GDJW-40B Ikizamini cya Wireless Insulator
GDJW-40B irashobora gukoreshwa mugupima voltage yo gukwirakwiza insulirateri yahagaritswe cyangwa laboratoire yo gutahura insulator ihagaritswe, kandi igashobora gutahura neza ibibazo byihishe imbere muri insulator, kunoza imikorere yimikorere ya sisitemu ya gride, no kunoza imikorere. imikorere myiza yabakozi kumurongo bakora ikizamini kizima.Iki gicuruzwa gikoresha itumanaho ridafite insinga, intera yitumanaho hagati ya detector na terefone ifashe intoki irashobora kugera kuri 100m hejuru, Kora inzira yo gupima rwose umutekano kandi wizewe, byihuse kandi byukuri.Mubyongeyeho, igikoresho gifite imbaraga zikomeye zo kurwanya-kwivanga, kubahiriza byuzuye (EMC) ibisabwa bisanzwe, guhuza nuburyo butandukanye bwo guhuza amashanyarazi.
●Gukoresha voltage: 35-1000KV, urwego rutandukanye rwa voltage rurakoreshwa.
●Ibipimo bipima urugero: 0-40kV (voltage idasanzwe irashobora gutegurwa).
●Ikosa ryo gupimwa: ≤ ± 1%.
●Igipimo cyicyitegererezo: inshuro 10 / S.
●Itariki yigihe igenamigambi: hindura itariki nigihe, kugirango byorohereze abakoresha gushakisha, kureba amateka yamateka.
●Igenamigambi ryinyuma-yumucyo: guhora urumuri, guhoraho, iminota 0-999 irashobora gushirwaho.
●Imashanyarazi yimodoka igenamiterere: ntanarimwe, iminota 0-999 irashobora gushirwaho.
●Intera yo kohereza intoki hamwe na detector ni m100m.
●Igishushanyo-cyuburyo bwinshi, imbaraga zikomeye, umutekano kurushaho kandi byoroshye.
●Igishushanyo mbonera rusange, ushoboze guhindura byoroshye icyerekezo cyo gupimwa ukurikije umwanya uhagarikwa wumugozi wa insulator.
●Kabiri ikingiwe, imbaraga zo kurwanya-kwivanga, zubahiriza byimazeyo ibipimo bya EMC.
●Imashini yihariye yimashini, yoroshye gukora.
Ikigereranyo cyo gupima ingufu | 0-40kV (voltage idasanzwe irashobora gutegurwa) |
Gupima ikosa | ± 1% |
Icyemezo | 0.01kV |
Igipimo cy'icyitegererezo | 10ibihe/S |
Ibikorwa bigezweho | 20120mA(Intoki zifashwe n'intoki),≤40mA(Detector) |
Amashanyarazi | 2*1.5VAA bateri yumye (Terminal ifashe intoki) 2*1.5VAAA bateri yumye (Detector) |
Igihe kirambye cyo gukora | ≥12h |
Intera yoherejwe | ≥100m (amashanyarazi ahagije) |
Erekana | LCD yerekana, irashobora kugaragara neza munsi yizuba. |
Ubushyuhe bwo gukora | -35 ℃ --- + 60 ℃ |
Ubushyuhe bwo kubika | -40 ℃ --- + 65 ℃ |
Ubushuhe bugereranije | ≤90%RH Non-condensate |
Oya. | Iboneza shingiro | Igice | Qty. | Ongera wibuke |
1 | Intoki | gushiraho | 1 | |
2 | Ikimenyetso cyabigenewe | igice | 1 | |
3 | A,B Detector | umuzi | 2 | |
4 | AA Bateri yumye (1.5V) | igice | 2 | |
7 | AAA Bateri yumye (1.5V) | igice | 2 | |
8 | Kuzana ibintu byoroshye | igice | 1 | |
9 | 220kV Inkoni | umuzi | 1 | ≤220kV guhuza na4ibice4M inkoni ya insulation,≥330kV guhuza na6 ibice6M inkoni |
10 | Imfashanyigisho | kopi | 1 | |
11 | Raporo y'ibizamini | kopi | 1 | |
12 | Ikarita ya garanti | kopi | 1 | |
13 | Urutonde | kopi | 1 |