GDPD-414 Ikwirakwiza Igice cyo Gusohora



Main
igice
UHF sensor,
Ubwoko buzengurutse,bikwiranye na GIS
UHF sensor, ubwoko bwurukiramende, bubereye insinga z'amashanyarazi, transformateur, switchgear



HFCT, ibereye amashanyarazi, transformateur
Rukuruzi rwa TEV,
bikwiranye na switchgear
Ultrasonic sensor, ikwiranye na transformateur, switchgear

Hejuru y'amashusho ni kubanza gukoreshwa gusa.
Indege ya GDPD-414 (GDPD-414H)Irashobora guhuza byoroshye sensor zitandukanye ukurikije ibicuruzwa bitandukanye kugirango bipimwe.TEV, ultrasonic na HFCT birakwiriye gusohora igice cyo gutahura amashanyarazi menshi hamwe na kabine y'urusobe;Ultrasonic na UHF birakwiriye kumenya GIS;Ultrasonic na HFCT birakwiriye kugerageza insinga z'amashanyarazi.Sisitemu yo gusuzuma impuguke irashobora gusesengura amakuru yikizamini no gusuzuma ingufu zisohoka nibice bishoboka.Ikoreshwa cyane mumashanyarazi na gari ya moshi.

Ultrasonic na sensor ya TEV (2-muri-1)
●Emera umuvuduko mwinshi DSP / FPGA ikibaho cyicyitegererezo, imiyoboro 4 ihuza amakuru.
●Sisitemu ya software: isesengura rya software rishingiye kuri sisitemu yashyizwemo na ARM
●Imiyoboro ya 6/8/16 irashobora gushyirwaho
●8.1 santimetero cyangwa ikaye ya Thinkpad nkuko ubishaka
●6/8/16 imiyoboro irashobora gushyirwaho ukurikije ibyo umukiriya asabwa bitandukanye.
●Irashobora kwerekana ikarita ya PRPS na PRPD, igishushanyo cya ellipse, ikarita yerekana igipimo, ikarita ya QT, amakarita ya NT, amakarita ya PRPD, amakarita ya fai-QN ya buri muyoboro.
● Amabara atatu yerekana uburyo butukura, umuhondo nubururu byerekana ubukana bwo gusohora igice.
Umukiriya arashobora guhitamo sensor ukurikije ibintu byageragejwe bitandukanye:
Sensors | TEV/AE/HFCT | AE/UHF | AE/HFCT |
Ibintu Byageragejwe | HV Swichgear hamwe na kabili y'urusobekerane |
GIS |
Umugozi |
Ikimenyetso cya PD | |
CPU Inshuro zakazi | 1.2GHz / 800MHz |
Sisitemu y'imikorere | Linx yashyizwemo sisitemu y'imikorere |
Umuyoboro wicyuma | Umuyoboro wa LAN |
Umuyoboro udafite insinga | Yubatswe muri WiFi idafite umugozi (ubishaka) |
Sisitemu ikoresha ububiko | 1G / 512M |
Ububiko bwa sisitemu | 512M / 256M |
Inshuro yo gushaka amakuru | 250MHz / 80MHz |
Umuyoboro wa Ultrasonic | |
Urwego rwo gupima | 0-60mV |
Urwego rwo kumenya inshuro | 20 ~ 200kHz |
Umuyoboro wa UHF | |
Inshuro | 300 ~ 1800MHz / 300 ~ 1500MHz |
Urwego rwo gupima | -80 ~ 10dBm |
Ikosa | ± 1dBm |
Umwanzuro | 1dBm |
Umuyoboro wa HFCT | |
Ikirangantego | 0.5 ~ 100MHz |
Ikosa | ± 1dB |
Urwego rudasanzwe | 60dB |
Urwego rwo gupima | 0-100mV |
Ukuri | 1dB |
Umuyoboro wa TEV | |
Ikirangantego | 3 ~ 100MHz |
Ikosa | ± 1dB / mV |
Ibyiyumvo | 0.01mV |
Urwego rwo gupima | 0-60dB / mV |
Umwanzuro | 1dBm / mV |
Batteri | |
Bateri yubatswe | Batiri ya Litiyumu, 12V, 4400mAh / Batiri ya Litiyumu, 12V, 2000mAh |
Koresha igihe | amasaha agera kuri 8 / hafi amasaha 6 |
Igihe cyo kwishyuza | Amasaha agera kuri 2 |
Kurinda Bateri | Kurenza-voltage no kurinda birenze |
Amashanyarazi | |
Ikigereranyo cya voltage | 12.6V |
Kwishyuza ibyasohotse | 2A |
Ubushyuhe bwo gukora | -20 ℃ -60 ℃ |
Gukoresha ubuhehere | <80% |
GDPD-414H Ikiganza cyerekana intoki (urwego rwinganda) | |
CPU | Intel Quad Core Atom Z3735F |
GPU | Intel HD Igishushanyo (Gen7) |
Flash | 32GB |
RAM | 2GB |
Sisitemu y'imikorere | Windows10 |
Erekana | 8.1 inch 1280 × 800 IPS ya ecran |
Imigaragarire | Wifi na Bluetooth |
Batteri | 3.7V 8500mAH polymer lithium ion bateri |
Laptop ya Thinkpad cyangwa PC ya Tablet | |
Ingano | |
Ingano yimanza / PD kugura ingano yabakiriye | 395mm * 295mm * 105mm / 240mm * 165mm * 55mm |
Uburemere bwa PD | 3kg / 0,65kg |
Ingano ya PD hose / Kwerekana ubunini bwa tablet | 570mm * 360mm * 240mm / 395mm * 295mm * 105mm |
Erekana uburemere bwa tablet | 0,85 kg |
Muri rusange ingano yagasanduku | 570mm * 360mm * 240mm |
Ibidukikije | |
Ubushyuhe bwo gukora | -20 ℃ ~ 50 ℃ |
Ibidukikije | 0 ~ 90% RH |
Urwego rwa IP | 54 |
GDPD-414H Ikoresha Igice cyo Gusohora Igice