GDB-H Intoki Yikora Automatic Transformer Ihindura Ikigereranyo
GDB-H ni igikoresho gifashwe n'intoki.Irashobora gupima neza impinduka zingana, itsinda hamwe nicyiciro cya fonction, ikwiranye nubwoko bwose bwimpinduka nka Z ubwoko bwa Z, guhinduranya ibyuma, guhinduranya itanura ryamashanyarazi, guhinduranya ibyiciro, guhinduranya ibice, guhinduranya ibintu, guhinduranya no guhinduranya ibintu.
●5.6inch TFT ibara LCD ecran, yerekana neza amakuru nishusho ya vector.
●Kwipimisha ibyiciro 3 icyarimwe.Icyiciro kimwe cyingufu zinjiza, hamwe na digitale y'imbere ihuza sine wave test isoko.Itanga ibyiciro 3 byo kugerageza imbaraga (urwego rwo kugoreka ruri munsi ya 0.1%, urwego rwo guhuza ruruta 0,05%) na Hi-fi power amplifier.Ibisubizo by'ibizamini bifite uburinganire bwiza, kandi ntibizagaragara ko intore zidaciriye urubanza.
●Byombi gupima icyiciro kimwe hamwe nicyiciro cya 3 cyikora.Irashobora gupima polarite na fonction angle munsi yicyiciro kimwe cyangwa icyiciro cya 3.Igihe kimwe wuzuze igipimo cyo guhinduka, icyiciro cy'inguni, ikosa, umwanya wo gukanda, kanda agaciro ka AB, BC, CA.Umubare w'itsinda urashobora guhita umenyekana.
●Imikorere yo gupima icyiciro.Gupima neza icyiciro cya fonction hagati ya voltage nini na voltage nto.Irashobora kandi gupima impinduka zingana nu mpande za “Non-integral point” impinduka.
●Ibisubizo byikizamini byerekanwa nigishushanyo na mpande esheshatu, byerekana mu buryo butaziguye itsinda rihuza itsinda.
●Ntabwo ari ngombwa guhitamo inzira ihuza cyangwa itsinda ryihuza, irashobora gupima Y / △, △ / Y transformateur idafite aho ihuriye.Irashobora kandi guhindura inzira ihuza ukurikije ibintu byatoranijwe.Transformer idafite icyapa irashobora gupimwa.
●Gupima byihuse impinduka zingana nikigereranyo cya buri kanda ihinduranya.Gusa ibyinjijwe byagereranijwe inshuro imwe, ntagikenewe kwinjizwa kugirango ubare ikosa ryikigereranyo cya buri kanda.
●Hamwe nimikorere yimpinduka zombi igipimo cyo gupima no gupima ibipimo bya voltage.Ikigereranyo cyibikorwa gishobora kwerekana rwose agaciro nyako ka voltage mugihe cyo gukora.
●Hamwe no guhangana neza.
●Inkomoko yikizamini cyiki gikoresho ni sisitemu ya synthesis isanzwe sine wave isoko.Impamyabumenyi yo kugoreka iri munsi ya 0.1%, ntabwo iterwa nubwiza bwo gutanga amashanyarazi.
●Ingano nto, uburemere bworoshye, byoroshye gutwara.
●Yubatswe-ifite ingufu nyinshi zishobora kwishyurwa bateri ya Litiyumu-ion.Ikizamini kirashobora kurangira nta mbaraga.Igihe kimwe cyuzuye cyuzuye gifata inshuro zirenga 800 zikomeza gupimwa.
●Ikibanza cyo guhinduranya amakuru gishobora kubikwa, kandi ibisubizo birashobora kwimurwa muri PC na U disiki.
●Urwego rwo gupima TTR: 0.8 ~ 10000.
●Umuvuduko wo gupima byihuse: ikizamini cyibyiciro bitatu kirashobora kurangira mumasegonda 60.
●Ibipimo bifatika:
Ibipimo bya voltage neza kuruhande rwa HV: 0.05%
Ibipimo bya voltage neza kuruhande rwa LV: 0.1%
Icyiciro cyo gupima icyiciro neza: 0.1 °
Ibipimo byo gupima TTR: 0.1% (0.8-3000)
0.2% (3000-10000)
●Uburemere: hafi 3Kg.
Igikoresho cya GDB-H | 1pc |
Urubanza | 1pc |
HV Ikizamini Cyambere hamwe na clamp | 1set |
LV Ikizamini Cyambere hamwe na clamp | 1set |
Fuse | 2pc |
Amashanyarazi | 1pc |
Imfashanyigisho y'abakoresha | 1pc |
Raporo y'ibizamini by'uruganda | 1pc |