GDPD-306M Igendanwa Ultrasonic Igice cyo Gusohora
GDPD-306M ikoreshwa cyane muburyo bwo gusohora igice cya sisitemu y'amashanyarazi.Harimo amashanyarazi maremare menshi, imiyoboro yimpeta, voltage / imashini ihindura, transformateur (ushizemo ubwoko bwumye), GIS, imirongo yo hejuru, insinga, nibindi bikoresho byerekana leta.
Ibipimo bikurikira bikoreshwa mugupima urugero rwo gusohora ibikoresho byamashanyarazi:
Kumenyekanisha igice cyo gusohora igice: Mugupima ibimenyetso bisohora mumashanyarazi yumurongo wumurongo, ubukana bwibisohoka igice burangwa ukurikije agaciro ntarengwa (dB) muburyo bukurikirana.
Kumenyekanisha igice cyo gusohora igice: Igikoresho gipima ibimenyetso byo gusohora mumashanyarazi yumurongo wumuriro, ikuramo impiswi zisohora kandi ikaranga inshuro zisohoka igice ukurikije umubare wibisohoka.
●Hamwe na sensor zitandukanye kugirango ugere kubice bimwe byerekana ibikoresho byamashanyarazi hafi ya byose.
●Tanga uburyo bwinshi bwo gusohora nkigihe-indangururamajwi, PRPD, PRPS, nibindi, kugirango umenye isesengura ryubwoko butandukanye bwo gusohora.
●Umukoresha-ukoresha-imashini yimashini yorohereza imicungire yamakuru yibikoresho bitandukanye, harimo no gukurikirana amateka yimihindagurikire yamateka, isesengura rya horizontal na vertical data, kandi ikamenya 360 ° isuzumabumenyi ryuzuye ryibikoresho byapimwe.
●Yubatswe muri sensor ya ultrasonic hamwe na voltage yigihe gito (nyuma yiswe TEV) sensor, irashobora kandi guhuzwa na sensor idasanzwe yo hanze ya transformateur, GIS, imirongo yo hejuru, hamwe ninsinga.
●Ifata uburyo bwo gutahura uburyo butagaragara, nta mpamvu yo kuzimya mugihe cyibizamini, nta mpamvu yo gushiraho andi masoko y’amashanyarazi menshi, biroroshye kuyakoresha kuruta gakondo ya pulsed igice gisohora ibintu.
●Ikizamini cyagutse ni 30kHz ~ 2.0GHz, kibereye amahame yo gutahura imirongo itandukanye.
Igipimo cya TEV | Igipimo cya UHF | ||
Igipimointera | 0-60dBmV | Itsinda ryerekana inshuro | 300 ~1500MHz |
Icyemezo | 1dB | Urwego rwo gupima | -75-0DBmV |
Ukuri | ± 1dB | Ukuri | <1dBmV |
Icyiza. impyisi kuri buri cyiciro | 1400 | Sensor yumurongo | 300-2000MHz |
Ibipimo byo gupima inshuro | 1~ 100MHz | ||
Igipimo cya AA | Ibipimo bya AE | ||
Urwego rwo gupima | -6dBμV ~ 68dBμV | Urwego rwo gupima | -6dBμV ~ 68dBμV |
Icyemezo | 1dB | Icyemezo | 1dB |
Ukuri | ± 1dB | Ukuri | ± 1dB |
Sensor center inshuro | 40kHz | Ikirangantego | 40-200kHz |
Ibipimo bya HFCT | |||
Sensor yohereza inzitizi | 5mV / mA | ||
Inshuro | 1 ~ 30MHz | ||
Ibyiyumvo | ≤50pC | ||
Ibyuma | |||
Igikonoshwa | ABS | ||
Erekana | 4.0inch ya RGB LCD ya ecran | ||
Controller | ARM | ||
Umuhuza | USB Imigaragarire (icyambu cya charger), Wireless WIFI 3.5mm stereo ya terefone jack, Wireless synchronisation igipimo Inyuma ya ultrasonic sensor yinjira | ||
Na terefone | 8ohm byibuze | ||
Ikarita ya SD | Bisanzwe 16G | ||
Bateri yubatswe | 3.7V /1Ah bateri | ||
Igihe cyo gukora | Ibyerekeye8amasaha | ||
Amashanyarazi | AC 90-264V cyangwa DC 5V | ||
Ubushyuhe bwo gukora | -20 ~ + 50℃ | ||
Ubushuhe | 20 ~ 85% ugereranije n'ubushuhe | ||
Igipimo, uburemere | 210 * 100 * 35 (mm), 0.4kg (igice nyamukuru) |
Igice nyamukuru | 1 | Standard |
External Twandikire ultrasonic sensor | 1 | Fcyangwa amahitamo, ikoreshwa kuri transformateur, GIS, moteri |
URukuruzi | 1 | Fcyangwa amahitamo, yakoreshejwe kuri GIS |
HFCT | 1 | Fcyangwa amahitamo, akoreshwa mumashanyarazi |
Tkabel | 1 | Standard |
Charger | 1 | Standard |
USB | 1 | Fcyangwa kwishyuza no gutumanaho PC |
Uumuyobozi wa ser | 1 | |
Fraporo y'ibizamini | 1 |