GD8000C SF6 Sisitemu yo Kugenzura Kumurongo
Sisitemu yo kugenzura kumurongo GD8000C ikoreshwa cyane mubyumba byo guhinduranya 35KV SF6 hamwe na 500KV, 220KV, 110KV GIS mucyumba cyo kugenzura imyuka ya gaze ya SF6 muri SF6 ihujwe n’ibikoresho by’amashanyarazi hamwe n’umwuka wa ogisijeni mu kirere mu gihe gikwiye. .
Iyo gaze ya SF6 isohotse, ubucucike bwa gaze ya SF6 bwikubye inshuro zirenga 5 ubw'umwuka, wegeranya mu mwanya muto kandi ugatera kubura ogisijeni yaho, bishobora guteza impanuka zikomeye.Sisitemu ikoresha ibice byinshi bishya-byunvikana byinjira hanze ya sensor ya SF6-O2 hamwe nubushyuhe nubushyuhe.Iyo intumbero yo mu nzu ya SF6 na O2 ihindutse gato, sensor zirashobora guhita zisubiza izo mpinduka, nubwo SF6 yibanda kuri 10ppmv irashobora gukurikiranwa neza.
Impinduka yibitekerezo ikurikiranwa na sensor ihindurwamo ibimenyetso byitumanaho 485 byitumanaho na transmitter, A / D module, 485 module itumanaho na microcomputer imwe, kandi ikimenyetso cyoherezwa kumugenzuzi mukuru binyuze kumurongo RS-485 bus.Umugenzuzi mukuru akora amakuru kandi akabika, akanareba niba gutabaza, gutangira umufana n’itumanaho rya kure nibindi bikorwa.
●Gukurikirana ibidukikije muri GIS
●Gukurikirana ibidukikije mucyumba cyo guhinduranya SF6
●SF6 ikora gaze nziza
●Intego & D intego
●10.1koraho gukoraho ibara rya ecran.
●Ihitamo rya sensor iroroshye guhinduka, hamwe na sensor ya infragre, ibyuma byamashanyarazi, hamwe na ultrasonic sensor.Ukurikije urubuga rutandukanye, birashobora guhuzwa no guhitamo kandi bigahinduka.
●Uruganda-rwibanze rwa ARM rwibanze, rushyigikira sisitemu nziza ya software, ituma ibicuruzwa byizewe.
●Ubwenge bwubwenge algorithm irashobora gukuraho sensor ibinyoma biterwa nimpamvu zitandukanye.
●Ubwenge bwa zeru drift kalibrasi yongerera ubuzima bwa sensor.
●Umubiri wumuntu ibikorwa byo gukurikirana byikora.Iyo umuntu ageze ku bwinjiriro bwibidukikije byakurikiranwe, igice nyamukuru gihita kimenya ibimenyetso byumubiri wumuntu.Igice nyamukuru kizahita gitangira kandi gitange raporo ikurikirana amakuru yibidukikije.
●Amakuru yo gutabaza hamwe na gahunda yo guhumeka birishyiraho, kandi uyikoresha arashobora gushyiraho amakuru yo gutabaza akurikije amabwiriza.
●Kurwanya anti-electromagnetic interineti yumuzunguruko, byizewe.
●Irashobora kwagura itumanaho rya USB, itumanaho ryuruhererekane, hamwe nuburyo bwo gutumanaho butagira umugozi, kandi irashobora kumenya ibikorwa byitumanaho no gucapa PC.(Bihitamo)
●Gukurikirana no kwerekana imikorere yibintu bya ogisijeni mubidukikije.
●SF6 gukurikirana ibirimo gaze no kwerekana imikorere mubidukikije.
●Ubushyuhe bwibidukikije nubushuhe bwo gukurikirana ibikorwa.
●Igikorwa cyo gutabaza Hypoxia.
●SF6 ibirimo birenze ibikorwa bisanzwe byo gutabaza.
●Imikorere isanzwe.
●Hypoxia cyangwa SF6 ibirimo birenze imikorere isanzwe, imbaraga zumuriro.
●Intoki ku gahato imikorere.
●Imikorere yanyuma yo kwerekana.
●Igihe nyacyo cyo kwerekana imikorere itandukanye.
●Ibikorwa byamateka yibibazo.
●Imikorere idasanzwe ya buri munsi ya zeru ya kalibrasi, ihita itsindira drift nibimenyesha ibinyoma.
●Umukoresha-ushobora kugenzura intera.Mu buryo bwikora gushimangira imikorere yo gukurikirana ingingo zikekwa.
●Iyo impuruza ibaye, umufana nijwi nijwi ryamatara bihita bifungura.
●Abakoresha barashobora guhindura ibipimo byo gutabaza bya SF6 na O2
●Shyigikira imikorere ya RTU ya kure.
●Ibikorwa byinshi byo gutabaza amakuru yububiko, igishushanyo mbonera cyubuzima
●Hamwe no kwiyongera kugiciro gito, ingingo zo gutahura zirashobora gukuba kabiri kugirango zongere ubwinshi bwikimenyetso.
●Igishushanyo mbonera cyimbaraga 185- 250VAC, anti-surge n'umurimo wumurabyo.
●Kwinjiza umubiri wumuntu, guhita utangiza sisitemu yabafana cyangwa amajwi
●Iyerekana irahagaze neza kandi ikemura ikibazo cya drift.
●Ihuze na PC kugirango ugere kure, kandi wandike ibyabaye nibyabaye mumateka.
●Ingano yabakiriye: 400 × 300 × 200
●Ikigereranyo cya SF6 cyo kumenya: 0-1500ppm
ibyiyumvo: ± 5% gushiraho agaciro
●Kumenya urugero rwa ogisijeni: 0-25%
●Ibipimo bya Oxygene neza: <0.5% (0.4%, O2 kuri 21%)
●Impanuka ya Hypoxia: 18.0% (irashobora guhinduka)
●Ubushyuhe bwo kwerekana urwego: -20--99 ℃
●Ubushuhe bwerekana urugero: 0--99% RH
●Ingingo yo kumenya: Ukurikije uko ibintu bimeze kurubuga
●Igikorwa cyo gufata amakuru: gufata mu buryo bwikora ibyabaye byo gutabaza, kubika imbaga, no kuvugurura byikora.
●Imenyekanisha risohoka: Shyira ahagaragara ibisohoka bidafite ishingiro, birashobora guhuzwa na RTU, kandi bigashyigikira ibyasohotse RS485.
●Shyigikira ibikorwa bya kure bya RTU.
●Shyigikira infragre yumubiri wumuntu, uhite utangira umufana cyangwa ijwi ryihuta.
●Umugenzuzi w'abafana:
Hindura ubwoko: kugenzura neza amashanyarazi yatanzwe.
Ubwoko bwa pulse: Ihujwe na switch igenzura abafana;irashobora gutoranywa ukurikije uko ibintu bimeze.
●Umufana utangira ashyigikira uburyo bwinshi: gutangira igihe, gutabaza, gutangira byikora iyo hari umuntu, gutangira kure, gutangira intoki, nibindi.
●Uburyo bwo guhitamo kubice byingenzi: urukuta rwubatswe hejuru-iturika / 3U / 19-isanzwe isanzwe cyangwa 10-ikora kuri interineti ya Android.(ku ihitamo.)
●Shyigikira kure yohereza amakuru yo gupima ukoresheje RS485.Kurugero, shyiramo LED nini yerekana kumuryango, hanyuma uhite ubona ibipimo byo gupima hamwe na sisitemu ikora kure (ihitamo kubakoresha)