GDJF-2007 Isesengura rya Digitale Igice
GDJF-2007 Isesengura rya Digital Partial Disharge Analyser ikoreshwa cyane mugushakisha isohoka ryigice cyibikoresho byumuvuduko mwinshi nka transformateur power, transformateur ibikoresho, icyuma cyangiza amashanyarazi, GIS, Zinc oxyde yo gufata, umugozi wamashanyarazi.Irashobora kandi gukora ibizamini byubwoko no gukurikirana imikorere yimikorere.
Harimo igice cyingenzi, software ya PD, transformateur yubu, igice cyinjiza, kalibrasi ya pulse generator, adaptate yinjiza, antenna amplifier na kabili ihuza nibindi.
●12inch LCD yerekana, hamwe nigishushanyo mbonera, cyoroshye kandi kiramba, byoroshye gukoresha.
●Ubushobozi bukomeye bwo kurwanya kwivanga, neza.Ukoresheje tekinoroji yo kuyungurura, guhuza umurima birashobora kuvaho neza, kandi gupima igice cyo gusohora bishobora kugerwaho mubidukikije bikomeye.
●Kwishakira amakuru menshi.Mugaragaza imwe irashobora kwerekana imiyoboro 2 cyangwa imiyoboro 4.
●Imikorere ikomeye ya software.Hamwe no gupima PD, gusesengura, PD inshuro nyinshi zo gusohora N gupima, gusesengura no kurwanya kwivanga, kurwanya-dinamike.Guhitamo kubuntu kuri ellipse, umurongo ugororotse hamwe na sinusoidal yerekana uburyo.Gupima no Kwitegereza gusohora impiswi ukoresheje idirishya, hamwe na voltage yikigereranyo hamwe nubu, gusohora igice birashobora gupimirwa icyarimwe.Ibizamini byose bya 2channels birashobora kubikwa mugihe gikwiye.Ikizamini cyikizamini gishobora gukizwa, kongera kwerekana no gusesengurwa.Inyungu zingana kuri buri muyoboro zirashobora guhinduka kandi zigahinduka neza.Idirishya rifungura tekinoroji, kugirango wirinde ingaruka zo kwivanga mubipimo.Icyiciro cyo gufungura idirishya, idirishya rimwe nidirishya rya kabiri birashobora guhitamo.Idirishya rishobora gufungurwa kubuntu muri 360degree.
●Byemewe na IEC60270 bisanzwe.
●Urwego rwubushobozi: 6pF-250μF
●Ibyiyumvo: 0.1pc
●Umuyoboro wo gupima: 2 cyangwa 4pcs imiyoboro yigenga
●Icyitegererezo cyukuri: 12Bit
●Igipimo cyicyitegererezo: Mak.100MHz kuri buri muyoboro
●Urwego rwo gupima: 0.1pc-10000nc.
●Urwego rudasanzwe:> 80db.
●Ibipimo byo gupima inshuro: 10kHz-1MHz kuri 3db.
●Inshuro zingufu zipimisha: 50-400Hz.
●Akayunguruzo
Umuvuduko muke: 10K, 20K, 40K, 80K;
Umuvuduko mwinshi: 100K, 200K, 300K, 1000K.
●Ubushyuhe bwibidukikije: -15 ℃ --50 ℃
●Ubushuhe bugereranije: ≤95% (20 ℃)
●Uburebure: 0003000m.
●Ubushobozi bwingaruka: 5000V kuri buri cyambu cyinjira hamwe nimbaraga zamashanyarazi (nziza, mbi na AC)
●Imbaraga zinjiza: AC220V ± 10%, 45-65Hz, imbaraga <500W.
●Uburemere: hafi 15kg.
●Igipimo: 58 * 36 * 32CM