Hano hari umubare munini wibikoresho byamashanyarazi muri sisitemu yingufu, sisitemu ya gari ya moshi hamwe n’ibirombe binini bya peteroli n’inganda n’inganda, ubwishingizi bw’imbere ni ubwinshi bwuzuye amavuta.Imbaraga za dielectric zo kubika amavuta nikizamini gisanzwe.Mu rwego rwo guhaza ibikenewe ku isoko, isosiyete yacu yateje imbere kandi ikora urukurikirane rw’ibizamini by’ingufu za dielectric y’amavuta ya dielectric dukurikije ibipimo bya IEC156 "Gukwirakwiza amavuta-kugena imbaraga za dielectric" hamwe n’inganda z’igihugu DL-474 · 4-92DL / T596 -1996 "Kode yikizamini cyo gukumira ibikoresho byamashanyarazi".
Iki gikoresho gifata microcomputer imwe-chip nkibyingenzi, ikamenya ibyikora byose byikizamini, ikagira ibipimo bihanitse byo gupima, itezimbere cyane akazi, kandi igabanya cyane imbaraga zumurimo w'abakozi.Igihe kimwe, igikoresho gifite isura yoroheje kandi yoroshye gutwara.
●Ifata microprocessor kugirango ihite irangiza ibikorwa byo kuzamura, gufata, gukurura, guhagarara, kubara, gucapa, nibindi, kandi irashobora gukora umuvuduko wamavuta kwihanganira ikizamini cya voltage murwego rwa 0-80 kV.
●Igikombe cyamavuta yicyo gikoresho gikozwe mugihe kimwe cyo guteramo ibirahuri bidasanzwe, birinda kwivanga nko kumeneka kwamavuta.
●Igishushanyo cyihariye cyo hejuru cyicyitegererezo cyibikoresho cyemerera agaciro kizamini kwinjira muri A / D ihindura mu buryo butaziguye, wirinda amakosa yatewe n’umuzunguruko, kandi bigatuma ibisubizo bipima neza.
●Ibipimo ngenderwaho byo gukora ibikoresho birimo amahame yinganda, amahame yigihugu n’ibipimo by’amahanga, kandi imikorere iroroshye kandi yoroshye.
●Hamwe na voltage irenze, irenze-iyindi, imipaka nubundi burinzi kugirango umutekano wabakora.Kandi ifite imbaraga zo kurwanya-kwivanga no guhuza amashanyarazi meza.
●Umuvuduko usohoka: 0-80kV
●Igipimo cyo kugoreka ingufu: <1%
●Ubushobozi: 1.5kVA
●Igikombe cyamavuta: 240ml
●Ibipimo bifatika: ± 3%
●Umuvuduko uriyongeraigipimo: 2kV / s, 3kV / s itabishaka, ikosa: 0.2kV / s
●Imbaraga zinjiza: AC220V ± 20%, 50Hz ± 5Hz
●Imbaraga: <200W
●Ubushyuhe bwo gukora: 0-40 ℃
●Ubushuhe: <85% RH
●Igipimo: 430 * 350 * 370mm
GDOT-80C igikoresho | Igice 1 |
Igikombe cyamavuta (250ml) | Igice 1 |
Umugozi w'amashanyarazi | Igice 1 |
Umugozi wubutaka | Igice 1 |
Fare fuse | Igice 2 |
Gukurura ibinyomoro | Igice 2 |
Bisanzwe 2.5mm | Igice 1 |
Tweezer | Igice 1 |
Shira impapuro | Umuzingo 1 |
Imfashanyigisho y'abakoresha | Kopi 1 |
Raporo y'ibizamini by'uruganda | Kopi 1 |
Ubundi electrode irahari