GDYZ-302 Wireless Zinc Oxide Kubaga Ikizamini
GDYZ-302 Zinc Oxide Arrester Live Tester nigikoresho kidasanzwe gikoreshwa mugupima amashanyarazi ya Zinc Oxide Arrester.Birakwiriye gutahura cyangwa kuzimya amashanyarazi ya Zinc Oxide Arrester yinzego zinyuranye za voltage, kugirango ubone inenge ziteye akaga nko kugabanuka kwimbere yimbere no gusaza kwa plaque mugihe.
Igikoresho kiroroshye gukora kandi cyoroshye gukoresha.Ibikorwa byose byo gupima bigenzurwa na mudasobwa yinganda.Irashobora gupima ibyuzuye, irwanya imbaraga hamwe nuburinganire bwayo, imbaraga za frequency reference voltage na garmonics, imbaraga zikora nibitandukaniro.Yerekana imiterere yukuri ya voltage nubu.Igikoresho gikoresha ikoranabuhanga rya digitifike yikoranabuhanga hamwe na software irwanya kwivanga nko gusesengura guhuza no kuyungurura imibare kugirango ibisubizo bipimwe bibe byiza kandi bihamye.Irashobora gusesengura neza ibikubiye mu muhengeri shingiro hamwe na gatatu kugeza ku ya karindwi ihuza, kandi irashobora gutsinda ingaruka zo kwivanga hagati.Gupima imbaraga zirwanya uruhande-fata abafata.
●800 * 480 ibara LCD ikoraho, printer yihuta yubushyuhe;ibishushanyo ninyandiko byerekana, intangiriro yimbere, byoroshye kubakozi bo murwego rwo gukora no gukoresha.
●Ikwirakwizwa rya Wireless signal ya PT irenga metero 400, ishobora kugera kuri metero 2000 kubisabwa.
●Birakwiriye kubafata nzima, power off arrester cyangwa test ya laboratoire.
●Mubyukuri mugere kubice bitatu byicyiciro hamwe nibice bitatu byapima voltage icyarimwe, kunoza imikorere;igikoresho gifite intege nke gusa imbere, voltage ntirenza 12V;ibyuma bya voltage na voltage byitaruye rwose, bifite umutekano kandi byizewe.
●Imiyoboro yamenetse ya zinc oxyde ifata nayo irashobora gupimwa idafite compteur, ikemura rwose ikibazo cyikizamini cya 6 ~ 10KV.
●Ifasha byombi guhuza insinga hamwe no guhuza simusiga ya voltage yerekana ibimenyetso byerekana ibimenyetso, kandi ikanashyigikira uburyo butari voltage yo gushakisha voltage ikoresheje kubara software.
●Hamwe nimikorere ihanitse hamwe nububasha bunini bwa lithium-ion, birakenewe cyane cyane kubikoresho bidafite ingufu.
●Igikoresho gikoresha ibyuma byinjizwamo ibyuma hamwe na sisitemu y'imikorere yashyizwemo, ishobora kwagura ibikorwa byo gukina amajwi n'amashusho n'imikorere y'imyidagaduro.
●Igikoresho kirashobora gufungura no kuzimya igihe icyo aricyo cyose, kikaba gihamye kuruta igikoresho gishingiye kuri mudasobwa yinganda, kandi ntabwo byoroshye guhanuka no gusenyuka.
●Imikorere ya software irashobora kwagurwa igihe icyo aricyo cyose, ahantu hose ukurikije ibyo umukiriya asabwa.
●Ifite USB interineti kugirango ishyigikire U-disiki yohereza hanze.Irashobora gukoreshwa na USB imbeba na clavier, kandi biroroshye gukora.
●Ikarita ya SD ifite ubushobozi bwa 4 GB irashobora kubika umubare munini wamakuru yikizamini, kandi ifite imirimo yo gucunga amakuru no kubika.
●Gushyigikira porogaramu yo gucunga PC, hamwe no gucunga amateka, gusesengura amakuru, gucapa raporo nibindi bikorwa.
●Umuvuduko wihuse wikigereranyo, tekinoroji yambere yo gutunganya ibimenyetso bya digitale, imikorere ikomeye yo kurwanya interineti, ukuri gukomeye kubisubizo byo gupima.
●Agasanduku karimo umukungugu, utarinda amazi na anti-ruswa yububiko bwa plastike ifunze isanduku ifunze, ntoya mubunini, urumuri muburemere kandi byoroshye gutwara.
Amashanyarazi | Gushyigikira amashanyarazi yo hanze (12V / 2A) na bateri y'imbere |
Urwego rwo gupima | Amashanyarazi yamenetse (agaciro keza): 0 ~ 10mA (Yagutse) Umuvuduko (agaciro keza): 30-100V (Yagutse) |
Ibipimo bifatika | Ibiriho: ± 2% gusoma ± 1 digitale yuzuye> 100 μA Umuvuduko: ± 5% gusoma +1 digitale yerekana ibimenyetso bya voltage <30V: Umuvuduko: Ikimenyetso cya voltage yerekana> 30V: Uburyo bw'insinga: + 2% gusoma +1 digital; Uburyo bwa Wireless: + 5% gusoma +1 digital; |
Ibipimo byo gupima | Umuyoboro wuzuye wuzuye, RMS yibanze nagaciro keza kumashanyarazi; Umuhengeri wibanze RMS yamenetse yibintu birwanya hamwe na RMS inshuro 3, 5 na 7; Kumeneka kurubu ibintu birwanya agaciro: impinga nziza Ir + impinga mbi Ir-; Umuyoboro wibanze wibanze, voltage yuzuye, icyiciro cyicyiciro gitandukanye; Umuvuduko RMS; Gukoresha ingufu; |
Uburyo bwo gutoranya ibimenyetso byerekana ibimenyetso bya voltage | Guhuza insinga: 40m (Yagutse) Guhuza Wireless:> 400m (Yagutse) |
Batteri | Igihe cyo kwishyuza:> amasaha 6 Gukomeza gukora:> amasaha 4 Igihe cyakazi cyigihe:> amasaha 8 |
Igipimo | Igice nyamukuru: 36cm * 26cm * 14cm Ibikoreshobimpfizi: 42cm * 33cm * 20cm |
Ibiro | Igice nyamukuru: 5.0kg, agasanduku k'ibikoresho: 9.0kg |