GDF-3000 DC Sisitemu Yisi Ikosa
Muri sisitemu ya DC, hariho amakosa menshi yisi arimo amakosa yisi ataziguye, ikosa ryisi ridafite ibyuma, ikosa ryisi, ikosa ryiza nubutaka bwiza, ikosa ryiza nisi ribi, ikosa ryisi.GDF-3000 Igeragezwa ryisi ya sisitemu ya DC ishakisha amakosa yisi kandi ikerekana ibipimo bya voltage ya sisitemu, voltage yisi, kurwanya isi hamwe nubutaka bwamashami neza.
●Imikorere yo gupima amashanyarazi ya sisitemu yubutaka, igikoresho gishobora gupima sisitemu yubutaka bwa sisitemu, itari nziza kuri voltage yubutaka, voltage ya sisitemu, irashobora kugera kuri 0-300V ikurikirana.
●Imikorere yo gupima inzitizi ya sisitemu, igikoresho kirashobora gupima ibyiza kubutaka bwubutaka hamwe nibibi biterwa nubutaka bwa sisitemu.Irashobora kumenya gupima 0-999KΩ.
●Imikorere ya AC umugozi w'amashanyarazi, igikoresho gishobora gucira imanza amashanyarazi ya AC muri sisitemu ya DC, kandi irashobora gupima agaciro k'umubyigano wa AC winjiye muri sisitemu ya DC, urugero rwa AC voltage ni 0-280V.
●Igikorwa cyo gupima ishami ryimikorere.Igikoresho gipima inzitizi nziza kandi mbi ya buri shami.
●Igikorwa cyo gushinga amashami umwanya uhagaze, igikoresho kirashobora kugera kumikorere yibibanza byerekana imikorere yibikorwa byishami.
●Imikorere ya Ammeter, igikoresho gishobora gukoreshwa nka ammeter-yuzuye neza, kandi ibipimo byo gupima birashobora kugera kuri 0.01mA.
●Hamwe nimikorere yubushakashatsi butari ikimenyetso, igikoresho gishobora kumenya aho ikosa ryatewe nta gutera ikimenyetso icyo ari cyo cyose muri sisitemu.
●Icyerekezo cyerekana imikorere, yo kugerageza ishami hamwe nubutaka bwerekana, igikoresho kizaba gifite icyerekezo cyerekana umwambi kugirango werekane icyerekezo kigereranyo kiri hagati yumukoresha wahantu hamwe n’ahantu habonetse, kugirango tunonosore neza.
●Igikorwa cyo gusesengura ibikorwa, mugihe ukoresheje imikorere yubutaka, nyuma yo kubona ishami, detector izerekana indangagaciro yishami ryishami kugirango ikoreshwe nisesengura.
●Imikorere ya curveform yerekana imikorere, mugihe ukoresheje detector kugirango umenye imiterere yimiterere yishami ryageragejwe, kwerekana bizerekana impinduka zubu zishami ryapimwe muburyo bwumurongo wikurikiranya, byorohereza uyikoresha kubona vuba kandi neza. Ingingo.
●Microcontroller yatumijwe mu mahanga ikoreshwa nka sisitemu nkuru.Igishushanyo mbonera cyibikoresho bihuye neza nuburinganire bujyanye nimbaraga na electronique.Uburyo bwinshi bwo kurengerwa bwakoreshejwe imbere kugirango hamenyekane neza igikoresho nigikoresho kiri mu kizamini.
●Metero yuzuye ya DC clamp ikoreshwa nkigice cyo kugura ibimenyetso, kandi icyitegererezo cya voltage gifata ibyuma bisobanutse neza bigereranywa na digitale, kandi voltage na impedance byapimwe neza.
●LCD yerekana, hamwe ninshuti yinshuti, isobanutse kandi yoroshye gukora.Erekana indangagaciro yerekana neza kandi nyayo-yerekana kwerekana imiterere.Irerekana urwego rwimikorere ya buri shami nicyerekezo cyikosa ryisi.
●Sisitemu yo kumenya no kumenya ubwenge.
●"Umusesenguzi" arashobora guhita amenya urwego rwa voltage ya sisitemu, kandi akerekana amakuru yimbogamizi yihuse mugihe inzitizi ya sisitemu ihinduka.
●Nyuma ya detector ihujwe namakuru yisesengura, ntabwo ihindurwa nintera yo kumenya;
●Iyo "detector" iri kugenzura, clamp irashobora gufunga umugozi umwe w'amashanyarazi, cyangwa gufunga insinga nyinshi z'amashanyarazi kugirango tunonosore imikorere;
●Nyuma yikizamini cya "detector" kirangiye, niba ishami ryapimwe rifite amakosa yo gukumira, amakuru yicyerekezo cyikosa ugereranije nikizamini.
●Module yohereza amakuru idafite umugozi yubatswe hagati ya "analyseur" na "detector" kugirango itumanaho, kandi imikorere yikizamini hamwe namakuru yerekana yuzuye, kandi irashobora gukemura ibibazo bitandukanye byatewe na sisitemu ya DC.
●Igikoresho kirashobora kumenya aho ikosa ritangirira utinjije ibimenyetso muri sisitemu ya DC.Muburyo bwibimenyetso, igikoresho gifite imipaka igabanya na voltage igabanya module, idafite ingaruka kuri sisitemu ya DC.
Koresha Ibidukikije | |
Ubushyuhe bwibidukikije | -30 ° C ~ +50 ° C; |
Ubushuhe bugereranije | ≤95%; |
Ibipimo bya tekinoroji itumanaho | |
Imbaraga z'ikimenyetso | D 10dbm; |
Itsinda ryibimenyetso | 433Mhz; |
Ibyiyumvo | -106dBm; |
Intera yoherejwe | mugihe cyumurongo-wo-kureba, intera yizewe ya metero 250 uvuye kubutaka metero 2 |
Isesengura ibipimo bya tekiniki | |
Ikoreshwa rya DC sisitemu ya voltage urwego | 24V (yihariye), 48V, 110V, 220V cyangwa urwego rwumukoresha wagenwe |
Sisitemu nziza kandi mbi yo gupima voltage | 0-300V |
Ibipimo bya DC bipima kubutaka | 0-300V |
AC urukurikirane rw'amashanyarazi yananiwe gutambuka | 5V |
Gukemura ibipimo bya voltage | 0.1V |
Sisitemu yo gupima ibipimo byo kurwanya | 0—999.9KΩ |
Impamvu yo kurwanya ibipimo byo gupima | 0.1KΩ |
Uburyo bwo kwerekana | LCD |
Ikimenyetso cyo kumenya ingano | 0-2mA irashobora guhinduka |
Kumenyekanisha ibimenyetso bya voltage amplitude | 0-50V irashobora guhinduka |
Inshuro yikimenyetso | nta buryo bwa signal na 0.16Hz bidashoboka |
Sisitemu irwanya DC yagabanije ubushobozi bwa interineti | 1000uF |
Ibipimo bya tekiniki | |
Kurwanya insulation irwanya urwego rwamashami muburyo bwa signal | |
Igipimo cya voltage ya sisitemu ni 220V | 0 -600KΩ |
Igipimo cya voltage ya sisitemu ni 110V | 0 -300KΩ |
Igipimo cya voltage ya sisitemu ni 48V | 0 -60KΩ |
Igipimo cya voltage ya sisitemu ni 24V | 0 -20KΩ |
Gukemura ibipimo byo gukumira | 0.1KΩ |
Kurwanya insulasiyo yerekana urwego rwumuzunguruko nta kimenyetso cyerekana | |
Igipimo cya voltage ya sisitemu ni 220V | 0 -50KΩ |
Igipimo cya voltage ya sisitemu ni 110V | 0 -25KΩ |
Igipimo cya voltage ya sisitemu ni 48V | 0 -10KΩ |
Igipimo cya voltage ya sisitemu ni 24V | 0 -5KΩ |
Gukemura ibipimo byo gukumira | 0.1KΩ |
Umuhengeri wo kwerekana igihe | Amasegonda 12 |
Ikigereranyo cyo gupima | ± 100mA |
Icyemezo cyo gupima | 0.01mA |
Uburyo bwo kwerekana | LCD |
Uburyo bwo kwerekana icyerekezo | icyerekezo kimwe cyangwa gitandukanye |
Anti-DC sisitemu ishami ryo gukwirakwiza ubushobozi bwo kwivanga | 100uF |
Intera yo gukoresha hamwe nisesengura | nta ntera ntarengwa |
Ingano y'urwasaya | Diameter 30mm |
Detector | 1 pc |
Isesengura | 1 pc |
Adapt | 2 pc |
Clamp y'ubu | 1 pc |
Ikizamini(hamwe n'ingofero y'ingona) | 1 pc |
Carry | 1pc |
Umukoresha's Ubuyobozi | 1 pc |
Raporo y'Ikizamini cy'Uruganda | 1 pc |