GDCR-3200C Ikubye kabiri Clamp Igikorwa Cyinshi cyo Kurwanya Isi
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester yateguwe kandi ikorerwa mugupima ahabigenewe gupima ubutaka, kurwanya ubutaka, imbaraga z'ubutaka, kumeneka kumurongo, amashanyarazi ya AC hamwe na DC.Igikoresho gikoresha ikoranabuhanga rigezweho rya tekinoroji, hamwe nuburyo bwa 2, uburyo bwa 3, uburyo bwa 4, uburyo bwo guhitamo, uburyo bwa clamp nuburyo bubiri bwo gupima;Kuzana tekinoroji ya FFT (Byihuta Byihuta), tekinoroji ya AFC (Automatic Frequency Control), hamwe nubushobozi budasanzwe bwo kurwanya kwivanga no guhuza ibidukikije, guhuza ibizamini inshuro nyinshi, kwemeza neza, guhagarara neza no kwizerwa cyane mugupima igihe kirekire. Igikoresho cyakoreshejwe nini ya kalibiri ya clamp igishushanyo, irashobora guhangana nubwoko bwose bwibizamini bisabwa, irashobora gupima agaciro kangana nubunini bwubutaka bunini hasi hasi, byoroshye gupima agaciro kangana nubutaka bwikintu kimwe hamwe nubutaka bwubwoko bwose, nta mpamvu yo guhagarika ikintu icyo ari cyo cyose kibangikanye nisi pole mugihe cyo gupima sisitemu igereranya, itezimbere cyane uburyo bwo gupima, kuberako ikizamini cyo gukora gitanga igisubizo cyiza.
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester igizwe nimashini yakira, clamp iriho ubu (clamp ebyiri), insinga zipimisha, inkoni yubutaka ifasha, software yamakuru hamwe ninsinga zitumanaho nibindi.LCD nini yerekana imashini yakira ifite itara ryera hamwe nigishushanyo mbonera gishobora kugaragara neza.Ikizamini gifite imikorere yo kubika, imikorere yisaha, kandi ihita ibika amatsinda 2000 y ibisubizo byikizamini birimo itariki nigihe. Ikizamini hamwe nigikorwa cyitumanaho rya Bluetooth gishyigikira sisitemu ya Android.Nyuma yo kwishyiriraho APP, irashobora kugerageza cyangwa gusoma inyandiko yikizamini muri terefone igendanwa, izana uburambe bushya.Ikizamini gifite ibikoresho bya USB, kandi amakuru yabitswe arashobora koherezwa kuri PC binyuze muri USB.Porogaramu y'itumanaho irashobora kumenya imirimo yo gusoma, kugisha inama, kuzigama, gutanga raporo no gucapa amakuru yamateka.Ikoreshwa cyane mumashanyarazi, itumanaho, meteorologiya, imirima ya peteroli, ubwubatsi, kurinda inkuba nibikoresho byamashanyarazi.
●Igishushanyo cyihariye cyerekana urumuri rwa jack, kwerekana neza imyanya ya jack, irinde ikosa ryimikorere.
●Ibikoresho byo gutoranya ibikoresho, uburyo butandukanye bwo kugerageza burerekanwa, bigatuma imikorere yoroshye kandi yihuse.
●Ikizamini gifite imikorere yitumanaho rya Bluetooth kandi gishyigikira sisitemu ya Android.Abakoresha barashobora gukoresha terefone igendanwa kugirango bagerageze imikorere cyangwa basome ibisubizo byikizamini birimo itariki nigihe byoroshye.
●Igikoresho cyibikoresho bifata agasanduku karinda amazi, gakomeye, umutekano kandi karamba mu kurwanya kugongana, kurwanya kugwa no kwirinda amazi (icyiciro cyo kurinda IP65), cyane cyane gikoreshwa mu nyubako zubatswe hanze.
●Imetero ifite ibikoresho binini bya lithium yamashanyarazi.Kandi hamwe na USB interineti kugirango wohereze imikorere yamakuru.
Ibanze shingiro & Imiterere yakazi
Umubare w'ingaruka | Imiterere shingiro | Imiterere y'akazi | Ongera wibuke |
Ibidukikije | 23 ℃ ± 1 ℃ | -10 ℃ -40 ℃ | ---- |
Ubushuhe bw’ibidukikije | 40% -60% | <80% | ---- |
Umuvuduko w'akazi | 7.8V ± 0.1V | DC 7.8V ± 0.6V | ---- |
Umufasha w'isi Kurwanya | <100Ω | <5kΩ | |
Umuvuduko wimbaraga | Ugomba kwirinda | <20V | |
Kwivanga kurubu | Ugomba kwirinda | <2A | |
Intera ya Electrode mugihe upima R. | a>5d | a>5d | |
Intera ya Electrode mugihe upima ρ | a>20h | a>20h |
Ibisobanuro rusange
Imikorere | Gupima kurwanya ubutaka, kurwanya ubutaka;Kurwanya DC, imbaraga z'isi, guhinduranya amashanyarazi, kumeneka | |
Amashanyarazi | DC 7.4V 2600mAh bateri ya lithium yumuriro, yuzuye hafi 8.4V | |
Amatara | Igenzura rya ecran yinyuma, ibereye ahantu hacuramye | |
Uburyo bwo gupima | Kurwanya DC | DC kurwanya 2-wire uburyo |
DC irwanya uburyo bwa 4-wire | ||
Kurwanya isi | Isi irwanya isi 2-wire uburyo | |
Kurwanya isi uburyo 3-wire | ||
Kurwanya isi uburyo bwa 4-wire | ||
Isi irwanya isi clamp imwe uburyo bwa 3-wire (uburyo bwo guhitamo) | ||
Isi irwanya isi imwe clamp 4-wire uburyo (uburyo bwo guhitamo) | ||
Kurwanya isi doububuryo bwa clamp | ||
Kurwanya ubutaka (Uburyo bwa Wenner) | ||
Isi | Ibipimo bya clamp | |
Umuvuduko w'isi | Ikigereranyo cyo gukosora | |
Ikizamini cya Voltage Umuhengeri | Umuhengeri | |
Inshuro yikizamini | 128Hz / 111Hz / 105Hz / 94Hz (AFC) | |
Ikizamini kigufi-kizunguruka Ikizamini | AC 250mA max | |
Gufungura-kuzenguruka Ikizamini kigezweho | AC 40V max | |
Ikirere cya Electrode | 1m-100m | |
Uburyo bwo kwerekana | 4-digitale nini ya LCD yerekana, hamwe na ecran yinyuma | |
Igipimo cyo gupima | Mugihe cyo gupima, LED flash yerekana, LCD ibara ryerekana | |
Ikigereranyo cya LCD | 128mm × 75mm | |
LCD yerekana ahantu | 124mm × 67mm | |
Igipimo cy'igikoresho | 280mm (L) X 260mm (W) X 160mm (H) | |
Ingano ya CT | 223mm X 120mm X 39mm | |
Ikizamini | Insinga 4: buri kuri 20m itukura, umukara 20m, umuhondo 10m, nicyatsi 10m | |
Ikigereranyo Cyoroshye | Insinga 2: buri kuri umutuku 1,6m n'umukara 1.6m | |
Inkunga ifasha inkoni | 4PCS: Φ10mm X150mm | |
Clamp y'ubu | 2PCS: icyuma 1 cyubururu-umukara nicyuma 1 gitukura-umukara | |
Calibre Calibre | Φ 70mm | |
Clamp Lead Wire | 2m | |
Igipimo cyo gupima | Umuyoboro wa AC: inshuro 2 / isegonda | |
Umuvuduko w'isi: hafi inshuro 2 / isegonda | ||
Kurwanya isi: amasegonda 7 / isaha | ||
Gupima Ibihe | Inshuro zirenga 5000 (Ikizamini kigufi-cyizunguruka, igihe cyigihe kigomba kuba byibuze amasegonda 30) | |
Umuyoboro w'umurongo | Ibipimo biri munsi ya AC 600V | |
Imigaragarire y'itumanaho | Module ya Bluetooth, interineti ya USB, amakuru yo kubika arashobora koherezwa kuri mudasobwa, kubika cyangwa gucapwa. | |
Umugozi w'itumanaho | USB itumanaho USB x1pcs, ifite uburebure bwa 1.5m | |
Gufata Amakuru | Igikorwa cyo gufata amakuru: kwerekana ikimenyetso "HOLD" | |
Ububiko bwamakuru | Amatsinda 2000, icyerekezo cyo kubika "MEM", "FULL" ikimenyetso flash yerekana ububiko bwuzuye | |
Kubona amakuru | Imikorere yo gusoma amakuru: "SOMA" ikimenyetso cyerekana | |
Kwerekana Byuzuye | Kurenza gupima urwego rwuzuye imikorere: "OL" ikimenyetso cyerekana | |
Ibipimo Bigezweho Byerekana clamp | Gupima hamwe nuburyo bwo guhitamo cyangwa clamp ebyiri, ibimenyetso byubu byakiriwe na CT2 biri munsi ya 0.5mA, bizerekana "", kandi bigomba kugenzura icyerekezo cya clamp ya CT2 ya clamp | |
Ikizamini cyo Kwivanga | Kumenyekanisha mu buryo bwikora ibimenyetso byokubangamira, "URWISE" ikimenyetso cyerekana mugihe voltage yo guhagarara irenze 5V | |
Ikizamini cyo Gufasha | Hamwe nimikorere yikizamini cyo guhangana nubutaka, 0.00KΩ-30kΩ (100R + rC <50kΩ, 100R + rP <50kΩ) | |
Imikorere yo kumenyesha | Gupima agaciro karenze igiciro cyo gutabaza, bizakora "Toot-toot-toot" ijwi ryamagambo. | |
Umuvuduko wa Batiri | Mugihe ingufu za batiri zigabanuka kugera kuri 7.2V ± 0.1V, izerekana ingufu za batiri ikimenyetso gito, kandi yibutsa gusimbuza bateri | |
Guhagarika byikora | Mu buryo bwikora funga nyuma yiminota 15 yingufu | |
Ibikorwa Byubu | Itara ryinyuma: 25mA Max (gusa gukoresha urumuri rwinyuma) | |
Guhagarara: 25mA Max (Itara ryimbere nyuma yimbaraga kuri) | ||
Igipimo: 150mA Max (Itara ryinyuma rifunga) | ||
Ibiro | Ikizamini: 2290g | |
Clamp y'ubu: 1100g (2pcs) | ||
Uburemere bwose: 6800g (shyiramo ibikoresho byose) | ||
Ubushyuhe bwo gukora & Ubushuhe | -10 ℃ -40 ℃, munsi ya 80% rh | |
Ubushyuhe n'ububiko | -20 ℃ -60 ℃, munsi ya 70% rh | |
Urwego rwo Kurinda | IP65 (funga urubanza) | |
Kurinda birenze urugero | Gupima kurwanya isi: hagati ya buri intera ya C (H) -E,P (S) -ES, AC 280V / amasegonda 3 | |
Kurwanya Kurwanya | Kurenga 20MΩ (hagati yumuzingi nigikonoshwa cyo hanze ni 500V) | |
Kurwanya Umuvuduko | AC 3700V / rms.(Hagati yumuzingi nigikonoshwa cyo hanze) | |
Ibiranga amashanyarazi | IEC61326 (EMC) | |
Ubwoko bwo Kurinda | IEC61010-1 (CAT Ⅲ 300V,CAT IV 150V,Umwanda 2); IEC61010-031; IEC61557-1 (Kurwanya isi); IEC61557-5 (Kurwanya Ubutaka); JJG 366-2004 (Metero yo guhangana) JJG 1054-2009 (Clamp grounding resistance metero) |