GDHG-108A CT / PT Isesengura
GDHG-108A CT / PT Ikizamini gishyigikira uburyo bwo gupima voltage kugirango igerageze ibihuru CTs yashyizwe kuri transformateur cyangwa imbere yimashini zikoreshwa, bikwiranye na laboratoire no gutahura aho.
Itcan irashobora kuba byoroshye kandi byoroshye gukora voltage igezweho iranga, igipimo cya transformateur, igereranyo nikosa rya fonction angle, umutwaro wikizamini kuri CT / PT.
●Koresha ihame rya voltage yo gupima CT na PT.
●Kugira ngo wuzuze ibisabwa GB1207, GB1208, GB168-47 (IEC60044-1.6) nibindi bipimo.
●Nta bikoresho bifasha hanze, imashini imwe irashobora kuzuza ibintu byose byipimishije.
●Hamwe na printer yihuta ya micro printer: igihe-nyacyo cyo gusohora ibisubizo.
●Ukoresheje umugenzuzi wubwenge, imikorere iroroshye.
●5inch ya LCD yerekana.
●Mu buryo bwikora bwatanzwe CT / PT (kwishima) ivi ingingo agaciro.
●Imodoka yerekana 5% na 10% ikosa ryo kugabanuka.
●Bika amatsinda 3000 yamakuru, ntabwo azabura nyuma yumuriro.
●Icyambu cya USB.Amakuru arashobora kubikwa muri USB disiki hanyuma agasomwa na PC (dosiye yimiterere ya WORD).
●Uburemere bworoshye, munsi ya 22kg, bubereye kwipimisha kurubuga.
Ibikorwa by'ingenzi
CT(Kumenya voltage) | PT |
•VOltage Ibirangaumurongo (biranga umunezero) | •VOltage Ibirangaumurongo (biranga umunezero) |
•Bikora kubara ikivi agaciro | •Bikora kubara ikivi agaciro |
•Imodoka yerekana 5% na 10% ikosa ryo kugabanuka | •Guhindura ibipimo |
•Guhindura ibipimo | •Kwiyemeza ubuharike |
•Kwiyemeza ubuharike | •Ikizamini cya AC Hipot |
•Ikizamini cya AC Hipot | •Demagnetization icyuma |
•Demagnetization icyuma | • Umuvuduko mwinshi urashobora guhinduka (1.2-2.5times) muri PT VA ikizamini kiranga |
• Ibipimo ntarengwa (ALF) gupima |
Ibipimo nyamukuru
Ingingo | Parameter | |
Amashanyarazi | AC220V ± 10%, 50Hz | |
Ibisohoka | 0-1000Vrms(20A.impinga) | |
Ibipimo byo gupima ibyishimo | ≤ 0.4% yo gusoma + 0,6% y'urwego | |
CT ihindura ibipimo | Range | ≤3000A / 1A (15000A / 5A) |
Accuracy | ± 1.0% | |
PT ihindura ibipimo | Range | ≤500KV |
Accuracy | ± 1.0% | |
Ibidukikije | Ubushyuhe:-10 ℃ ~ 40 ℃, ubuhehere:≤ 90%, Uburebure:0001000m | |
Igipimo & Uburemere | Igipimo:440mm × 360mm × 340mmIbiro:≤22Kg |
Ikizamini cya CT / PT | Igice |
Ikizamini | 1set |
Umugozi w'isi | Igice |
Umugozi w'amashanyarazi | Igice |
2A fuse | 2pc |
Imfashanyigisho y'abakoresha | 1copy |
Raporo y'ibizamini by'uruganda | 1copy |