Ikizamini cya GD2000D
GD2000D igerageza rya sisitemu yo kurwanya insuline ikorwa nisosiyete yacu ikoresha sisitemu yashyizwemo inganda imwe ya chip nyayo-sisitemu ikora.Imibare igereranya ya digitale hamwe na sisitemu yumurongo wa code yerekanwe hamwe.Uru ruhererekane rwa metero rufite urwego rutandukanye rwa voltage isohoka (250V, 500V, 1000V, 2500V, 5000V, 10000V), ubushobozi bunini, kurwanya-kwivanga, kwerekana analog hamwe no kwerekana ibyuma bya digitale, AC na DC ikoreshwa kabiri, imikorere yoroshye, kubara mu buryo bwikora ibipimo ngenderwaho bitandukanye (igipimo cyo kwinjiza, igipimo cya polarisiyasi), ibisubizo bitandukanye byo gupima hamwe nibikorwa birwanya imbaraga-hasi, nibindi. moteri ya voltage, ubushobozi bwamashanyarazi, insinga zamashanyarazi, nabafata inkuba.
DL / T 474-2006 "Ubuyobozi bwikizamini cyo gukumira ku rubuga"
DL / T 845-2004 "Ibisobanuro rusange byo gupima ibikoresho birwanya"
DL / T 846-2004 "Ibisobanuro rusange bya tekiniki kubikoresho bipima ingufu nyinshi"
DL / T 596-2005 "Kode yikizamini cyo gukumira ibikoresho byamashanyarazi"
GB50150-2006 "Igipimo cyo gutanga amaboko y'ibikoresho by'amashanyarazi ibikoresho byo gukoresha amashanyarazi"
GB / T16927.1 ~ 2-1997 "Tekinike yo gupima imbaraga nyinshi"
GB4793-1984 "Guhuza ibikorwa byo gukwirakwiza amashanyarazi no gukwirakwiza ibikoresho byinshi"
1. Umuvuduko w'amashanyarazi (250V / 500V / 1000V / 2500V / 5000V) .Urwego rwo guhangana 0-200GΩ.
2. Uburyo bubiri bwerekana kurwanya izirinda.
3. Igereranya-ryikigereranyo cyo kwinjiza hamwe na polarisiyasi.
4. Igikorwa cya gicuti, gukomeza kuzigama ibisubizo 19 byo gupima.
5. Auto-gusohora ibisigisigi byinshi bya voltage nyuma yikizamini kirangiye.
6. Amashanyarazi ya AC / DC, hamwe na bateri yumuriro cyangwa adaptate ya AC.
7. Ubushobozi bukomeye bwo kurwanya-kwivanga, gusoma bihamye kandi byizewe.
8. Igishushanyo mbonera, gikwiranye nakazi ko mwishyamba.
9. Umuyoboro mugari ≥3mA, ibikoresho byiza byo kugerageza kwihanganira insuline nini, inductor, generator, moteri ya HV, capacitori yamashanyarazi, insinga hamwe nabafata surge.
Ingingo No. | GD2000D | ||||||
Umuvuduko w'amashanyarazi | 250V DC | 500V DC | 1000V DC | 2500V DC | 5000V DC | ||
Ukuri | Ubushyuhe | 23 ℃ ± 5 ℃ | |||||
Kurwanya insulation | 250-5G ± 5% | 50-10G ± 5% | 1M-20G ± 5% | 2.5M-50G ± 5% | 5M-100G ± 5% | ||
Urundi rwego: ± 10% | |||||||
Umuvuduko w'amashanyarazi | 2M-10G ± 5% | 4M-20G ± 5% | 8M-40G 0 - + 10% | 20-100GΩ 0 - + 10% | 40-200G 0-- +10% | ||
SUmuyoboro wa hort | ≥3mA | ||||||
Amashanyarazi | 8*AA ubwoko bwimbaraga zishobora kwishyurwa bateri & adapt yo hanze | ||||||
Ubushyuhe bwo gukora. & Ubushuhe | -10 ℃ --40 ℃, max.ubushuhe bugereranijwe 85% | ||||||
Ububiko Ububiko. & Ubushuhe | -20 ℃ --60 ℃, max.ubushuhe bugereranijwe 90% | ||||||
Kwikingira | Max.2000MΩ iyo voltage hagati yumuzunguruko nigikonoshwa ni 1000VDC. | ||||||
Ihangane na voltage | Ihangane 1min mugihe voltage hagati yumuzunguruko nigikonoshwa ari3kV50Hz SineUmuvuduko wa AC | ||||||
Igipimo | 230mm * 190mm * 90mm (L * W * H) | ||||||
Ibiro | 3kg |
Ikizamini cyo kurwanya insulation | 1set |
Ikizamini | Igice |
Amashanyarazi | Igice |
Umugozi w'amashanyarazi | Igice |
Agatabo gafasha abakoresha | 1copy |
Icyemezo | 1copy |