GD6900 Ikizamini Cyubushobozi
GD6900 ipima ubushobozi nigihombo cya dielectric (tgδ) yibikoresho byamashanyarazi menshi.Nibikoresho byahujwe, byubatswe muri dielectric igihombo cyikizamini, ikirangantego gihindagurika cyoguhindura amashanyarazi, kuzamura transformateur hamwe na capacitori ya SF6.
Inkomoko nini ya voltage itangwa na inverter yimbere yibikoresho, ikoreshwa mugupima ikizamini nyuma yo kongera imbaraga.Niba wongeyeho igikombe cyokwirinda hamwe nigikoresho cyo kugenzura ubushyuhe, igihombo cya dielectric cyamavuta yamavuta arashobora kugeragezwa.
●Kora LCD yerekana.
●Ibipimo byo kurwanya insulasiyo: Byubatswe muri moduline yikizamini cyo kurwanya insulasiyo, irashobora gukora irwanya insulasiyo (IR), igipimo cyo kwinjiza (DAR), igipimo cya polarisiyasi (PI).
●Kalendari chip hamwe nububiko bunini imbere.Bika ibisubizo byikizamini ukurikije igihe cyateganijwe, reba amateka yanditse hanyuma wandike ibisubizo.
●Ibikoresho byamakuru bishobora koherezwa muri U disiki.
●Uburyo bwinshi bwo kwipimisha, hamwe nuburyo bwimbere mumashanyarazi menshi, hanze yumuvuduko mwinshi, urwego rwimbere, urwego rwo hanze, GST / UST, kwishima.Umuvuduko mwinshi (urenze 10kV) dielectric igihombo gishobora gukorwa mugihe cyibisanzwe hanze hanze ya voltage ndende.
●Gerageza byuzuye CVT (Capacitive Voltage Transformer) C1 na C2 gutakaza dielectric hamwe na capacitance icyarimwe.Gerageza kandi igipimo cya CVT ihinduka na voltage inguni itandukanye.
●Igihombo cya dielectric hamwe nubushobozi bwa C0 kumpera yo hejuru ya CVT birashobora gupimwa ukoresheje uburyo bwo gukingira.
●Ikimenyetso cyihuta cyo gutoranya ibimenyetso.Inverter hamwe nicyitegererezo cyimbere imbere bigizwe numubare.Umuvuduko w'amashanyarazi usohoka uhoraho.
●LCR gupima byikora.Inductance, capacitance, resistance, inguni irashobora gupimwa no kwerekanwa.
●Kurinda inshuro nyinshi kwinjiza voltage ihindagurika, ibisohoka bigufi byumuzunguruko, hejuru ya voltage, hejuru-yubushyuhe, ubushyuhe, umutekano kandi wizewe.Hagati aho, ifite imikorere yo gupima hasi, ko kongera ingufu za voltage bitemewe kubikoresho bidafite ubutaka.
●Ntibikenewe gusenya HV biganisha ku gupima igihombo cya dielectric na capacitance ya CVT.
●Umuvuduko urashobora guhinduka muri 50Hz, 47.5Hz / 52.5Hz, 45Hz / 55Hz, 60Hz, 57.5Hz / 62.5Hz, 55Hz / 65Hz.
Imiterere y'akazi | -15 ℃ ~ 40 ℃ | RH <80% | ||||||
Ihame ryo kurwanya kwivanga | Guhindura inshuro | |||||||
Amashanyarazi | AC 220V ± 10%, 50 / 60Hz | Imashini irashobora gukoreshwa. | ||||||
Umuvuduko mwinshi mwinshi | AC 0.5KV ~ 10KV (12kV itabishaka) | Buri 0.1kV | ||||||
Ukuri | 2% | |||||||
Icyiza.ikigezweho | 200mA | |||||||
Ubushobozi | 2000VA | |||||||
Imbaraga zo kwishima | AC 0V ~ 50V / 15A | 50Hz, 60Hz inshuro imwe 45HZ / 55HZ 47.5HZ / 52.5HZ 55HZ / 65HZ 57.5HZ / 62.5HZ Automatic dual frequency | ||||||
Icyemezo | tgδ: 0.001% | Cx: 0.001pF | ||||||
Ukuri | ∆tgδ: ± (gusoma * 1.0% + 0.040%) | |||||||
∆C x: ± (gusoma * 1.0% + 1.00PF) | ||||||||
Urwego rwo gupima | tgδ | Nta mupaka | ||||||
C x | 15pF <Cx <300nF | |||||||
10KV | Cx <60 nF | |||||||
5KV | Cx <150 nF | |||||||
1KV | Cx <300 nF | |||||||
Ikizamini cya CVT | Cx <300 nF | |||||||
Ikigereranyo cya LCR | L> 20H (2kV) | R> 10KΩ (2kV) | ||||||
Ibipimo bya LCR | 0.1% | Icyemezo | 0.01 | |||||
Ikigereranyo cya CVT | 10 ~ 10000 | |||||||
Ikigereranyo cya CVT | 0.1% | |||||||
Ikigereranyo cya CVT | 0.01 | |||||||
Kurwanya insulation | DC Umuvuduko mwinshi | 5 ~ 10kV | Ukuri | ± (2% * Gusoma + 10V) | ||||
IR | 100kΩ-1000GΩ: <5% (voltage yikizamini kitari munsi ya 250V) 100GΩ-1000GΩ: 10% (voltage yikizamini kitari munsi ya 10000V) | |||||||
Igipimo | Igice nyamukuru: 350 (L) × 270 (W) × 270 (H) | |||||||
Agasanduku k'ibikoresho: 350 (L) × 270 (W) × 160 (H) | ||||||||
Ubushobozi bwo kwibuka | Amatsinda 200, ububiko bwa USB flash disiki burashyigikiwe. | |||||||
Ibiro | Igice nyamukuru: 22,75Kg | |||||||
Agasanduku k'ibikoresho: 5.25Kg |
Ikizamini | 1 set |
Urubanza | Igice 1 |
HV ikizamini gitukura kiyobora 8m | Igice 1 |
LV ikizamini cyirabura kiyobora 8m | Igice 1 |
Umugozi w'amashanyarazi 1.8m | Igice 1 |
CVT Guhuza kuyobora 5m | Igice 1 |
Isonga y'ubutaka 2m | Igice 1 |
Shira impapuro | Imizingo 2 |
10A fuse | Ibice 3 |
Agatabo gafasha abakoresha | Kopi 1 |
Raporo y'Ikizamini cy'Uruganda | Kopi 1 |
Ibikoresho bidahitamo | |
Ingirabuzimafatizo | 1 pc |
Igenzura | 1 pc |
Hamwe na selile yipima amavuta hamwe nubushyuhe, uyikoresha arashobora kugerageza tan delta yamazi ya dielectric nkamavuta ya transformateur.
Igenzura
Ubwato bwa peteroli