GDP-311IR SF6 Ikizamini Cyiza cya Gaz (Uburyo bwa IR)
GDP-311IR SF6 igerageza isuku ya gazi nigikoresho kigendanwa kurubuga rwa SF6 isuku ya gazi yakozwe na sosiyete yacu.Ihame rya infrarafarike ya SF6 isuzuma ibyuma byogukora isuku yakozwe na societe yuburayi Sensor ikoreshwa mugupima ubuziranenge bwa gaze ya SF6.Hamwe nibikoresho byumwuga hamwe na software nziza ya algorithms ya STMicroelectronics, twabyaye igisekuru gishya cya analyse ya gaz ya SF6.
●Isesengura ryubuziranenge bwibikoresho byamashanyarazi ya SF6 kumashanyarazi
●Ikizamini cya gazi ya SF6
●Ikizamini cyiza cya gaze ya SF6 yo kugarura no gukoresha
●Gukora gaze nziza
●Inganda zikoresha inganda zitanga gaze yumye
●Gukoresha ubushakashatsi niterambere
●Gusukura icyumba / kugenzura inzu yumye
●Ibicuruzwa byatumijwe mu mahanga bihanitse cyane hamwe na gahunda yo kwikorera-kalibrasi, menya neza kandi byizewe byamakuru yerekana neza umwaka wose.
●Inzira ya gazi yose hamwe nibikoresho bya polymer bihanitse, byemeza ko nta nkuta zamazi zimanikwa kandi byemeza umuvuduko wikizamini.
●Amavuta adafite amavuta adafite ibyuma-bigenga valve ikoreshwa kugirango hamenyekane neza agaciro gapimwe.
●Porogaramu igezweho ya algorithms itezimbere ikizamini cyukuri.
●Igikoresho cya chassis gihuriweho hamwe, abakoresha barashobora guhuza byoroshye ibikoresho bijyanye nibikoresho.Porogaramu rusange iratwarwa, ituma uyikoresha agira uburambe bwisanzuye.
●Ikizamini cyo gutangira, nta mpamvu yo kunyeganyega.
●Guhindura ubushyuhe no gukosora amakuru.
●Ubuhanga bwo kubara.
●Imbaraga za batiri ya lithium ikomeye, menya AC na DC amashanyarazi abiri.Nta mbaraga za AC zisabwa.Amashanyarazi ya Litiyumu akomeje gukora amasaha arenga 8 adakeneye amashanyarazi yo hanze.
●Kurwanya anti-electromagnetic intervention interineti kugirango igenzure ibicuruzwa byizewe.
●Ubushobozi bunini bwo kwibuka, bushobora kumenya ibice 1000 byimikorere yo kubika amakuru.
●Ibipimo byo gupima ubuziranenge ni 0.5% murwego rwose.Irashobora gukoreshwa mugupima gaze ya gaze ya SF6 hamwe na 70% ya gaze ya SF6.
●Ahantu heza hageragezwa herekana ko uyikoresha ashobora guhindura gazi muburyo bwihuse kandi vuba.Mugabanye igihe cyo gukora.
●Umwuka winjira wateguwe hamwe na miniature yo kwifungisha hamwe, kandi inzira yumwuka igomba kugeragezwa ntizisohoka mugihe inzira yumuyaga ihagaritswe.
●Irashobora kwagura itumanaho rya USB, itumanaho ryuruhererekane, module itumanaho ridafite umugozi, kandi ikamenya ibikorwa byitumanaho no gucapa mudasobwa yo hejuru.(bidashoboka)
●Imikorere ya gazi inzira yo kwitegura irashobora gukoreshwa mugusukura umuyoboro wikizamini mbere yimirimo yo gupima umurima, bigabanya igihe cyibizamini.(bidashoboka)
●Igikoresho gifite imikorere yo kugarura gaze yo kugarura gaze yo gupima sulfuru hexafluoride.Kurinda ibidukikije.(bidashoboka)
Uburyo bwo gupima | Ihame ryo gupima Infrared (sensor ya seriveri ya NDIR) |
Ibidukikije | -20 ℃ ~ + 60 ℃ |
Urwego rwo gupima | 0 ~ 100% SF6 |
Igihe cyo gusubiza | [90%] 60s |
Ukuri | ± 0.5% FS |
Gusubiramo | ± 0.5% |
Icyemezo | 0.01% |
Igice cyerekana | % |
Igipimo cya gazi | 400 ~ 600ml / min |
Igipimo cyerekana umuvuduko | 0 ~ 1000mL itumiza ibikoresho bya digitale |
Umuvuduko wa gaze yoroshye | ≤1MPa |
Ubushuhe bwibidukikije | 90% RH |
Ingano yo gupima | Nta ngaruka z'umuvuduko no gutemba |
Amashanyarazi | AC 220V ± 10%, Bateri 50Hz / DC Imbere irashobora gukora byibuze amasaha 8 |
Igipimo | 395 * 295 * 155mm |
Ibiro | hafi 2kg. |