●Igikoresho nigikoresho cyibizamini bisobanutse neza bikoreshwa mugushakisha ibibazo byubuziranenge bwamashanyarazi nko kugoreka imivurungano, ibirimo guhuza hamwe no kutaringaniza ibyiciro bitatu mumashanyarazi.Ifite kandi imikorere yikigereranyo cyamashanyarazi hamwe nisesengura rya vector.
●Irashobora gupima neza voltage, ikigezweho, imbaraga zikora, imbaraga zidasanzwe, inguni yicyiciro, imbaraga zingufu, inshuro nibindi bikoresho byamashanyarazi.
●Irashobora kwerekana igishushanyo mbonera cya voltage yapimwe na voltage.Umukoresha arashobora gusesengura igishushanyo cya vector kugirango abone ukuri kwicyuma cyibikoresho bipima.
●Ibiriho bipimwa na clamp-ubwoko bwa transformateur.Operator ntabwo akeneye guhagarika ikizunguruka mugihe apimye hamwe na clamp yubwoko bwa clamp ya transformateur, gupima birashobora gukorwa neza kandi neza.Urutonde rutandukanye rwa clamps rushobora gutoranywa ukurikije ibipimo byabakoresha.
●Irashobora gupima no gusesengura ubuziranenge bwa AC butangwa na gride yingirakamaro kubakiriya.Irashobora gupima no gusesengura: gutandukana inshuro, gutandukana kwa voltage, ibyiciro bitatu bya voltage byemewe kutaringaniza hamwe na gride ihuza.
●Irashobora kwerekana icyiciro kimwe cya voltage hamwe nuburyo bugezweho kandi icyarimwe ikerekana ibyiciro bitatu byamashanyarazi hamwe nubu.
●Igeragezwa ryose rifite imikorere ya ecran yo korohereza abakoresha gusoma no gusesengura amakuru.
●Igenzura ry'imihindagurikire y'imizigo: Gupima no gusesengura ihindagurika ry'ibikoresho bitandukanye by'amashanyarazi biterwa n'ubwiza bw'amashanyarazi ya gride mu bihe bitandukanye.Igihe cyanditse kandi kibika inzira muri voltage, ikigezweho, imbaraga zikora, imbaraga zidasanzwe, imbaraga zigaragara, inshuro, icyiciro, nibindi bipimo byimbaraga.
●Gukurikirana neza kugenzura ibikoresho byamashanyarazi no guhindura imikorere kugirango bifashe abakoresha gukemura ibibazo murwego rwo guhindura ibikoresho byamashanyarazi no gutangiza.
●Ubushobozi bwo kugerageza no gusesengura ibipimo byingirakamaro byindishyi zingufu zidasanzwe hamwe nibikoresho byo kuyungurura muri sisitemu yingufu no gusuzuma umubare wimikorere n'ibipimo bya tekiniki.
●Irashobora gushiraho umwanya utandukanye wo kubika, gukomeza kubika amakuru ukurikije igihe cyagenwe;
●Yubatswe mububiko bunini bwububiko bwamakuru, irashobora kubikwa ubudahwema amezi arenga 18 mugihe cyiminota 1, ishobora guhura nibikenewe byigihe kirekire cyo kugenzura.
●Igikoresho gifite USB interineti, ishobora gukoporora byoroshye amakuru kuri mudasobwa icunga inyuma.
●Hamwe na software ikomeye yo gucunga amakuru, amakuru nyayo yatanzwe arashobora koherezwa muburyo butaziguye kuri mudasobwa yo gucunga inyuma kugirango birusheho gutunganywa kandi byihuse.
●Hamwe na kalendari ihoraho, imikorere yisaha, igihe-nyacyo cyo kwerekana itariki nigihe.Ikizamini cyibisubizo nibisubizo birashobora kubikwa icyarimwe, hanyuma bigashyirwa kuri mudasobwa binyuze ku cyambu gikurikirana, binyuze muri porogaramu yo gucunga inyuma (ku bushake) kugira ngo ugere ku micungire ya mudasobwa ya mudasobwa, hamwe n'ubushobozi bukomeye bwo gutanga raporo.
●Ifata LCD nini-nini nkiyerekanwa, Imikorere yicyongereza hamwe na LCD yerekana intera hamwe nicyongereza inyuguti yihuse amakuru hamwe nibintu byinshi byerekana.Imigaragarire yumuntu-imashini irangwa ninshuti.
●Iminota 3 nta gikorwa LCD yerekana ihita yinjira muburyo bwo kuzigama ingufu, kugirango ubuzima bwa bateri bwiyongere.
●Akabuto ka silicone kayobora, umva neza, ubuzima burebure, igishushanyo mbonera, cyoroshye gukora.
●Yubatswe mubushobozi buhanitse, ikora cyane ya lithium-ion yumuriro wa batiri, irashobora gukora amasaha arenga 10 nyuma yo kwishyurwa byuzuye.
●Ingano ntoya, uburemere bworoshye, byoroshye gutwara, irashobora gukoreshwa mugupima aho, irashobora kandi gukoreshwa nkibikoresho bisanzwe byo gupima laboratoire.
Iyinjiza | |
Ikigereranyo cyo gupima ingufu | 0-200V-800V, imodokakuroga |
Ikigereranyo cyo gupima | CT: 5A / 25A (bisanzwe) 100A / 500A (bidashoboka) 400A / 2000A (bidashoboka) |
Icyiciro cyo gupima icyiciro | 0 ~ 359.99 ° |
Ikigereranyo cyo gupima inshuro | 45 ~65Hz |
Umuyoboro w'amashanyarazi | Umuyoboro 3 (UA, UB, UC) |
Umuyoboro ugezweho | Umuyoboro 3 (IA, IB, IC) |
Igihe ntarengwa cyo gusesengura | Inshuro 63 |
Igihe ntarengwa cyo kubika igihe cyiminota 1 | Amezi 18 |
Ukuri | |
Igice cyo gupima amashanyarazi | |
Umuvuduko | ± 0.2% |
Inshuro | ± 0.01Hz |
Ibiriho, imbaraga | ± 0.5% |
Icyiciro | ± 0.2 ° |
Igice cyiza cyingufu | |
Ikosa ryibanze ryihanganira voltage | .5 0.5% FS. |
Ikosa ryibanze ryo kwihanganira | ≤1% FS |
Ikosa ryo gupima itandukaniro ryicyiciro hagati ya voltage yibanze nubu: | ≤0.2 ° |
Harmonic voltage yibirimo gupima ikosa | ≤0.1% |
Harmonic ikigezweho cyo gupima ikosa | ≤0.2% |
Ibyiciro bitatu bya voltage iringaniza: | ≤0.2% |
Ikosa ryo gutandukana na voltage | ≤0.2% |
Ikosa ryo guhinduranya amashanyarazi | ≤0.2% |
Ubushyuhe bwo gukora | -10 ℃ ~ +40 ℃ |
Amashanyarazi | AC 220V, 45Hz-55Hz |
kwakira amashanyarazi | ≤3VA |
igihe ntarengwa cyo gukora cya bateri | Amasaha 10 |
Kwikingira | . . |
Igipimo | 320mm *240mm *130mm |
Ibiro | 2.0kg |