GDJB-1200A Icyiciro cya gatandatu Icyiciro cyo Kurinda Ikizamini
●Ibisohoka bigera kuri 6 -cyiciro cya voltage 6-icyiciro cyumuyaga, gishobora guhurizwa hamwe kugirango hamenyekane ibisanzwe 4 -cyiciro cya voltage 3 yicyiciro cyubwoko, icyiciro cya 6 cyubwoko bwa 6, ubwoko bwicyiciro cya 6, nuburyo bwo gusohora ibyiciro 12.
●Mudasobwa ikora cyane igizwe na mudasobwa igenzura inganda hamwe na 8.4-nini-nini-nini-nini-yerekana-amabara manini ya TFT yamazi ya kirisiti yerekana, ishobora gutanga amakuru akungahaye kandi yimbitse, harimo uko akazi kameze ubu, inama zakazi zikurikira hamwe namakuru atandukanye afasha;
●Ibisohoka bikoresha ubudahemuka buhanitse, bwizewe cyane modular umurongo wumurongo wimbaraga aho guhinduranya ubwoko bwimbaraga zongera imbaraga kugirango zikore neza.Ntabwo izabyara intera ndende kandi yohasi yivanga kurubuga rwibizamini, kandi bizemeza neza uburyo bwiza bwo guhinduranya neza kandi neza kuva kumuyoboro mwinshi kugeza muto.
●Igice gisohoka kigenzurwa na DSP, ifite umuvuduko wihuse wo kubara, imbaraga-nyayo-nyayo yo gutunganya ibimenyetso bya digitale, ubushobozi bwogukwirakwiza no gukemura cyane D / A guhinduka.Ibisohoka byahinduwe bifite ibisobanuro bihanitse, kugoreka gato no guhuza neza.Ifata umubare munini wa tekinoroji igezweho hamwe nibikoresho byuzuye, kandi ikora igishushanyo mbonera cyumwuga.Kubwibyo, igikoresho ni gito mubunini, urumuri muburemere, cyuzuye mumikorere, byoroshye gutwara, kandi birashobora gukoreshwa iyo utangiye, kandi ikizamini kiroroshye cyane.
●Irashobora kuzuza umubare munini munini munini wo kugenzura imirimo hamwe nurwego rwo hejuru rwo kwikora.Irashobora kugerageza byoroshye no gusikana ibice bitandukanye byo kurinda, gukora amakosa yo gukina, kubika amakuru yikizamini mugihe nyacyo, kwerekana ibishushanyo mbonera, no gusohora raporo kumurongo.
●Hano hari 110V na 220V byigenga byabigenewe bishobora guhindurwa ingufu za DC kugirango bigenzurwe.
●Igisekuru gishya GDJB-1200A yipimisha ifite ibikoresho byo gufungura inzira 10 no gufungura inzira 8, byoroshye kwipimisha wenyine.Iyinjiza ryinjira rihuza nubusa kandi 0 ~ 250V ishobora guhura, irashobora gushishoza kandi igahita imenyekana.
●Irashobora gukora imirimo itandukanye igoye, kandi irashobora kugerageza no gusikana byoroshye uburyo butandukanye bwo kurinda amakosa yo gukina.Bika amakuru yikizamini mugihe nyacyo, werekane ibishushanyo mbonera, raporo zanditse, nibindi.
●Imiterere yo gukwirakwiza ubushyuhe yateguwe mu buryo bushyize mu gaciro, ingamba zo kurinda ibyuma byizewe kandi biratunganye, kandi imbaraga zoroshye zo gutangira imbaraga, software yo kwisuzumisha hamwe nibikorwa byo guhagarika umusaruro biratangwa.
AC Ibisohoka | Icyiciro 6 (RMS) | 6 * 0 ~ 30A |
Icyiciro 3 (RMS) | 3 * 0 ~ 60A | |
Ibyiciro 6 bisa nibisohoka (RMS) | 0 ~ 180A | |
Byemerewe igihe kirekire cyo gukora agaciro k'icyiciro cya none (RMS) | 10A | |
Imbaraga zisohoka zicyiciro cyubu | 400VA | |
Emera amasaha y'akazi @ max.ibisohoka 6-icyiciro kibangikanye | 10s | |
Ukuri | ≤0.5A ± 2mA >0.5A 0.2% | |
Urutonde rwinshuro (Umuhengeri wibanze) | 0 ~ 1000Hz | |
Ibihe bihuje | Inshuro 0 ~ 20 | |
DC Ibisohoka | Ibisohoka | 0 ~ ± 10A / icyiciro;0 ~ ± 60A / 6-pahse ibangikanye |
Ukuri | 0.5% | |
Ibisohoka ntarengwa umutwaro wa voltage | 20V | |
Amashanyarazi ya AC | Icyiciro cya voltage gisohoka (RMS) | 0 ~ 120V Ukuri: 0.2% |
Umurongo wa voltage usohoka (RMS) | 0 ~ 240V | |
Icyiciro cya voltage / Umurongo wa voltage isohoka imbaraga | 80VA / 100VA | |
Urutonde rwinshuro (Umuhengeri wibanze) | 0 ~ 1000Hz | |
Ibihe bihuje | Inshuro 1 ~ 20 | |
DC Ibisohoka | Icyiciro cya voltage gisohoka amplitude | 0 ~ ± 160V Ukuri: 0.5% |
Umurongo wa voltage usohoka amplitude | 0 ~ ± 320V | |
Icyiciro cya voltage / Umurongo wa voltage isohoka imbaraga | 70VA / 140VA | |
Binary | Ibyinjijwe | Imiyoboro 10 |
Guhuza ubusa | 1 ~ 20mA, 24V | |
Birashoboka kuboneka | "0": 0 ~ + 6V;"1": +11 V ~ + 250 V. | |
Ibisohoka | 8 bibiri DC: 220 V / 0.2 A;AC: 220 V / 0.5 A. | |
Igihe cyo gupima | 0.1ms ~ 9999s Gupima ukuri: <0.1mS | |
Igipimo & Uburemere | 480 * 360 * 200mm³ 19kg |
Oya. | Izina | Ibisobanuro | Qty / Igice | Ishusho |
1 | Igice gikuru | GDJB-1200A | 1set |
|
2 | Fuse | 2A | 4ibice |
|
10A | 4ibice | |||
3 | Umugozi w'amashanyarazi |
| Igice 1 |
|
4 | Ikizamini | 0.5m (umutuku, umuhondo, icyatsi, umukara buri gice 2) | Ibice 8 |
|
5 | Ikigeragezo wire 4 intangiriro | Umukara (umutuku, umuhondo, icyatsi, umukara)-flat | Ibice 2 |
|
6 | Ikigeragezo wire 4 intangiriro | Umukara (umutuku, umuhondo, icyatsi, umukara)-umuzingi | Ibice 2 |
|
7 | Ikizamini | ubururu | Igice 1 |
|
8 | Ikizamini | (cyera, ikawa buri gice 1) | Ibice 2 | |
9 | Ikizamini | umutuku, icyatsi, umuhondo buri gice 1) | Ibice 3 | |
10 | Ikizamini | umukara | Ibice 2 | |
11 | Itumanahowire |
| Igice 1 |
|
14 | Ikizamini kinini | (umutuku, umuhondo, icyatsi, umukara buri gice 1) | Ibice 4 |
|
15 | Ikizamini gito | (umuhondo, icyatsi, buri bice 4) | Ibice 8 | |
16 | Ikizamini gito | (umutuku, umukara buri 5piece) | Ibice 10 | |
17 | Urugero | (umutuku, umuhondo, icyatsi, umukara buri bice 2) | Ibice 8 | |
18 | Urushinge | (umutuku, umuhondo, icyatsi, umukara buri bice 3) | Ibice 12 | |
19 | CD |
| Kopi 1 |
|
20 | QC pass | Mu Cyongereza | Kopi 1 |
|
21 | Igitabo | Mu Cyongereza | Kopi 1 |