GD3127 Urukurikirane rwumubyigano mwinshi wo kugerageza
Ikizamini cya GD3127 Ikizamini gikoreshwa cyane mukubungabunga ibikoresho byamashanyarazi muguhindura insimburangingo, uruganda rwamashanyarazi, nibindi. Birakwiriye gukora ibipimo byo kurwanya insulasiyo (IR), indangagaciro ya polarisiyasi (PI), igipimo cyo kwinjiza (DAR), ramp ( RAMP), kuyungurura (FR, 10s, 20s, 30s, 40s 4 guhitamo), voltage (V), ikigezweho (nA) yubwoko bwose bwibikoresho byumuvuduko mwinshi, harimo na switchgear, transformateur, reaction, capacator, moteri, generator ninsinga, n'ibindi
GD3127 Urukurikirane nigikoresho cyiza cyo kugerageza kumenyekanisha hakiri kare no kuvumbura gahunda yo gukumira cyangwa guhanura gahunda yo kunanirwa ibikoresho.Ni ngombwa cyane kwemeza ubuziranenge bwibicuruzwa n'umutekano wabantu nibikoresho bikora.Imikorere ya insulasiyo yibicuruzwa byamashanyarazi nikimwe mubimenyetso byingenzi byo gusuzuma ubwiza bwimikorere, bigaragazwa nikizamini cyo kurwanya insulation.
●Icyiza.bigufi> 5mA.
●Kurwanya insulasiyo (IR), indangagaciro ya polarisiyasi (PI), igipimo cyo kwinjiza (DAR).
●Ramp (RAMP), kuyungurura (FR), voltage (V).
●Mu buryo bwikora gukurikirana voltage nzima yikintu cyapimwe, hanyuma uhite ubuza ikizamini niba voltage irenze 36V, irinda neza igikoresho nuwabikoraga.
●Igikorwa cyigihe, byikora byandika igihe cyibizamini.
●Mu buryo bwikora gusohora voltage nini nyuma yo gupima birangiye, igihe cyo gusohora ntikirenza amasegonda 30.
●Imashanyarazi yikora.
●Kinini LCD ya ecran ya dot matrix yerekana hamwe nibikorwa bihamye.
●Igice cya kabiri cyibishishwa byubaka, birakomeye kandi biramba, urwego rwo kurinda IP65.
●Ubushobozi bunini bwa lithium yamashanyarazi.
●Imikorere yo kubika, irashobora guhita ibika ibice 1000 byigihe-cyibizamini byukuri hamwe nitariki yikizamini nigihe nigihe cyo kugerageza.
●Gukuramo imikorere, ifite ibikoresho bya USB, amakuru yamakuru arashobora koherezwa kuri mudasobwa kugirango isesengure ryibarurishamibare.
Imikorere | Kurwanya insulasiyo (IR), indangagaciro ya polarisiyasi (PI), igipimo cyo kwinjiza (DAR), ramp (RAMP), akayunguruzo (FR, 10s, 20s, 30s, 40s 4 guhitamo), voltage (V), ikigezweho (nA) |
Amashanyarazi | KwishyurwaBatiri5.2Ah |
Ikigereranyo cya voltage | GD3127: 250V, 500V, 1kV, 2.5kV, 5kV GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
Umuvuduko w'amashanyarazi accuracy | (5% -10%)±10V |
Ibipimo byo kurwanya insulation | GD3127:0.50MΩ~ 2.00TΩ GD3127B: 0.50MΩ~ 5.00TΩ |
Umuyoboro mugufi | > 5mA |
Icyerekezo cya polarisiyasi (PI) | Yego |
Ikigereranyo cyo gukuramo (DAR) | Yego |
Uburyo bwo kugerageza (RAMP) | Gerageza mu ntambwe ya 10% ya voltage yateganijwe kugeza voltage yagenwe |
Shungura uburyo bwo kugerageza | Amahitamo ane ya 10S, 20S, 30S, 40S |
Ikizamini cya voltage | Urwego: AC / DC 0V-1000V, ukuri:±5% rdg±3V |
Ikizamini cyubu | Urwego: 0.01nA-7mA, ukuri:±5% rdg±0.5nA |
Monitori ya voltage | Kurikirana voltage yikintu cyapimwe, ukurikirane uko isohoka nyuma yikizamini, kandi ubuze ikizamini mugihe voltage irenze 36V, urinde igikoresho nuwabikoraga |
Igihe cyizamini | Mu buryo bwikora wandike igihe cyikizamini, igihe cyagenwe: 0s~9999s |
Ububiko | Kubika mu buryo bwikora amakuru yikizamini hamwe nitariki nigihe, yose hamwe 1000 |
Itumanaho | Kuramo amakuru y'ibizamini yabitswe kuri mudasobwa ukoresheje umurongo w'itumanaho rya USB. |
Batteri | Hano hari urwego rwa bateri rwerekana, rwibutsa kwishyuza mugihe iyo voltage ya batiri iba mike |
Imashanyarazi yimodoka | Imashanyarazi izimya nyuma yiminota 15 |
Icyiciro cyo kurinda | IP65 / IP40 |
Kurwanya insulation | 50MΩ(1000V) (hagati yumuzingi wikizamini na shell) |
Ihangane na voltage | AC 3kV 50Hz 1min (hagati yumuzingi wikizamini nigikonoshwa) |
Ibipimo | IEC61010-1, IEC61326-1 |
Ubushyuhe bwo gukora nubushuhe | - 20℃ ~ +50 ℃ <80% RH |
Ubushyuhe n'ububiko | - 25℃ ~ +65℃80% RH |
Amashanyarazi | 220V AC 50Hz |
Igipimo (mm) | 280(L) * 260 (W) * 160 (H) |
Ibiro | 4400g (shyiramo bateri) |
Ikizamini cyo kurwanya insulation | 1 set |
Umuyoboro mwinshi wo kugerageza (Umutuku) | 1 igice |
Ikizamini(Icyatsi) | 1 igice |
Ikizaminiwire(Umukara) | 1 igice |
Amashanyarazi | 1 piece |
Umukoresha 'Ubuyobozi | Kopi 1 |
Ikizaminirkohereza | Kopi 1 |