-
GDOP-I Oxygen Analyzers for Industrial, Lab, and Research Environments
The portable oxygen analyzer is a portable oxygen purity meter to meet the needs of industries such as power, petrochemical and chemical. The product can measure the purity of oxygen.
With microcontroller as the core, it uses a high-precision oxygen sensor as the measurement unit, which is suitable for measuring oxygen content in various working conditions. It has the characteristics of intelligence, high accuracy, fast response speed and good stability.
-
GDP-311IR SF6 Gas Purity Tester (IR Method)
GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company.
-
GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)
GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.
-
GDSF-411WPD 3-in-1 SF6 Gas Analyzer(with pump)
GDSF-411WPD 3-in-1 SF6 Gas Analyzer is combined of SF6 humidity (dew point) test, SF6 purity test and SF6 gas decomposition product test. It integrates the functions that can only be achieved with three instruments in one instrument. One-time on-site measurement can complete the detection of all indexes, which greatly saves the gas in the equipment, at the same time reduces the workload of users and improves work efficiency.
-
GDLD-313IR SF6 Gas Leak Detector
GDLD-313IR SF6 Gas Leak Detector is updated model, which is infrared red type leak detector (NDIR technology). It is LCD display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute.
The smart quick intelligent test system is used, the software registering number 1010215, trademark registering number 14684781.
-
GDP-311CAW 3-in-1 SF6 Quality Analyzer
GDP-311PCAW SF6 gas quality analyzer is a portable device designed to measure SF6 gas purity, dew point, composition, CF4 content and air content.
-
GDQH-31H Portable SF6 Gas Recovery Device
GDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested.
At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV.
-
GDP-713PM SF6 Gas Dew Point Tester (Chilled Mirror Method)
GDP-713PM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection. The perfect combination of high-quality dew point sensor and intelligent electronic control technology makes it successfully applied to accurate measurement of dew point under various environmental conditions.
The dew point measurement is based on the principle of chilled mirror. The water vapor in the measured gas is condensed into water or frost on the mirror surface through semiconductor cold reactor cooling. When the two-phase equilibrium of water in the gas is reached, the temperature of the mirror surface is measured at this time, that is the dew point or frost point.
Compared with other forms of dew point meter, the chilled mirror dew point meter measures the dew point temperature more accurately, and at the same time has the characteristics of good measurement repeatability, stable and reliable measurement results, and easy operation.
GDP-713PM portable cooling method SF6 gas dew point meter is a standard instrument for humidity measurement in the fields of electric power, gas, meteorology, electronics, petroleum, chemical industry, measurement, etc. It is an ideal choice for establishing a humidity standard device.
-
GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer
At present, the UHV voltage level of 110KV and above uses SF6 gas-insulated enclosed GIS as the main primary equipment of the substation, the evaluation of GIS internal insulation status is mainly achieved by partial discharge detection method and SF6 gas chemical analysis method at home and abroad.
-
GDQH-601-50 SF6 Gas Recycling Machine
The model GDQH-601-50 is special machine of vacuumizing and filling device. It is suitable for SF6 electrical equipment, GIS manufacturer and research institute.
-
GDSF-311WP SF6 Dew Point and Purity Tester
GDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company.
-
GDQC-55A SF6 Gas Vacuuming and Filling Machine
GDQC-55A SF6 Gas Vacuuming and Filling Machine is mainly used for vacuuming and filling SF6 gas insulated electrical equipment in the manufacturing, use and scientific research departments.
It is suitable for SF6 electrical equipment, GIS manufacturer and research institute.