GDSF-311WPD 3-Muri-1 SF6 Isesengura rya gaz
GDSF-311WPD (GDSF-411WPD) nigikoresho cyiza mugihe bibaye ngombwa kugerageza ibirimo amazi, ubuziranenge nibicuruzwa bya gaze ya SF6.Ibice byingenzi bigize ikizamini cyikime ni sensor ya DRYCAP® yakozwe na societe ya Finlande Vaisala.Ihame rya infrarafarike ya SF6 isuzuma ibyuma byogukora isuku yakozwe na societe yuburayi Sensor ikoreshwa mugupima ubuziranenge bwa gaze ya SF6.Imashini ikora amashanyarazi yakozwe na Sosiyete ya Mombabo mu Busuwisi ikoreshwa nkibintu byifashishwa mu gupima ibicuruzwa byangirika bya SF6.Hamwe nibikoresho byumwuga hamwe na algorithms nziza ya software ya STMicroelectronics, twabyaye igisekuru gishya cya 3-muri-1 isesengura gaze.
SF6Ubushuhe
●Uburyo bwo gupima: Ihame ryo gupima rirwanya kandi rifite ubushobozi
●Urwego rwo gupima: ikime -80 ℃ - + 20 ℃ (inkunga ppmv)
●Ukuri: ± 1 ℃
(iyo ubushyuhe bwikime buri munsi ya 0 ℃, ibyasohotse bya sensor nubukonje)
●Igihe cyo gusubiza: 63% [90%]
+ 20 → -20 ℃ Td 5s [45s]
-20 → -60 ℃ Td 10s [240s]
●Icyemezo: 0.01 ℃
●Gusubiramo: ± 0.5 ℃
●Igice cyo kwerekana: ℃, ppm, ℃ P20 (agaciro kahinduwe kuri 20 ℃)
●Gazi itemba: 400-600ml / min
●Kugaragaza neza: 0-1000mL metero yimibare
●Icyitegererezo cya gaze: ≤1MPa
SF6Isuku
●Uburyo bwo gupima: Ihame ryo gupima Infrared (sensor ya NDIR)
●Urwego rwo gupima: 0 ~ 100% SF6
●Igihe cyo gusubiza: [90%] 60s
●Ukuri: ± 0.5% FS
●Gusubiramo: ± 0.5%
●Icyemezo: 0.01%
●Igice cyerekana:%
SF6Ibicuruzwa byangirika
●Uburyo bwo gupima: Ihame ry'ibipimo by'amashanyarazi (ibyuma bikoresha amashanyarazi)
●Urwego rwo gupima: H2S: 0 ~ 200ppmv
SO2: 0 ~ 200ppmv
CO: 0 ~ 500ppmv
HF: 0 ~ 50ppmv
●Ukuri: H2S: 10ppmv ± 3%
SO2: 10ppmv ± 3%
CO: 50ppmv ± 4%
HF: 10ppmv ± 3%
●Gusubiramo: H2S: 10ppmv ± 2%
SO2: 10ppmv ± 2%
CO: 50ppmv ± 2%
HF: 10ppmv ± 2%
●Icyemezo: 0.01ppmv
●Igice cyo kwerekana: ppmv
●Amashanyarazi: 220VAC ± 10%, 50Hz, AC / DC gukoresha, kurinda amafaranga arenze, gukora ubudahwema ntabwo biri munsi ya 8hours.
●Koresha ubushyuhe bwibidukikije: -20 - + 60 ℃
●Ubushuhe bwibidukikije: 90% RH
●Ingano yo gupima agaciro: Nta ngaruka zumuvuduko no gutemba
●Igipimo: 395 * 295 * 155mm
●Uburemere: hafi 2kg.
GDSF-411WPD SF6Ibicuruzwa byangirika
●Ukuri: H2S: <10ppmv ± 0.3ppmv;> 10ppmv ± 3%
SO2: <10ppmv ± 0.3PPmv;> 10ppmv ± 3%
●Gusubiramo: H2S: <10ppmv ± 0.2ppmv;> 10ppmv ± 2%
SO2: <10ppmv ± 0.2PPmv;> 10ppmv ± 2%
●Igikorwa cyo gutunganya no kuzuza: gutunganya icyumba 2L,igihe cyo gutunganya ≤ 5min
Hamwe nimikorere yo kumisha gaze
●Igipimo: 395 * 295 * 315mm
●Uburemere: hafi 5kg.
Ikizamini gikuru | Igice 1 |
Adapt | 1 gushiraho |
Umuyoboro wa Teflon (ushizemo valve ihindura flux na connexion yihuta) | 1 gushiraho |
Umuyoboro murizo | 1 gushiraho |
Ibice by'ibicuruzwa | 1 gushiraho |
Amashanyarazi | Igice 1 |
Umukoresha's Ubuyobozi | Igice 1 |
Raporo y'Ikizamini | Igice 1 |