GDYZ-301A Ikizamini cya Zinc Oxide Kubagwa
Nibikoresho byihariye byo gupima zinc oxyde ikora amashanyarazi.Igikoresho kirashobora gupima neza kandi gihamye gupima abata muri yombi hamwe na monitor ya compte y'ibikorwa mugihe ibikoresho biri gukora.Irashobora kandi kugenzura monitor ya ammeter.
●8inch ibara LCD ikoraho ecran, umuvuduko mwinshi printer ya printer.
●Ibipimo byo gupima insinga na simeless nimwe.
●Wireless sampling, hamwe nintera ndende.
A. Wired: gukoresha mu nzu, cyangwa kurubuga aho PT sampling wiring kabine iri hafi hamwe nuwagerageje gufata inkuba.
B. Wireless: gukoresha hanze, cyangwa kurubuga aho PT sampling wiring kabinet iri kure yuwagerageje gufata inkuba, intera idafite umugozi igera kuri 1000M.
●Ibyiciro bitatu birashobora gupimirwa icyarimwe.Imiyoboro irwanya imiyoboro 3 irashobora gupimirwa icyarimwe, hagati aho, hariho uburyo bubiri bwo kurwanya interineti: 1) nta kwivanga: inguni y'intera ntishobora kubarwa no gukosorwa mu buryo bwikora muri ubu buryo;2) Hamwe no kwivanga: inguni yo guhuza intera irashobora kubarwa no gukosorwa.Igihe kimwe gusa guhuza kurangiza gupima icyiciro cya ABC.
●Yubatswe mubushobozi buhanitse Li-bateri, ibereye ntamashanyarazi.
Uimiterere | -20 ℃ - 50 ℃ | RH<80% |
Cgukoresha amashanyarazi | AC 220V ± 10% | |
Iyinjiza rya PT yerekana voltage | 0-300V | |
Input irwanya umuyoboro wa voltage | ≥150kΩ (with fuse) | |
Gupima ukuri kwa PT yerekanwe na voltage | ±(2% yo gusoma + 0.5V) | |
Mkoroshya urwego rwinjiza | 0-10mA | |
Mubworoherane bwukuri bwibanze | ± (2% yo gusoma + 5μA) | |
Mubworoherane bwukuri bwibihuza | ±(5% yo gusoma + 10μA) | |
Input irwanya umuyoboro ugezweho | ≤1Ω | |
Action igihe cyo gukurikirana | 0 ~ 99times | |
8 / 20μS impulse igezweho | ≥50Ap | |
Calibration intera ya metero iriho | 0-10mA | |
Calibration yukuri ya metero iriho | ±(2% yo gusoma + 5μA) | |
Mgukemura | Voltage | 0.001V |
Current | 0.001mA | |
Angle | 0.001 ° | |
Bigihe cyo gukora | MIgice cya 8hibyacu, voltage icyitegererezo agasanduku 12hours | |
Wintera yoherejwe | Metero 1000 no hejuru (ubusa naunobstructed) | |
Dkwigana igice cyingenzi | 320 × 270 × 140mm | |
HIkurikiranabikorwa | 180 × 120 × 80mm | |
Uburemere bwigice nyamukuru | 4kg (idafite ibikoresho) |
Main | 1piece |
Sigikoresho | 1piece |
Wishami ryitumanaho ridasubirwaho | 1piece |
Mumugozi wa easurement wibyiciro 3 birwanya imbaraga | 1piece |
Sampling kabili ya voltage yicyiciro cya 3 | 1piece |
Ogusohora umugozi wa metero ya kalibrasi | 1piece |
Gumugozi uzengurutse | 1piece |
Imbaragaumugozi | 1piece |
Charger | 1piece |
FKoresha | 3pcs |
Pimpapuro | 1roll |
Clip ya Alligator | 8pc |
Raporo y'ibizamini | Igice |
Umukoresha'Ubuyobozi | Igice |