GDPQ-300E Isesengura ryiza ryimbaraga
GDPQ-300E Isesengura ry'ubuziranenge bw'amashanyarazi ni igikoresho kigendanwa cyo kugerageza no gusesengura imikorere ya sisitemu y'amashanyarazi.Ikurikirana kandi ikusanya amakuru mugihe kirekire cyo gukora, inatanga isesengura rihuza hamwe nisesengura ryiza ryimbaraga.Hagati aho, ifite ibikoresho byo gusesengura amakuru, hamwe namakuru yo gupima ashobora koherezwa kuri PC.
●ARM na DSP, ububiko bwa 16M byte.
●Gukoraho ecran, byoroshye kandi byoroshye.
●Gupima amakuru no kuzigama, birashobora koherezwa kuri PC.
●Imiterere yuburyo, igishushanyo mbonera nigikorwa cyizewe.
●Kuzamura software byoroshye kandi byoroshye.
●Isesengura rirambuye ryibipimo byapimwe na software yisesengura ryamakuru muri PC.
Imikorere yo gupima metero
No | Ibintu | Ibisobanuro |
1 | Umuvuduko / Ibiriho / Inshuro | Irashobora gupima bitatu-icyiciro cya voltage, zero umurongo wa voltage, ibyiciro bitatu, umurongo wa zeru, inshuro. Irashobora kwerekana RMS, agaciro keza, igipimo cyumubyimba / impinga, imiterere yumurongo, imbonerahamwe yerekana nibindi. |
2 | Higipimo cya armonicment | Irashobora gupima shingiro ryibanze rya voltage nubu naInshuro 2 ~ 50 guhuzaumuraba.Ibisubizo byo gupima birimo guhuza neza, ibirimo guhuza, ibirimo guhuza, hamwe no kugoreka ibintu byose (THD).Ibihe byerekana amateka imbonerahamwe, n'ibindi. |
3 | Ibipimo bifatika | Irashobora gupima 0.1 ~ 19.9 ibihe interharmonics ya voltage nubu.Ibisubizo byo gupima birimo ibice bigize interharmonic hamwe nagaciro keza ka subet, igipimo cyimiterere n'ibindi. irashobora kwerekana histogrammes, imbonerahamwe yerekana, nibindi. |
4 | Igipimo cy'imbaraga | Irashobora gupima bitatu-icyiciro bine-insinga / ibyiciro bitatu-bitatu imbaraga zigaragara (ingufu z'amashanyarazi), imbaraga zikora (ingufu z'amashanyarazi)imbaraga zidasanzwe (ingufu z'amashanyarazi), imbaraga n'ibindi, irashobora kwerekanaimbonerahamwe yerekana; irashobora gupima icyifuzo of Iminota 1, 5, 10, 15, 30 60. |
5 | Ibipimo bitatu byo kutaringaniza | Irashoboragupima ibyiciro bitatu-bine / ibyiciro bitatu-by-amashanyarazi atatu ya sisitemu yumuriro wamashanyarazi hamwe nibintu byiza bikurikirana, ibice bikurikirana, ibice bitondekanya zeru, ibipimo bibi bitaringanijwe, impamyabumenyi ya zeru;Icyiciro cya fonction ya feri ya voltage eshatu nubu,vicyerekezo, icyerekezo imbonerahamwe. |
6 | Flicker | Umunota 1 uhindagurika, iminota 10 ihindagurika, gupima amasaha 2 uburebure |
7 | Umuvuduko ukabije / Kwibiza / Guhagarika | Kumenya naibiti voltage irabyimba, sags no guhagarika ibyabaye. |
8 | Sshishikara | Kumenya n'ibiti surge ibyabaye |
9 | Imbaraga zihuza | Irashobora kumenya 2 ~ 30 ibihe imbaraga zihuza, zishobora kwerekana histogramu, icyerekezoimbonerahamwe, n'ibindi. |
10 | Umuhengeri | Cigipimo cyo guhindura imbaraga byihuse (gukora, reaction, imbaraga zigaragara) ukurikije igihe cyagenwe (iminota 1 ~ 5) |
11 | Abimura | Cgutahura voltage irenze microseconds 20 |
8 | Gukurikirana inyandiko | Irashobora kwandika imbaraga-zihamye zubuziranenge bwibihe byigihe kirekire, harimo voltage / ikigezweho / inshuro, guhuza, imbaraga, kutaringaniza ibyiciro bitatu, guhindagurika / flicker, kandi intera yo gufata amajwi irashobora guhinduka kuva kumasegonda 3 kugeza kuminota 30. |
9 | Oscilloscope | Reba voltage / imiterere yikimenyetso cyerekana |
Buri cyerekezo cyukuri kubikorwa byo gutahura
Ingingo | Urwego | Gupima ukuri | Ongera wibuke |
Voltage / ikigezweho / inshuro | Three icyiciro cya voltage: 1000V (agaciro keza) Zero umurongo wa voltage: 70V (agaciro keza) Ticyiciro cya hree kigezweho: 6000A (agaciro keza, 1000A sensor ya none kubushake) Zumurongo wa ero ugezweho: 25A (agaciro keza) Fibisabwa: 40-70Hz | Umuvuduko:0.1% rdg±0,05% fs Ibiriho: 0.2% rdg±0,05% fs Fibisabwa: gusoma±0.01Hz | Here, dukoresha Icyiciro cya voltage yumurongo nkibipimo byinshyi |
Igipimo cya Harmonic | Voltage ihuza: THD +Umuhengeri shingiro+ 2-50 inshuro zihuza umurongo. Cguhuza byihutirwa: THD +Umuhengeri shingiro+ 2-50 inshuro zihuza umurongo. | Umuvuduko uhuza umuyaga: Uh≥1% UN, ±5% Uh; Uh<1% UN, ±0.05% UN Umuhengeri uhuza: Ih≥3% IN, ±5% Ih; Ih<3% IN, ±0.15% IN | |
Inter guhuzaumurabaigipimo | Voltage ihuza: inshuro 0.1 ~ 19.9Guhuzaumuraba. Cguhuza byihutirwa: inshuro 0.1 ~ 19.9Guhuzaumuraba | UmuvudukoGuhuzaumuraba: Uih≥1% UN,5% Uih; Uih<1% UN,0.05% UN; IbirihoGuhuzaumuraba: Iih≥3% IN,5% Iih; Iih<3% IN,0.15% IN | |
Power / Ingufu z'amashanyarazi | Aimbaraga za ctive: 700kVA Rimbaraga zidasanzwe: 700kVAR Impamvu zingufu: 0.00 ~ 1.00 Aingufu za ctive: 10000kWh Aingufu za kibyeyi imbaraga: 10000kVAh Ringufu zingirakamaro: 10000kVARh Average power factor: 0.00-1.00 | Active: gusoma±0.5% Aumubyeyi: gusoma±0.5% Igikorwa: gusoma±0.5% Power factor: gusoma±0.005 | |
Three icyiciro cyo kutaringaniza | Fimbaraga zidasanzwe: 1000V (agaciro keza) Fikigezweho kidasanzwe: 6000A (agaciro keza) Finshuro zidasanzwe: 40-70Hz Pinguni ya hase: 0-360degree Uuburinganire: 0.0% -100% | Voltage: 0.1% rdg±0,05% fs Cbyihutirwa: 0.2% rdg±0,05% fs Fibisabwa: gusoma±0.01Hz Pinguni: gusoma±0.3 Voltage kutaringaniza: gusoma±0.2% Ckuringaniza byihutirwa: gusoma±0.2% | Hano, dukoresha icyiciro cya voltage yumurongo nkumubare wuzuye wo gupima |
Umuvuduko w'amashanyarazi | Iminota 1 ihindagurika, igihe gito gihindagurika, igihe kirekire | Iminota 1 ihindagurika:±5.5% Iminota 10 mugufi:±5% Amasaha 2 maremare:≤ ± 5% | |
Umuvuduko urabyimba, kwibiza no guhagarika | Kurikirana kandi wandike icyiciro kimwe / ibyiciro byinshi bya voltage kubyimba, voltage dip hamwe nimbaraga zigihe gito | Igice cya kabiri-RMS, gutangira igihe, igihe bimara, ikosa ryanyuma ± 10ms | Kugera kuri 40 ibyabaye |
Kubaga Ibiriho | Kurikirana no kwandika icyiciro kimwe / ibyiciro byinshi byihuta | Igice cya kabiri-rms agaciro, gutangira igihe, igihe, igihe cyanyuma ikosa ± 10ms | Hagarika gupima mugihe ufata ibyabaye |
Imbaraga zo guhuza imbaraga | Ibihe byose byimbaraga zihuza: 1 ~ 30 Guhuza imbaraga zose zikora:∑P Guhuza imbaraga zose zifatika:∑Q Imbaraga zihuza imbaraga zose zikora: +∑P Imbaraga mbi ihuza imbaraga zose zikora: -∑P Imbaraga zihuza imbaraga zose zifatika: +∑Q Imbaraga zitari nziza zihuza imbaraga: -∑Q | Gusoma imbaraga zihuza: ± 0.5% | |
Umuhengeri | Irashobora gutahura iminota 1, 3, 5 yuburebure bukora, butagaragara, ikigaragara cyigice cya kabiri cyumuriro, cyerekana imbaraga zimpinduka | Igice cya kabiri cyimbaraga zo gusoma: ± 0.5% | |
Inzibacyuho | Umuyoboro wa voltage ushingiye ku gaciro karenze 120% | 1.t.we igihe ntarengwa cyibintu byapimwe birenze microseconds 2.amahirwe yo gufata ibyabaye 98.7% | Ibyabaye 20 birashobora kubikwa mubipimo bimwe |
Minyandiko | Record ibipimo birimo voltage, ikigezweho, inshuro, voltage / umuyaga uhuza (byose bihuza + inshuro 1-25 bihuza), tkuringaniza icyiciro;ibikorwa / bifatika / imbaraga zigaragara, imbaraga zingufu;guhindagurika / guhindagurika | Intera yo kubika amakuru: 3s ~ 30min Intera ni 3s, naho igihe cyo gukurikirana ni 16h; Intera ni 30min, naho igihe cyo gukurikirana ni 960h. | |
Digital oscilloscope | Three icyiciro cya voltage, ibyiciro bitatu byumuvuduko, zeru yumurongo wa zeru na zeru zumurongo wihuta | Icyiza.inshuro nyinshi: 200kHz Min.inshuro nyinshi: 100Hz |
●Umuvuduko w'amashanyarazi winjiza loop:
Kwinjira bitaziguye, kwinjiza inzitizi: 1MΩ, 20pF
Ibipimo bipima: imbaraga zingirakamaro 1000V
Gukoresha ingufu: munsi ya 0.5VA / icyiciro
●Ibiriho byinjira:
Kubona mu buryo butaziguye
Urwego rwo gupima: Agaciro keza 1A, 5A, 10A, 100A, 500A, 1000A, 3000A (hitamo sensor igezweho)
Gukoresha ingufu: munsi ya 0.5VA / icyiciro
●Gupima ibimenyetso byerekana inshuro: 40Hz-70Hz
●Erekana ecran: 5.7 inch 640 * 480 ibara LCD hamwe na ecran ya ecran
●Ububiko bwo kwibuka: 128M byte FLASH
●Hanze y'icyambu cyo kubikamo: USB (ucomeka muri USB disiki)
●Amashanyarazi akora: Li-bateri yishyurwa, 5-6 amasaha yo gukora kugirango yishyure byuzuye
●Amashanyarazi: AC100-240V / DC 16.8V-1A adaptateur / charger
Ikizamini | 1 set |
5A clamp y'ubu | Ibice 3 |
Umuyoboro wikizamini cya voltage | Igice 1 |
Amashanyarazi | Igice 1 |
Hindura insinga | Igice 1 |
QC pass | Kopi 1 |
Igitabo cyumukoresha | Kopi 1 |
Raporo y'ibizamini by'uruganda | Kopi 1 |
Urutonde | Kopi 1 |