GDWG-V SF6 Ikwirakwiza Gazi (Ubwoko bwa IR, Kwerekana kabiri)
GDWG-V SF6 Detector ya gazi ni infragre yimyenda itukura (tekinoroji ya NDIR) hamwe no kwerekana kabiri.Nibara INCELL TFT yerekana kandi igihe-nyacyo cyerekana kwibanda kuri SF6.Ihita imenya vuba SF6 yamenetse, GIS yamenetse nigipimo cyumwaka gisohoka muburyo bwiza no mubwinshi.Nigikoresho cyiza kibereye ishami rishinzwe gutanga amashanyarazi, gushiraho no kuvugurura ishami, ikigo cyipima amashanyarazi.
●Ibikoresho Byinshi byo Guhindura Ibikoresho
●Rotor vane ya kajugujugu
●Sisitemu yo kohereza gaze
●Kumenya kuzimya umuriro
●Ubushakashatsi bukora neza bwububiko
●Kumenya akaga
●Nta mirasire.
●Ntibikenewe gusimbuza umuvuduko mwinshi gazi ya argon buri gihe.
●Nta mpamvu yo kwegera gaze yumuvuduko mwinshi.
●Ntibikenewe gusimbuza sensor buri gihe, birahendutse.
●Imikorere ihamye, igiciro gito cyo kubungabunga.Ntabwo ari ngombwa gukora kalibrasi yumurongo buri mwaka.
●Nta ngaruka ziterwa nubushuhe nibidukikije.
●Ubukangurambaga bukabije, kugeza 0.01ppmv.
●Iyo kumeneka gukomeye cyangwa gazi ya SF6 igera kuri 100%, ntabwo izaba yanduye cyangwa yangiritse.
●Ibara TFT Muri-Akagari ka ecran, kwerekana kabiri, kugaragara mumirasire y'izuba.
●Bateri yubatswe muri Litiyumu.
●Umukoresha-asobanura impuruza hamwe nijwi numucyo.
●Kwiyunvikana cyane no gutuza neza.
●Umuvuduko wo gupima byihuse, igihe kigera kuri 3s.
●Ubushyuhe n'ubushyuhe.
●Gusa igisubizo kuri gaze ya SF6, ntabwo ari iyindi gaze.
●Ibipimo byo gupima gazi byerekana ko nta burozi bwa sensor buzabaho ahantu hose.
●Icyuma gihoraho ubushyuhe burashobora kwemeza ko sensor idafite ubushyuhe bwubushyuhe ubwo aribwo bwose.
●Ingano ntoya, yoroshye gutwara, ibereye kurubuga rukora.
●Hamwe na gasakoshi itanyerera, byoroshye gutwara.
●Kubika amakuru kugeza kumatsinda 100.
●Aluminium-yumucyo mwinshi hamwe nigikonoshwa cyuzuye.
●Ipaki yo hanze ikoresha plastike yubuhanga, hamwe n’amazi, itagira umukungugu.
●Ihame ryo gupima: Sensor idakwirakwiza sensor (NDIR)
●Urwego rwo gupima: 0-2000ppmv SF6 cyangwa 0-50ppmv
●Icyemezo: 0.1ppmv cyangwa 0.01ppmv
●Ukuri: ± 2% FS (0-1000ppm)
●Ikosa risubirwamo: ≤ ± 1%
●Ibyiyumvo: 0.1ppmv
●Igihe cyo gusubiza: ≤2s
●Igihe cyo gukira: ≤5s
●Guhagarara: ≤ ± 20ppm, amasaha arenga 1000
●Guhindura zeru: ≤ ± 1% (FS / umwaka)
●Ikosa ry'umurongo: ≤ ± 1%
●Ubushyuhe bwo kubika: -20 ~ + 60 ℃
●Ubushyuhe bwo gukora: -20 ~ + 50 ℃
●Uburyo bw'icyitegererezo: Yubatswe muri pompe ya electromagnetic diaphragm, ubwoko bwikora bwikora, butemba bugera kuri 1L / min.
●Umuvuduko wakazi: 220VAC ± 10%, 50Hz Cyangwa Yubatswe muri Li-bateri, amasaha 8 akora.
●Igipimo: 160 × 220 × 70mm, imbunda y'intoki 106mm * 170mm * 120mm.
●Uburemere: igice nyamukuru hafi 1.5 kg, imbunda y'intoki hafi 0.5kg