Mu mpera z'Ukwakira, ishami rishinzwe kwamamaza ryatangaje ko isosiyete ikora ibijyanye n’ikoranabuhanga rikoresha amashanyarazi muri Sinayi yaguze icyiciro cy’ibikoresho byo gupima ibikoresho by’umutekano mu kigo cyacu.Ibikoresho byaguzwe iki gihe birimo: GDYD-D ikurikirana AC Hipot yipimisha, GDJS-6 ikurikirana ya Insulated Glove (inkweto) Umuvuduko wamashanyarazi, GDY ikurikirana ya Electroscope Imikorere Ikizamini, AGLX-20KN Ibikoresho byumutekano wamashanyarazi Ibikoresho byo gupima, GDJ ikurikirana izirinda voltage igeragezwa rya electrode, GDZG-300 ikurikirana DC yumubyigano mwinshi wa Tester, GDS-50 insulation umugozi wamashanyarazi, ibikoresho bya GDZ-R Shield Ikizamini cya Electrode, nibindi bikoresho byinshi.Kugeza ubu, iki cyiciro cyibikoresho cyarangije ikizamini cyuruganda kandi kizoherezwa kurubuga rwagenewe abakiriya mu ntangiriro zuku kwezi.
Kwikingira inkweto hamwe na gants ni ibikoresho bya ngombwa byo kurinda umutekano kubikorwa no kubungabunga sisitemu y'amashanyarazi.DL408 “Amabwiriza agenga umutekano w’amashanyarazi” na GB12011-2000 “Imiterere rusange ya tekiniki y’inkweto zikoresha amashanyarazi” ziteganya ibikoresho by’umutekano bikunze gukoreshwa nko gukingira inkweto no kwambara uturindantoki.Uburyo bwo gukora ikizamini.
GDJS-6 ikurikirana ya gants (inkweto) ihanganye nigikoresho cyo gupima voltage ikoreshwa mubikoresho bidasanzwe nka bote yanduye (gants), ikizamini cyinkoni yipimisha, electroscope, nibindi, bikemura neza uburyo bwambere bwibizamini bitari bisanzwe, byoroshya ikizamini inzira, kandi itezimbere Umuvuduko wo gutahura uragabanuka, ubukana bwo gutahura buragabanuka, kandi umutekano wabakozi bashinzwe gutahura uremezwa.Gukingira inkweto hamwe na gants zo kwihanganira kwihanganira ikizamini cya voltage, ukwezi ni igice cyumwaka, nta gusenyuka byemewe mugihe cyikizamini, kandi imiyoboro yameneka yinkweto ntizirenza agaciro ntarengwa.Iki gikoresho kirashobora kumenya neza imyuka yamenetse, gusaza kwizuba hamwe ninshuro zumuriro birashobora kwihanganira ibipimo bya voltage ya gants (inkweto) hamwe nudukoni twiziritse, kandi irashobora gutahura uturindantoki dutandatu twiziritse (inkweto) hamwe ninkoni nyinshi zikingiwe icyarimwe;ifite ibikoresho bya electroscope imikorere yo gutahura Intangiriro ya voltage nogukora anti-intervention imikorere ya electroscope irashobora kugeragezwa.Niba hatoranijwe ibikoresho byingirakamaro byifashishwa cyangwa ibikoresho bya electrode bifasha, birashobora gukoreshwa mugupima imbaraga za voltage zo kwikingira ibiringiti, kubika amakariso, gukingira amaboko, kubika imyenda, gukingira ingofero, gutera ingazi, kubika ibyuma, kubika intebe nibindi bikoresho.
Igipimo cyo gusaba
Ikoreshwa cyane mu mashami y’inganda zikoresha amashanyarazi, ishami rishinzwe ingufu, amashami yubushakashatsi bwa siyanse na kaminuza n'amashuri makuru, mugusuzuma umusaruro mwinshi no gupima uturindantoki twinshi, inkweto;inkoni ikingira, imigozi ikingira, electroscopes nibindi bikoresho.
Ibicuruzwa na serivisi byujuje ubuziranenge, ubumenyi bukomeye bwikigo hamwe nicyubahiro nimpamvu zingenzi zo gukurura abakiriya gufatanya natwe muriki gihe.HV HIPOT ntabwo itinyuka kwirengagiza gahunda zose, kandi irakaze cyane mugucunga ubuziranenge mugihe uhatanira umusaruro, ukemeza ko ibicuruzwa byose bigezwa kubakiriya bifite ireme ryiza!
Igihe cyo kohereza: Ugushyingo-08-2021