GDKH-12 Yayobora Amashanyarazi ya Acide
Igikoresho nigikoresho cyihariye cyo gukora bateri igenzurwa na aside-acide hamwe na voltage ya batiri ya 2V, 6V, cyangwa 12V hamwe nubushobozi bwinyuma kubera sulfide korohereza plaque ya electrode.Hamwe na "activation" na "reba gusohora", "kwishyuza byikora" nibindi bikorwa bya bateri.
Ibi bikoresho bikurikiza amahame yikoranabuhanga agezweho agezweho, kandi yakoze urukurikirane rwiterambere mubushakashatsi no gukoresha ikoranabuhanga rishya, ibikoresho bishya, ibikoresho bishya, nibikorwa bishya.Irashobora gukora igenzura ryisuzuma ryimiterere yibintu nyabyo bya bateri zinyuma zinyuma, kandi ibyiciro bitatu byikora byikora cyangwa byikurikiranya byinshi byashyizweho kugirango bishyure kandi bisohore bateri inshuro nyinshi, kugirango ibikoresho bikora binaniranye plaque yongeye gukora, kandi ubushobozi bwa bateri isubira inyuma iriyongera.Ifite kandi porogaramu ya PC yo kohereza amakuru yakusanyijwe kuri mudasobwa kugirango isesengurwe ritandukanye.
Igikoresho gifite imbaraga nyinshi, ingano nto, uburemere bworoshye, hamwe na software yuzuye yo gucunga amakuru kuri mudasobwa yakiriye.Imigaragarire ya gicuti kandi ikoresha-imashini yimikoranire yabantu igabanya cyane igeragezwa rya buri munsi no kubungabunga imirimo ya bateri kandi ni umufasha mwiza wo kubungabunga bateri.
●Igikoresho gikoresha ecran ya ecran, kandi interineti irashobora gukoreshwa muburyo butaziguye ukoresheje ikaramu yo gukoraho cyangwa urutoki.Hariho uburyo bubiri bwo kubika amakuru: ububiko bwimbere nububiko bwa SD ikarita yo hanze.
●Hamwe na voltage nyinshi, hejuru-yubushyuhe, gushyushya cyane nibindi bikorwa byo kurinda.
●Igikorwa cyo gukora: Iyo bateri iri kumurongo, bateri imwe irashobora gukora.Mbere yo gukora, shiraho umubare wibikorwa bya cycle, kwishyuza rimwe hamwe nigihe cyo gusohora, voltage yo gukingira nibindi bipimo, igikoresho kizahita gikora ibikorwa byo gukora;kandi werekane ingufu za bateri, kwishyuza / gusohora amashanyarazi, kwishyuza / gusohora, kwishyuza / gusohora igihe nandi makuru mugihe nyacyo;Nyuma yo gutangira ibikorwa byateganijwe birangiye cyangwa ibikorwa birangiye intoki, inzira yo gukora irashobora guhagarara.
●Imikorere yo gusezerera: Iyo bateri iri kumurongo, koresha umutwaro wubwenge wibihimbano kugirango ukore igenzura rihoraho.Shiraho "gusohora ibintu", "igihe cyo gusohora", "ubushobozi bwo gusohora", "guhagarika imbaraga za voltage" nibindi bipimo, hanyuma igikoresho kizahita gikora imirimo yo gusohora, kwerekana-igihe nyacyo cyo kwerekana amashanyarazi, ubushobozi bwa bateri, ingufu za batiri, igihe cyo gusohora n'andi makuru;iyo bateri igeze mubihe byateganijwe byo gusohora cyangwa guhagarika ibikorwa bishobora guhagarika ikizamini cyo gusohora.
●Igikorwa cyo kwishyuza: Iyo bateri iri kumurongo ureremba cyangwa kumurongo, bateri irashobora guhita yishyurwa.Shiraho ibipimo nka "kwishyuza amashanyarazi", "igihe cyo kwishyuza", na "guhagarika voltage", kandi igikoresho kizahita gikora umurimo wo kwishyuza.Kandi mugihe nyacyo cyo kwerekana amashanyarazi, ubushobozi bwa bateri, voltage ya bateri, igihe cyo kwishyiriraho nandi makuru, mugihe bateri igeze mubihe byateganijwe byo kwishyuza cyangwa guhagarika ibikorwa bishobora guhagarika kwishyuza.
●Imikorere yo kwihuta imbere imbere:
●Ibara ryinshi-ibara rya LCD ecran.
●Porogaramu yo gucunga amakuru ya mudasobwa yakiriye irakomeye kandi ni urugwiro.Itanga imicungire yamakuru, icapiro, isesengura, imibare yimibare, raporo yikizamini cyikora nindi mirimo.
Ubwoko bumwe bwo gupima voltage | 2V / 6V / 12V |
Ingero imwe ya selile yo gupima | 2V: 0 ~ 3V 6V / 12V: 0 ~ 16V |
Imikorere ya selile imwe ya voltage | 2V: 0.001V;6V / 12V: 0.001V |
Ibipimo bya voltage | 0.5% |
Kwishyuza / gusohora urwego rugezweho | 2V: 1A ~ 100A 6V: 1A ~ 30A 12V: 1A ~ 30A |
Kwishyuza / gusohora kugenzura neza | 1% |
Kugenzura ubushobozi bwa bateri | 2V: 20Ah ~ 1000Ah 6V: 20Ah ~ 300Ah 12V: 20Ah ~ 300Ah |
Umuvuduko w'akazi | AC 220 ± 15% |
Kwimura ubushyuhe | Gukonjesha ikirere ku gahato |
Ibidukikije | Ubushyuhe: 0 ℃ ~ 40 ℃ ubuhehere: 20% ~ 80RH |
Imiterere yo kubika | -20 ℃ ~ + 70 storage ububiko bwapakiwe |
Erekana | Mugaragaza cyane LCD ecran |
Igipimo | 401mm * 176mm * 273 mm |
Ibiro | 15kg |