GDFJ-VI Transformer Yasesekaye Gasesengura Gaz
GDFJ-VI Transformer Yasesekaye Gazi Isesengura ni gazi ya chromatografi yimukanwa ikwiranye nisesengura ryihuse.Ihuza chromatografique yo kumenya, gusesengura no gusuzuma muri imwe, kimwe na micro detector, isoko ya gaze ntoya hamwe na mudasobwa ikora kuri ecran.Ifite ihuzwa ryinshi, ituze ryiza, imiterere yoroshye kandi ikora neza kuruta amavuta ya chromatografiya gakondo.Isesengura kurubuga rishobora gusesengura mugihe no gusuzuma imiterere yimiterere ya transformateur, bigatuma imbaraga zakazi zoroha kandi byoroshye.Igikoresho gikoresha uburyo bwa kera-butatu, kandi amakuru yisesengura arasa naya laboratoire gakondo ya chromatografi.Igikoresho gikoresha icyerekezo gito giteye igishushanyo mbonera.Ifite kwishyira hamwe kwinshi, ingano ntoya nuburemere bworoshye, byoroshye gutwara kurubuga kugirango bisesengurwe.Itanga amakuru ku gihe kandi yukuri yo kugenzura no kugerageza guhindura, kandi ikiza abakozi benshi nubutunzi.
Isesengura ryuzuye ryibiri mu bice birindwi bya gaze H.2, CO, CO2, CH4, C.2H4, C.2H6, C.2H2.Ikigereranyo ntarengwa cyo kumenya acetylene ni 0.1ppm, kandi cyakoreshejwe neza mu nganda n’amashami menshi nk’amasosiyete atanga amashanyarazi, inganda z’amashanyarazi, inganda zihindura amashanyarazi, inganda nini zashonga, hamwe n’ibice bitanga amashanyarazi.
●Yubatswe muri ecran ya tekinoroji irwanya kugenzura kugirango igaragaze amashusho yerekana ingufu z'umuyaga.
Umuvuduko mwuka wose werekanwa muburyo bwa digitale.Umuvuduko wa gazi itwara, gaze ya hydrogène numwuka birashobora gusomwa biturutse kumurimo wakazi, kandi isesengura rishobora gufatwa mugihe nyacyo.
●Gukoresha ecran ya anti-kugenzura ikoranabuhanga kugirango ugere kubushyuhe bwibikoresho, kwerekana nibindi bikorwa.
Ibipimo by'ubushyuhe byose birashobora kwerekanwa muburyo bwa digitale.Ubushyuhe bwinkingi agasanduku, detector hamwe nuwivugurura birashobora gusomwa no kugenzurwa neza nakazi.Igikorwa kiroroshye kandi kirasobanutse.
●Kora kuri ecran kanda kugirango urangize gushyushya, gukonjesha, gutwika hamwe nuburyo bugezweho.
Igikoresho cyubatswe mu buryo bwikora bwo kugenzura ikirere gihita gikuraho igice cyumwuka mugihe gikora kuri ecran yo gukoraho, kugirango igipimo cya hydrogène nikirere kigere ku kigereranyo gikwiye gutwikwa, kandi kigarura igipimo nyuma yo gutwika kirangiye mu buryo bwikora;kimwe, unyuze mumadirishya yo gushiraho ikiraro muri software ikora irashobora kurangiza igenamigambi ryamazi yubushyuhe.
●Digital FID ya elegitoroniki ya zeru-tekinoroji kugirango yongere ubushobozi bwo kurwanya interineti.
Detector ya FID ikoresha tekinoroji ya zeru-igenamigambi hamwe na sisitemu yo mu rwego rwo hejuru kugira ngo yishyure ibyingenzi shingiro rya FID, kugirango tumenye uburyo bwa elegitoronike bwerekana ibimenyetso byerekana FID.Kuberako amabwiriza ya elegitoronike ashobora gushyirwaho muburyo butaziguye kumuyoboro wikimenyetso cyumuzunguruko kugirango uzamure ubushobozi bwo guhagarika urusaku rwa elegitoronike, nta kimenyetso kibangamira iyo potentiometero ya mashini ihujwe.Kubera kugabanya ibipimo bya parasitike, ifite ubushobozi bukomeye bwo kurwanya-kwivanga.
●Gukoresha mudasobwa irwanya kugenzura kugirango ugere ku kugenzura oscillator.
Binyuze kumurongo uhuza ibimenyetso, birashobora gutanga imbaraga kuri oscillator ntoya, kandi binyuze mumurimo wakazi, irashobora gukora inzira yose ya oscillator, nko gushyushya, gutangira kunyeganyega, guhagarara, guhuha byihuse kumpera, nibindi. Icyongereza n'Igishinwa, gishobora guhindurwa mu bwisanzure.
●Yubatswe muri pompe yumuyaga ucecetse, idafite isoko yo hanze.
Hamwe na pompe ntoya itumizwa mu mahanga imbere ya moteri nkuru, irashobora gutanga isoko yumwuka kubikoresho bidasubirwaho.Kubera igishushanyo mbonera, pompe yo mu kirere irashobora gukora bucece, kandi uyikoresha ntazumva ko ibaho.
●Igikorwa cyo gukingira gaze imikorere yumuriro wa tungsten wire.
Hamwe nibikorwa byubwenge bwo gukumira ubushyuhe bwumuriro, mugihe igitutu cya gaze yikigo kiri munsi yumutekano wumutekano, sisitemu izahita ihagarika amashanyarazi yumuriro kugirango irinde icyuma cyangiza ubushyuhe.
Ibigize | Min.gutahura |
H2 | 2 |
CO | 5 |
CO2 | 10 |
CH4 | 0.1 |
C2H4 | 0.1 |
C2H6 | 0.1 |
C2H2 | 0.1 |
FID (detector ya flame ionisation)
●Umupaka wo kumenya: Mt≤3 × 10-12g / s (Hexadecane / isooctane)
●Urusaku rw'ibanze: ≤5 × 10-14A
●Guhinduranya shingiro: ≤1 × 10-13A / 30min
●Urutonde rw'umurongo: ≥ 106
TCD (icyuma gipima ubushyuhe)
●Ibyiyumvo: S≥3500mV • ml / mg (bisanzwe);5000mV • ml / mg (byoroshye cyane)
●Urusaku rw'ibanze: ≤10μV
●Guhinduranya shingiro: ≤30μV / 30min
●Urutonde rw'umurongo: ≥104
Igipimo cyo kugenzura ubushyuhe
Igice cyo kugenzura ubushyuhe | Urwego | Ukuri |
Agasanduku | 4 ~ 450 ℃hejuru yubushyuhe bwicyumba | ± 0.1 ℃ |
Inkingi yatewe | 4 ~ 450 ℃hejuru yubushyuhe bwicyumba | ± 0.1 ℃ |
Ikimenyetso cya FID | 4 ~ 450 ℃hejuru yubushyuhe bwicyumba | ± 0.1 ℃ |
TCDDetector | 4 ~ 450 ℃hejuru yubushyuhe bwicyumba | ± 0.1 ℃ |
Ni nikel ivugururaer | 4 ~ 450 ℃hejuru yubushyuhe bwicyumba | ± 0.1 ℃ |
Abandi
Igipimo: 420 * 280 * 300mm
Uburemere: ˂15kg
Amashanyarazi: AC220V ± 10%, 50Hz
Oya. | Izina | Ibisobanuro | Qty. |
1 | Igendanwa DGA | GDFJ-VI | 1gushiraho |
2 | Ikibanza cya Chromatography | Gukwirakwiza amavuta yihariye | 1gushiraho |
3 | Miniature Yuzuye Oscillator | 1gushiraho | |
4 | Azote nziza | 2L, 99,999%, Aluminiyumu ivanze icupa | 2amacupa |
5 | Hydrogen nziza | 2L, 99,999%, Aluminiyumu ivanze icupa | 1icupa |
6 | Gazi isanzwe | 2L, 7 Ibigize, Aluminiyumu ivanze icupa | 1icupa |