GDYB-S3 Ibice bitatu byingufu za Metero Ikizamini (imyanya 3)
Sisitemu neza: 0.1%;
Ibice bitatu by'isoko:
a.Umuvuduko w'amashanyarazi asohoka:
3 * 57.7VY 3 * 100V ∆;
3 * 220V Y 3 * 380V ∆;
Urutonde rushobora guhinduka 0 ~ 120% bikomeza guhinduka
Guhindura neza: kurenza 0.01%
b.Ibisohoka hanze: 25mA, 0.1A, 1A, 5A, 25A, 100A;
Urutonde rushobora guhinduka 0 ~ 120% bikomeza guhinduka
Guhindura neza: kurenza 0.01%
Ibisohoka byibuze: 1mA (ubunyangamugayo: <5%)
c.Imbaraga zisohoka: (voltage circuit) 3 * 50VA
(umuzunguruko w'ubu) 3 * 150VA
d.Ibisohoka biva hanze, bigezweho, imbaraga zihamye: ≤0.02% / 120S
e.Urwego rwo kugoreka ibintu bisohoka voltage hamwe nuburyo bugezweho: ≤0.5%
f.Ikigereranyo cy'imfuruka eshatu: hagati ya 120 ° ± 0.3 °
g.Urutonde rwinshuro: 45Hz ~ 65Hz, intambwe: 0.01Hz
h.Icyiciro cy'icyiciro: -180 ° ~ 180 °, intambwe: 0.01 °
i.Kwerekana ibipimo byukuri: Voltmeter, ammeter: ± 0.01%
Metero yicyiciro: ± 0.01 °
Imetero yumurongo: ± 0.01Hz
Ibisohoka byibuze bigezweho: 1mA;Ukuri: ≤5%;
Ubushobozi bwo gutwara ibintu (metero 20)
Umuvuduko w'amashanyarazi: 800VA;
Ibisohoka ubu: 2500VA;
Umuvuduko & Guhindura
Urutonde rushobora guhinduka: (0% ~ 120%) x igipimo cyo gupima;
Guhindura neza: 10%, 1%, 0.1%, 0.01%;
Guhindura icyiciro:
Urwego rushobora guhinduka: 0 ° ~ 360 °;
Ubwiza bushobora guhinduka: 10 °, 1 °, 0.1 °, 0.01 °;
Guhindura inshuro:
Urutonde rushobora guhinduka: 45Hz ~ 65Hz;
Guhindura neza: 1Hz, 0.1Hz, 0.01Hz;
Imbaraga zisohoka zihamye: ≤0.05% / 120S;
Ibisohoka voltage & kugoreka ibintu:
Umuvuduko: ≤0.5%;
Ibiriho: ≤0.5%;
Igenamiterere rihuza:
Umubare uhuza: inshuro 2 ~ 21;
Ibirimo bihuye: inshuro 2 ~ 21 inshuro ≤40% (ugereranije numuhengeri wibanze);
voltage inshuro 2 ~ 21 ≤40% (ugereranije numuhengeri wibanze);
Icyiciro gihuza: 0 ° ~ 359.99 °;
Igikoresho cyo gukurikirana:
Imetero isanzwe yerekana neza: Umuvuduko: 0.01%;
Ibiriho: 0.01%;
Imbaraga: 0.01%;
Icyiciro: 0.01;
Inshuro: 0.01;
Ironderero 1: 1 ibipimo bya transformateur:
Ukuri: 0.01%;
Imbaraga zisohoka: 60VA;
Ikigereranyo cyo gupima ubu: 1mA ~ 120A (1: 1);
Icyerekezo nyamukuru
a) Ukuri: 0.01% (COS∮ = 0.5C… 1… 0.5L);
b) Ikigereranyo cyagenwe: 50Hz / 60Hz ± 5%;
c) Ibanze ryibanze: 3 × 0.001-120A;
d) Icyiciro cya kabiri: 3 × 0.001-120A;
e) Ibisohoka bisohoka (buri cyiciro):
0.5W (ibisohoka: 0.001-1A);
0.7V igabanijwe nagaciro keza (ibisohoka: 1-120A);
f) Ibisohoka bitwara voltage: Byinshi.0.5V (ibisohoka muri iki gihe Max. 120A);
Ibipimo byahinduwe muri iki gihe: 265 x 200 x 240 mm (L x W x H);
Uburemere: 12kg;
Igipimo:
Inkomoko yo kugenzura: 610 x 800 x 1920mm (L x W x H);
Ikigereranyo cya metero: 2350 x 750 x 1850mm (L x W x H);