi.
●Inshingano yinshingano: gukomeza gukora 15mins inshuro imwe kumashanyarazi yuzuye.
●Ikintu cyiza: 10 - 40.
●Guhindura inshuro inshuro: 0.1HZ, ihungabana rya <0.05%.
●Amashanyarazi: 220V cyangwa 380V ± 15%, 50HZ ± 5%.
GDTF- 100/50 | |
Injiza voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0- 50 |
Ubushobozi (kVA) | 100 |
Ingano yo gusaba | Generator - ubushobozi bwubutaka 0.07-0.13 μF |
10 kV (300 mm²) umugozi ≤ 1 km | |
Iboneza nyamukuru | 50kV / 1A reaction ihamye 1 seti |
50kV / 1A Igikoresho gishobora guhinduka 1 seti | |
Kugabanya ubushobozi bwa 50kV | |
GDTF-150/50 | |
Injiza voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0- 50 |
Ubushobozi (kVA) | 150 |
Ingano yo gusaba | Generator - ubushobozi bwubutaka 0.13-0.2 μF |
10 kV (300 mm²) umugozi ≤ 1.5 km | |
Iboneza nyamukuru | 50kV / 1.5A Imashini ihamye 1 set |
50kV / 1.5A Igikoresho gishobora guhinduka 1 set | |
Kugabanya ubushobozi bwa 50 kV | |
GDTF- 225/50 | |
Injiza voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0- 50 |
Ubushobozi (kVA) | 225 |
Ingano yo gusaba | Generator - ubushobozi bwubutaka 0.2-0.27 μF |
10 kV (300 mm ²) umugozi ≤ 2,5 km | |
Iboneza nyamukuru | 50kV / 1.5A Imashini ihamye ya seti 2 |
50kV / 1.5A Igikoresho gishobora guhinduka 1 set | |
Kugabanya ubushobozi bwa 50 kV | |
GDTF- 360/60 | |
Injiza voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0- 60 |
Ubushobozi (kVA) | 360 |
Ingano yo gusaba | Generator - ubushobozi bwubutaka 0.27-0.33 μF |
Iboneza nyamukuru | 60kV / 2A Imashini ihamye 1 seti |
60kV / 2A Igikoresho gishobora guhinduka 1 seti | |
Gutandukanya ubushobozi 60kV |