Ikizamini cya GDRB-F Ihinduranya Ikizamini (SFRA & Impedance Method)
●Kubona no kugenzura ukoresheje umuvuduko mwinshi, microprocessor ihuriweho cyane.
●Itumanaho USB interineti ikoreshwa hagati ya mudasobwa igendanwa.
●Ibyuma byifashisha tekinoroji yihariye ya DDS yihuta yo gusikana (USA), irashobora gusuzuma neza amakosa nkumuyaga ugoretse, uhindagurika, uhinduranya, uhindagurika, uhinduranya imirongo migufi ya disikuru hamwe no guhuza ibice bigufi.
●Umuvuduko mwinshi-umuyoboro-16-bit A / D icyitegererezo (mukigeragezo cyumurima, kwimura igikanda, hamwe numurongo wikurikiranya werekana impinduka zigaragara).
●Ibimenyetso byerekana amplitude byahinduwe na software, kandi agaciro ka amplitude ni ± 10V.
●Mudasobwa izahita isesengura ibisubizo byikizamini kandi itange inyandiko za elegitoronike (Ijambo).
●Igikoresho gifite ibipimo bibiri byo gupima: gupima umurongo wumurongo wo gusikana no gupima igice cyo gupima igice, guhuza nuburyo bwo gupima amatsinda abiri ya tekinike mubushinwa.
●Ibiranga amplitude-frequency birahuye nibisobanuro bya tekiniki yigihugu kubijyanye na test ya amplitude-frequency ibiranga.X.Umukoresha arashobora guhitamo ukurikije ibikenewe.
●Sisitemu yo gusesengura amakuru yikora.
Kugereranya gutambitse kugereranya guhuza ibice bitatu A, B na C.
Ibisubizo ni ibi bikurikira:
Consist Guhoraho bihebuje
Consist Guhora neza
Guhuzagurika nabi
④ Guhora mubi
Kugereranya birebire AA, BB, CC yita amakuru yumwimerere hamwe namakuru agezweho mugice kimwe cyo kugereranya ihindagurika
Ibisubizo by'isesengura ni:
Ing Kuzunguruka bisanzwe
Formation Guhindura byoroheje
De Guhindura ibintu mu buryo bushyize mu gaciro
De Guhindura cyane
●Ijambo inyandiko ya elegitoronike irashobora guhita ikorwa kugirango ubike no gucapa.
●Igikoresho kirashobora kuzuza byuzuye ibisabwa bya tekiniki yumuriro w'amashanyarazi DL / T911-2004 "Isesengura ryibisubizo byerekeranye no guhindura imikorere ya transformateur".
●Igerageza rya transformateur ihinduranya igizwe nigice cyo gupima hamwe na software isesengura.Igice cyo gupima kiyobowe na yihuta yihuta ya microcomputer, kandi igizwe no gutanga ibimenyetso no gupima ibimenyetso.Igice cyo gupima gikoresha USB interineti kugirango ihuze na tablet cyangwa mudasobwa igendanwa.
●Mubikorwa byikizamini, gusa bisi ihuza bisi ya transformateur igomba gukurwaho, kandi ibizamini byose birashobora kurangira utamanitse igifuniko no gusenya transformateur.
●Igikoresho gifite imirongo itandukanye yumurongo wumurongo wo gupima ibikorwa byo gupima sisitemu yo gupima, umurongo wumurongo wohanagura wo gupima ibipimo bya scan bigera kuri 10MHz, intera ya scan intera irashobora kugabanywamo 0.25kHz, 0.5kHz na 1kHz, kugirango itange isesengura ryinshi rya transformateur Guhindura.
●Igikoresho gifite ubwenge bwinshi, cyoroshye gukoresha, kandi gifite imirimo myinshi nko guhinduranya urwego rwikora no guhinduranya byikora byikora.
●Porogaramu ikoresha Windows platform, ihuza na sisitemu ya Windows98 / 2000 / winXP / Windows7.Tanga abakoresha nuburyo bworoshye kandi bworoshye-gukoresha-kwerekana kwerekana.
●Tanga isesengura ryamateka yo kugereranya, irashobora kwikorera amateka menshi yo gutondekanya icyarimwe icyarimwe, irashobora guhitamo byumwihariko umurongo uwo ariwo wose wo gusesengura utambitse kandi uhagaritse.Bifite ibikoresho byinzobere mu gusesengura no gusuzuma sisitemu, irashobora guhita isuzuma imiterere yimiterere ya transformateur, igatwara imirongo 6 icyarimwe, hanyuma igahita ibara ibipimo bijyanye na buri murongo, igahita isuzuma ihinduka ryimiterere, hanyuma igatanga a umwanzuro wo gusuzuma.
●Imikorere ikomeye yo gucunga porogaramu, urebye neza ibikenewe gukoreshwa kurubuga, kandi ihita ikiza ibipimo byibidukikije kugirango itange urufatiro rwo gusuzuma imiterere ya transformateur.Ibipimo byo gupima bihita bibikwa kandi bifite imikorere yo gucapa ibara, byorohereza abakoresha gutanga raporo y'ibizamini.
●Porogaramu ifite ibiranga abakoresha neza.Ibyinshi mubipimo byo gupima nibintu bidahitamo.Ibisobanuro birambuye bya transformateur birashobora kubikwa kugirango bisuzumwe, kandi nta mpamvu yo kwinjira kurubuga, kandi uyikoresha arashobora kongeraho no guhindura amakuru nyuma, byoroshye gukoresha.
●Porogaramu ifite ubwenge buhanitse.Nyuma yo kwinjiza no gusohora ibimenyetso byahujwe hamwe nibipimo byimiterere byashyizweho, imirimo yose yo gupima irashobora kurangira, kandi amateka yumurongo wamateka arashobora gufungurwa mugupima igihe icyo aricyo cyose cyo kugereranya no guhagarika gupima.
●Igihe gikenewe kuri buri cyiciro cyo gupima kiri munsi yamasegonda 60.Igihe cyose cyo gupima ihindagurika ryimiterere ya transformateur yingufu zifite imbaraga zo hejuru, ziciriritse kandi ntoya (ubushobozi na voltage urwego ntabwo bigarukira) ni munsi yiminota 10.
●Iyo upimye transformateur, abakozi bakoresheje insinga barashobora guhitamo uko bishakiye ibimenyetso byinjira nibisohoka, bidafite ingaruka kubisubizo byo gupima.Abakozi bakoresha insinga barashobora kuguma kuri tank ya transformateur batiriwe bamanuka, bikagabanya imbaraga zumurimo.
Uburyo bwa Scan:
1. Gukwirakwiza umurongo wo gusikana
Ikigereranyo cyo gupima: (10Hz) - (10MHz) 40000 yo gusikana, gukemura 0.25kHz, 0.5kHz na 1kHz.
2. Gukwirakwiza ibice byo gukwirakwiza inshuro
Ibipimo byo gupima inshuro nyinshi: (0.5kHz) - (1MHz), amanota 2000 yo gusikana;
(0.5kHz) - (10kHz)
(10kHz) - (100kHz)
(100kHz) - (500kHz)
(500kHz) - (1000kHz)
Ibindi bikoresho bya tekiniki:
1. Ikigereranyo cyo gupima Amplitude: (-120dB) kugeza (+20 dB);
2. Ibipimo bya Amplitude byukuri: 1dB;
3. Gukuraho inshuro nyinshi: 0.005%;
4. Ibimenyetso byinjira byinjira: 1MΩ;
5. Ibimenyetso byo gusohora inzitizi: 50Ω;
6. Ibimenyetso byerekana amplitude: ± 20V;
7. Mu cyiciro cyo gusubiramo ikizamini cyo gusubiramo: 99.9%;
8. Ibipimo bipima ibipimo (LxWxH): 340X240X210 (mm);
9. Igikoresho cya aluminiyumu yububiko (LxWxH): 370X280X260 (mm);Agasanduku k'insinga aluminiyumu yisanduku (LxWxH) 420X300X300 (mm);
10. Uburemere muri rusange: 10kg;
11. Ubushyuhe bwo gukora: -10 ℃ ~ + 40 ℃;
12. Ubushyuhe bwo kubika: -20 ℃ ~ + 70 ℃;
13. Ubushuhe bugereranije: <90%, Kudahuza;