GDF-3000A DC Sisitemu Isi Ikosa
Ikosa rya sisitemu ya DC, amakosa ya DC hamwe no kunanirwa kwa AC ni amakosa akunda kubaho kandi yangiza sisitemu y'amashanyarazi, kandi abangamira imikorere isanzwe ya sisitemu y'amashanyarazi.
Kugirango dufashe neza abakozi bashinzwe kubungabunga umurima kubona vuba na neza amakosa ya DC, isosiyete yacu yateje imbere DC ishakisha amakosa kubwimyaka myinshi kandi ikusanya incamake yuburambe.
Umushakashatsi wa DC wubutaka akoresha metero ndende-yuzuye ya clamp metero kugirango amenye kandi amenye amakosa akoresheje itandukaniro rya DC iri mumatongo.Tekinoroji yihuse ya FFT yinjijwe mubikoresho byo gushakisha amakosa ya DC, kugirango hamenyekane ubwoko butandukanye bwamakosa yo gukumira, amakosa ya DC, hamwe na AC yamashanyarazi muri sisitemu ya DC ifite urwego rutandukanye rwa voltage (24V (bidashoboka), 48V, 110V, 220V).
Hamwe nibisabwa byiyongera kubikorwa byimikorere ya sisitemu yingufu, ibisabwa muburyo butandukanye bwa DC gushakisha amakosa muri sisitemu yamashanyarazi nabyo bizaba byinshi kandi hejuru.Kubwibyo, ibisobanuro-bihanitse, isesengura ryibikorwa bizahinduka ibisabwa byibanze byigikoresho cya sisitemu nshya yamashanyarazi DC ishakisha.
.
.
.
(4) Sisitemu yagabanijwe imikorere yo gupima ubushobozi, igikoresho gishobora gupima ubushobozi bwagabanijwe bwa sisitemu no kwerekana mugihe nyacyo;
. gushakisha ikosa ryumurongo wimpeta;
.
.
.
.
(10) Umuhengeri wo kwerekana umurongo no kwerekana icyerekezo cyo kwerekana.Mugihe ukoresheje detector kugirango umenye ishami ryapimwe, bizerekana impinduka zubu zishami ryapimwe muburyo bwumurongo wikizunguruka kuri ecran, bikaba byoroheye uyikoresha kumenya neza ikosa ryihuse kandi neza.Shakisha icyerekezo cyamakosa mugihe hari ikosa ryimpeta nubutaka.
●Igishushanyo cyizewe cyane
Igikoresho gikoresha microcontroller yatumijwe mu mahanga nka sisitemu nyamukuru, kandi igishushanyo mbonera gikurikiza cyane imbaraga hamwe na electromagnetic ihuza ibipimo bijyanye.Uburyo bwimbere bwimbere bwakoreshejwe kugirango hamenyekane neza igikoresho nigikoresho kiri mu kizamini.
●Guhitamo ibikoresho neza
Igikoresho gifata icyegeranyo cyiza cyane nkigice cyo kugura ibimenyetso, kandi icyitegererezo cya voltage gifata ibyuma bisobanutse bitumizwa mu mahanga bigereranywa na digitale ihinduranya chip, voltage na impedance bipimwa neza;
●Imikorere yabantu-mudasobwa
Byombi abasesengura na detector bakoresha TFT y'amazi ya kirisiti yerekana abakoresha kugirango babone amakuru;
Igikorwa kiroroshye kandi cyihuse, kandi mugihe kumenya amashami atandukanye bigaragaye, buto imwe yo gutangira irashobora kurangira;
Ibisubizo byikizamini biroroshye kandi ibisubizo byikizamini birashobora kwerekanwa kubakoresha muburyo butandukanye bwo kwerekana, harimo guhagarara cyangwa kudahinduka, urwego rwo gukumira, kurwanya izirinda, kumeneka, hamwe namakuru yerekanwe.
●Sisitemu yo kumenya no kumenya ubwenge
Isesengura ihita imenya urwego rwa voltage urwego;
Isesengura rishobora kumenya icyiciro cyamakosa;
Nyuma yo gushakisha no gusesengura amakuru amaze guhuzwa rimwe, ntabwo bizaterwa nintera yo kumenya;
Iyo disiketi iri kugenzura, uwakusanyije arashobora gufunga umugozi umwe cyangwa gufunga insinga nyinshi kugirango arusheho gukora neza;
Nyuma yikizamini cya detector kirangiye, niba ishami ryapimwe rifite umuyoboro wimpeta cyangwa ikosa rya insulasiyo, amakuru yicyerekezo cyikosa ugereranije nikizamini cyagenwe.
●Igikorwa cyuzuye cyo kugerageza nubushobozi bwo gukemura amakosa
Modire yohereza amakuru idafite umugozi yubatswe hagati yisesengura na detector yo gutumanaho.Imikorere yikizamini no kwerekana amakuru yuzuye, kandi irashobora guhangana numuyoboro utandukanye wimpeta hamwe namakosa yo kubika muri sisitemu ya DC.
Isesengura rifite uburyo butandukanye bwo gukora bukoreshwa muguhitamo imikorere ya "Amplitude Modulation", "Waveform" na "Mode", ishobora guhuza nibikorwa bitandukanye bigoye.
●Umutekano muke
Igikoresho gikoresha ibimenyetso bya micro-amplitude yo gutahura hamwe n’ibisubizo bihanitse bya DC bimenyekanisha kugirango bamenye amakosa kandi bihagarare, kandi nta ngaruka bigira kuri sisitemu ya DC.
Ibisobanuro bya Analyser | |
Umuvuduko w'akazi | DC 22-300V. |
Ubushyuhe bwibidukikije | -20 ℃ —55 ℃ |
Ubushuhe bugereranije | 0-90% |
Ibipimo bya voltage | |
Ingano yo gupima DC | 22-300V |
Ikigereranyo cyo gupima ingufu za DC | 0.1V |
DC ibipimo byo gupima neza | ± 0.5%@ 220V DC itanga amashanyarazi (180V-286V) @ 110V DC itanga amashanyarazi (90V-143V) |
Ibipimo bya voltage | |
Ibipimo AC na DCumugozivoltage | 10-280v |
Ikigereranyo cyo gupima AC voltage | 0.1V |
Ibipimo bya AC voltage | 0.5% |
Ibipimo byo kurwanya insulation | |
Ikigereranyo cyo kurwanya insulation | 0-999.9KΩ |
Gukemura ibipimo byo gukumira | 0.1KΩ |
Ibipimo byo kurwanya insulation | ≤ ± 5%Ri <10KΩKugaragazaagaciro kihariye 10KΩ≤Ri≤500KΩ±5% |
Menya ikiraro cya amplitude yo kugereranya | 0mA, 0.25mA, 0.5mA, 1mA, 2mA |
Menya intera irwanya impeta | munsi ya 50KΩ |
Sisitemu yagabanijwe gupima ubushobozi | |
Sisitemu yagabanije ubushobozi bwo gupima | 0-999.9uFubunyangamugayo C <10uF cyangwa C> 200uF: kwerekana agaciro kihariye;10uF≤C≤200uF:±10% cyangwa±3uF; Gutahura ubwoko bwimiterere yo guhitamo: Umuhengeri wa sine, umurongo wa kare; |
Ibipimo byo kurwanya sisitemu | 0-1000kΩ |
Gutahura ubwoko bwimiterere yo guhitamo | sine wave, kare kare |
Uburyo bwo gukora | guhatira ibimenyetso gutangira, gutangiza ibimenyetso byikora |
Erekana itangazamakuru nicyemezo | TFT, 320x240 |
Ibisobanuro bya Detector | |
Ibipimo byo kurwanya insulation | |
Ikigereranyo cyo kurwanya insulation | 0-500KΩ |
Gukemura ibipimo byo gukumira | 0.1KΩ |
Ibipimo byo kurwanya insulation | Ri <10KΩKugaragazaagaciro kihariye 10KΩ≤Ri≤500KΩ±10% |
Urutonde rwisesengura | |
Umubare wimiyoboro yisesengura | 1 |
Isesengura rya Spectrum inshuro zingana | 0.125-12.5Hz |
Gukemura inshuro | 0.125Hz |
Igihe cyerekana imiterere | 8s; |
Kugaburira ibiryo bigezweho | 0-2A; |
Ikigereranyo cyo gupima | -100- + 100mA; |
Icyemezo cyo gupima | 0.01 mA |
Erekana itangazamakuru nicyemezo | TFT, 320x240 |
Ibipimo bya tekinoroji itumanaho | |
Igipimo | 2Mbps, kubera ko igihe cyo kohereza ikirere ari gito cyane, ibintu byo kugongana mugukwirakwiza simusiga biragabanuka cyane. |
Ingingo nyinshi | Ingingo ya 125 yumurongo, yujuje ibyifuzo byitumanaho ryingingo nyinshi no gutumanaho inshuro nyinshi |
Ultra-nto | yubatswe muri antenne ya 2.4GHz, ubunini buto, 15x29mm |
Gukoresha ingufu nke | Mugihe ukora muburyo bwo gusubiza, kwihuta kwikirere no gutangira umwanya bigabanya cyane ibyo ukoresha |
Detector | 1 pc |
Isesengura | 1 pc |
Adapt | 2 pc |
Clamp y'ubu | 1 pc |
Ikizamini(hamwe n'ingofero y'ingona) | 1 pc |
Carry | 1pc |
Umukoresha's Ubuyobozi | 1 pc |
Raporo y'Ikizamini cy'Uruganda | 1 pc |