GD-610B Igenzura ry'amakosa

GD-610B Igenzura ry'amakosa

Ibisobanuro muri make:

Icyitegererezo GD-610B ikoreshwa mugutahura amakosa ya insulator no kumenya amakosa muri sitasiyo yumuriro, insimburangingo nta guca amashanyarazi.Irashobora kandi gukoreshwa mugushakisha PD, gutahura corona gusohora, gusohora ibikoresho byamashanyarazi.

 

 

 


Ibicuruzwa birambuye

Ibicuruzwa

GD-610B Igenzura ry'amakosa
Ibiranga

Ingano ntoya, uburemere bworoshye, udushya nuburyo bwiza, imikorere yuzuye, imikorere yoroshye kandi yihuse, umutekano kandi wizewe.
Kubintu bito cyangwa zeru insulator zirashobora guhita zitabaza.Irashobora gutahura insuliranteri yamenetse, ariko ntirasenyuka kubyangiritse bikomeye.
Kumenya intera ndende, laser igamije, guhagarara neza kwa insulator yangiritse hamwe nu mwanya wihariye wibikoresho byayo byananiranye, igipimo cyukuri ni 100%.
Ibintu bibiri byerekana stereo ya terefone na LCD yerekana, ingaruka ziragaragara.
Ubushobozi bukomeye bwo kurwanya kwivanga.
Urwego rwo hejuru rwubwenge:
Hamwe nimikorere yo gufunga amakuru.
Imikorere ya munsi ya voltage (Niba voltage nkeya, igikoresho kizahita gihita).
Kwishyuza buri gihe, imodoka ihagarara yonyine nyuma yuzuye.
Batiri ya Litiyumu-ion hamwe ninshuro 1000 yo kwishyuza, ifite sisitemu yo kwishyiriraho ubwenge kugirango yongere igihe cya bateri.

Ibisobanuro

Koresha intera: 6kV ~ 500kV

Umucumbitsi Inshuro ya Centre 40KHz ± 2Hz
Ibyiyumvo Uburyo bwo gusezerera: gusohora arc gusohora
Intera yo gusohora: 4mm
Umuvuduko:
AC 10kV intera 18M
AC 35kV intera 25M
AC 110kV intera 50M
AC 220-500kV intera 50M
Gukoresha voltage 7.4V (bateri ya lithium-ion * 2pcs)
Igipimo 250 * 125 * 140mm
Aluminiumibinyomoro
 
Laser Uburebure bwasohotse: 650nm
Gutandukana kw'ibiti: 0.4mard
Imbaraga zisohoka:50mw
Igipimo: 16 * 0mm
Rukuruzi rwinshi Umuyoboro wo hagati (fo): 40kHz±2Hz
Ubushobozi bwa Centre (Co): 2500±20% pF
Ubushyuhe bwo gukora: -20-60
Uburemere: 2.17 kg
Na terefone
 
Ikigereranyo cyateganijwe (Z) 125Ω
Ikirangantego 100Hz-10KHz
Ibyiyumvo (1W / 1m) 60dB
Amashanyarazi Injiza voltage AC 220V±10%
Kwinjiza inshuro 50Hz±5%
Ibisohoka DC voltage DC 8.4V
Ibiriho 5A
Ibipimo byo gupakira byose: 470 * 340 * 420mm
Ubushyuhe bwo gukora: -30-60;Ubushuhe: (0~100)% RH
Uburemere bwuzuye bwo gupakira: 7.18kg
Ibikoresho
Ikimenyetso cya GD-610B 1 set
Amashanyarazi Igice 1
Kugabanya cyane urusaku rwa terefone Igice 1
Amashanyarazi ya Laser Igice 1
Koresha Igice 1
Isanduku yububiko bwa plastike Kopi 1
Igitabo cyumukoresha Kopi 1
Icyemezo cya QC Kopi 1
Urutonde Kopi 1
Raporo y'ibizamini by'uruganda Kopi 1

  • Mbere:
  • Ibikurikira:

  • Ohereza ubutumwa bwawe kuri twe:

    Andika ubutumwa bwawe hano hanyuma utwohereze

    Ohereza ubutumwa bwawe kuri twe:

    Andika ubutumwa bwawe hano hanyuma utwohereze