GDDO-20C AC / DC Igikoresho cya Calibration Igikoresho
GDDO-20C AC / DC Igikoresho cya Electric Meter Calibration Device ikoreshwa mugutahura ikosa ryibanze ryibikoresho bitandukanye byamashanyarazi yumuriro wamashanyarazi, harimo voltmeter, ammeter, wattmeter, ohmmeter, icyiciro kimwe & metero eshatu za AC ingufu za metero (kubishaka) hamwe nikosa ryibanze rya DC volt-metero na ammeter.
Ku gice cya metero, bisaba imbaraga zuzuye zumurongo wa AC ikusanya nkikoranabuhanga ryibanze, rigizwe nogutunganya ibimenyetso bya digitale (DSP) hamwe nimibare 16 yihuta yihuta-igereranya;Ku nkomoko y'ibimenyetso, ikoresha DSP na 16-yihuta yihuta igereranya-igizwe na digitale kugirango ikore isoko yerekana ibimenyetso bitanga ibimenyetso bya sine na signal yo kugoreka.
●Icyiciro cyukuri cya 0.05.Iyo amashanyarazi ya AC, ingufu za AC nimbaraga zipimye, igikoresho gifite ibikoresho bya digitale / inshuro nyinshi (DFC) hamwe numurongo wakazi urenga 60kHz hamwe nintera nyinshi zigezweho, kubwibyo byemezwa neza.
●Umuhengeri wo kugoreka inshuro 2 ~ 31, umubare, inshuro na amplitude yo guhuza, hamwe nicyiciro cyo guhuza umurongo wibanze urashobora gutegurwa byose.
●Ibara rya 6.5-inimero ya TFT LCD, isobanutse kandi yerekana neza.
●Hamwe nicyambu cya RS232.
●Hamwe nubushobozi bunini bwo kwibuka butahindagurika, burashobora kubika ibisubizo byikizamini cya metero 300 munsi yikizamini, gushyigikira amakuru yo kureba hamwe nibikorwa byo kohereza amakuru.
●Hamwe no kwizerwa kwiza, byoroshye gukora.
Imbaraga zumuriro AC zisohoka | |
Umuvuduko w'amashanyarazi (V) | 50, 100, 200, 400, 600 (800V birashoboka), Mak.ubushobozi bwo gusohora 20VA |
Urwego rugezweho (A) | 0.5, 1, 2.5, 5, 10, 20, Mak.ubushobozi bwo gusohora 20VA |
Umwanya wo guhinduranya ingufu | 0 ~ 130%, guhindura neza 5 * 10 |
Urwego rwo guhindura ibintu | 0 ~ 130%, guhindura neza 5 * 10 |
Ukuri kwa voltage, imbaraga, imbaraga nimbaraga | 0,05% |
Ububasha bwimbaraga nimbaraga | 0.1% |
Icyiciro cyukuri cyumuyaga kugeza icyiciro cya voltage | 0.05 ° |
Inshuro | Urwego rwo guhindura: 45 ~ 65Hz, Guhindura neza: 0.001Hz Gushiraho agaciro nyako: 0.01Hz |
Icyiciro | Urwego rwo guhindura: 0 ~ 359.99 ° Guhindura neza: 0.01 ° Gushiraho agaciro nyako: 0.05 ° |
Urwego rwo kugoreka rwa voltage hamwe nibisohoka byahindutse | ≤0.3% |
Ihinduka rya voltage, ikigezweho nimbaraga zisohoka | ≤0.01% / 60s (agaciro-hejuru) |
Harmonics | Inshuro 2 ~ 31 Amplitude: 0 ~ 20% Icyiciro cyiza: 0.01 ° * N (“N” bivuga gahunda ihuza) |
DC ibisohoka | |
Umuvuduko w'amashanyarazi (V) | 0.075, 75, 150, 300, 500, 1000, Mak.ubushobozi bwo gusohora 20W |
Urwego rugezweho (A) | 0.5, 1, 2.5, 5, 10, 20, Mak.ubushobozi bwo gusohora 20W |
Guhindura urwego rwa voltage nubu | 0 ~ 120% (utabariyemo 1000V), guhindura neza 5 * 10 |
Guhagarara kwa voltage nibisohoka | ≤0.01% / 60s (agaciro-hejuru) |
Ukuri kwa voltage gushiraho agaciro | 0,05% |
Ukuri kugiciro cyagenwe | 0.1% |
Ibisobanuro kuri 75mV bisohoka (Umutwaro ≥5Ω) | 0.1% |
Ibipimo rusange | |
Amashanyarazi | Icyiciro kimwe 220V ± 10%, 50Hz ± 5% |
Koresha ibisabwa | 20 ℃ ± 10 ℃, 85% RH |
Igipimo | 460 * 460 * 175mm |
Ibiro | Hafi 20kg |
Main | 1 set |
Aluminiumalloy box | 1 set |
Umugozi w'amashanyarazi | 1 pc |
Test umurongo hamwe nu muhuza | 1 pc |
Umurongo w'ikizamini (DC 75mV) | 1 pc |
Umurongo wikizamini cyingufu zamashanyarazi | 1 pc |
Umugozi w'itumanaho | 1 pc |
Pamashanyarazi | 1 pc |
Umukoresha 'Ubuyobozi | Kopi 1 |
Raporo y'ibizamini by'uruganda | Kopi 1 |