Transformer Amavuta ya gaz Chromatografiya Sisitemu yo gukurikirana kumurongo
GDDJ-DGA Transformer Oil Gas Analyser nigikoresho cyo kugenzura kumurongo wa gaze yashonze mumavuta ya transformateur ashingiye kubuhanga bwa chromatografiya.Ikosa rishobora kugenwa, kurekura integuza nkuko byagenwe binyuze muri sisitemu yo gusuzuma abahanga.
Igikoresho gikoresha uburyo bwo kugenzura ikoreshwa rya tekinoroji kandi ifite ibikorwa byo kwisuzumisha no kwikiza.Buri mikorere module ifite intege nke guhuza, imikorere yigenga, gufata imiterere ya rack, byoroshye kubungabunga injeniyeri.
●Kubungabunga neza, nta mpamvu yo gusimbuza gaze ya gaze.
●Kumurongo wo kumenya umurongo hamwe niterambere ryikura rya H2, CO, CO2, CH4, C2H4, C2H2, C2H6.
●Igishushanyo mbonera nuburyo bworoshye, byoroshye kubungabunga, hamwe no kwaguka kwinshi, birashobora kwinjizwa byoroshye mubindi bikoresho byo gukurikirana.
●Uburyo bwo gukora isuku yumubare wicyitegererezo, kugirango ugaragaze uko gaze yashonze mumavuta ya transformateur.
●Pompless vacuum degassing tekinoroji, ntabwo ikeneye pompe vacuum no kunoza kwizerwa no gutuza kwa sisitemu.
●Inkingi idasanzwe ya chromatografique, kugirango itezimbere urwego rwo gutandukanya gaze.
●Ikimenyetso kidasanzwe, kugenzura amakuru nukuri kandi yizewe, ibisubizo byikizamini byegeranye cyane na laboratoire.
●Igice cyigenga muri chassis kugirango igenzure ubushyuhe nubushuhe, kugirango ikureho akarere nigihe cyigihe.
●Hamwe namakuru menshi yo kubona amakuru neza, ifata △ -ε 24-mibare ya ADC na filteri ya digitale.Ikoresha kalibrasi yo gukusanya gukusanya porogaramu.
●Hamwe namakuru atandukanye yerekana nibibazo byuburyo, raporo nigishushanyo mbonera.Amakuru yamateka arashobora kubikwa kugeza kumyaka 10.
●Guhindura ibidukikije bikomeye, gukoresha neza ubukonje, ubushyuhe bwinshi, ubuhehere bwinshi, ahantu hirengeye.
●Ubushobozi bukomeye bwo kurwanya-kwivanga, guhuza amashanyarazi birashobora guhaza ibipimo bijyanye.
●Hamwe ninzego ebyiri zo gutabaza, ibimenyetso byo gutabaza birashobora koherezwa kure.
●Isesengura ryihuse, inzinguzingo ntarengwa ni iminota 40, irashobora gushyirwaho nabakoresha.
●Ikoranabuhanga ryuzuye ryo gusubiza peteroli, mugihe cyo gutesha agaciro, icyitegererezo cyamavuta ntigihuza na gazi itwara chromatogramu, gukoresha uburyo butandukanye bwo kugenzura, kugirango harebwe niba umubiri uhindura ibintu byerekana amavuta yujuje ibisabwa.
●Sisitemu ishimangiye sisitemu yo gusuzuma, ibisubizo bitangwa binyuze muburyo bunoze bwibipimo bitatu, uburyo bwa David triangle nuburyo bwa cube diagram.
●Hamwe nuburyo butandukanye bwitumanaho bwo kohereza amakuru, RS485, IEC61850, GPRS ihererekanyabubasha hamwe nubutumwa bugufi bikoreshwa muburyo bwo kohereza amakuru.
●Shyigikira Ethernet / optique ihuza, ihererekanyamakuru, igenzura ryibikoresho hamwe nibisobanuro hamwe na digitale yuzuye hamwe no kugenzura kure.
●Amavuta / gazi yimodoka ya Calibibasi nibikorwa byo gusukura imodoka birahari.
Ubushyuhe bwibidukikije | -40 ℃~+ 70 ℃ | ||
Ubushuhe bw’ibidukikije | Ubushuhe bugereranije 5-95% (nta condensation) | ||
Umuvuduko w'ikirere | 80kPa-110kPa | ||
Amashanyarazi | AC 220V ± 10%, 50Hz | ||
Gukurikirana ibice | H2, CO, CO2, CH4, C.2H4, C.2H2, C.2H6, H.2O, umuvuduko wo gukura no kwibanda | ||
Isesengura nigikorwa cyo gusuzuma | Gisesengura no gusuzuma amakuru yo gukurikirana ukoresheje uburyo butatu, uburyo bwa David triangle nuburyo bwa cube diagram.Umwimerere wa spekrogramu irashobora gutangwa. | ||
Min.Ukuzenguruka | 40-60mins, umukoresha-asobanuwe, asanzwe inshuro enye kumunsi. | ||
Uburyo bw'icyitegererezo | Amagare y'icyitegererezo, kugirango yerekane ibihe nyabyo bya gaze imbere. | ||
Gutandukanya uburyo bwa peteroli na gaze | Uburyo bwa Vacuum butesha agaciro, gutesha agaciro inshuro eshatu ubudahwema. | ||
Igihe cyo kubika amakuru | ≥ Imyaka 10 | ||
Ubwinshi bwa gaze | Ubwikorezi bwikorezi bwikorezi, ntibuhagarikwa umwaka wose.Nta mpamvu yo gusimbuza silinderi. | ||
Gukurikirana gaze | Urwego rwo gupima | Min.gutahura | Ikosa |
H2 | 2- 2000 ppm | 1 ppm | ± 10% |
CO | 5- 20000 ppm | 5 ppm | ± 10% |
CH4 | 0.2- 2000 ppm | 0.2 ppm | ± 10% |
C2H4 | 0.2- 2000 ppm | 0.2 ppm | ± 10% |
C2H6 | 0.2- 2000 ppm | 0.2 ppm | ± 10% |
C2H2 | 0.2- 2000 ppm | 0.2 ppm | ± 10% |
CO2 | 25- 20000 ppm | 25 ppm | ± 10% |
H2O | 1 - 800 ppm | ||
Ubushyuhe bwa peteroli | -40 ℃ ~ 200 ℃ | ||
Ubwinshi bwikirere | 0.2-15% | ||
Hydrocarubone yose | 1 - 8000 ppm | ||
Guhagarara (ikosa ryo gupima) | Mugihe kimwe cyo kwipimisha, ikosa ntirenza 10% kurugero rumwe rwamavuta.(kwibanda cyane) | ||
Icyiciro cya IP | IP66 |
Uburebure | 0003000m |
Ubushyuhe bwibidukikije | -10 ℃ ~ + 45 ℃ (mu nzu);-40 ℃ ~ + 70 ℃ (hanze) |
Icyiza.itandukaniro ry'ubushyuhe bwa buri munsi | 25 ℃ |
Icyiza.ugereranije n'ubushuhe | 95% (impuzandengo ya buri munsi);90% (impuzandengo ya buri kwezi) |
Umuvuduko w'ikirere | 86kPa ~ 106kPa |
Ubushobozi bwo kurwanya ihungabana | Kwihuta gutambitse 0,30g;kwihuta guhagaritse 0.15g |
Ibidukikije | Kwinjiza mu nzu.Icyumba kigomba kuba gifite ibyuma bifata ibyuma bikonjesha, nta gukingira, nta ngamba zo kurwanya static. |
Ikigereranyo cy'amashanyarazi (AC) | 220V / 100V, ikosa ryemewe ± 20% (guhuza), igipimo cyo kugoreka ingufu zose ≤8%. |
Ikigereranyo cy'amashanyarazi (DC) | 220V / 110V, byemewe gutandukana range 20%. |
Ikigereranyo cya AC voltage | 57.7V / 100V / 220V, ubushobozi burenze urugero ni 1.2 inshuro ya voltage yagenwe, coefficient ≥2. |
Ikigereranyo cya AC | 1A / 5A, ubushobozi burenze urugero ni 1,2 yikigereranyo cyagenwe, gikomeza gukora, coefficient ≥3. |
Ikigereranyo cyagenwe | 50Hz, ikosa ryemewe -5% ~ + 5%. |
Amashanyarazi
Amashanyarazi ya sisitemu yo kugenzura imiterere ya sitasiyo agomba kuba afite umutekano kandi wizewe, kandi ibikoresho byo kugenzura sitasiyo bigomba gukoreshwa na 220VAC idahagarara (UPS).Buri gice cyo kugenzura murwego rwibikorwa gikoreshwa na sisitemu ya ACV 220V.
Kurinda inkuba, guhagarara, kurwanya-kwivanga
Sisitemu yo kugenzura imiterere ya sisitemu igomba kugira ingamba zo gukingira umuyaga mwinshi.
Nta gride itandukanye ya sisitemu yo kugenzura imiterere.Ukurikije ihame rya "point point imwe", insinga yubutaka ihujwe ningingo imwe ya gride nyamukuru ya podiyumu.
Igikoresho cyo gukingira ingufu zirenze urugero kizashyirwa kuri 220V AC itanga amashanyarazi, umurongo witumanaho nu mpera yambere yumurongo wubutaka, kandi ibipimo byokwirinda bigomba guhuza nigipimo cyimikorere yibikoresho.
Chassis, kabine na kabili ikingira urwego rwa sisitemu yo kugenzura imiterere igomba guhagarara neza.Isano iri hagati yuburyo butunganijwe bwa sisitemu yo kugenzura imiterere, ihuriro riri hagati yimikorere na sitasiyo igenzura sitasiyo, kandi isano iri hagati yicyambu cyitumanaho ryibikoresho igomba kuba yonyine.
Igikoresho cyashyizwe mucyumba kitagira amashanyarazi akingira.Igikoresho ubwacyo kigomba kuba cyujuje ibisabwa kugirango anti-electromagnetic yivanga hamwe nimbaraga za electrostatike.Mugihe umurabyo urenze, gukora birenze urugero hamwe namakosa magufi yibikoresho byibanze, ibikoresho ntibishobora gukora nabi, kandi ibikoresho byose bigomba kuba byujuje ibi bikurikira birwanya kwivanga:
1) Kubisohora amashanyarazi, bihuye na GB / T 17626-4-2 icyiciro cya 4.
2) Kumirasire yumuriro wa electromagnetic, ihuye na GB / T 17626-4-3 icyiciro cya 3.
3) Kubyihuta byihuse, bihuye na GB / T 17626-4-4 icyiciro cya 4.
4) Kubyiyongera, bihuye na GB / T 17626-4-5 icyiciro cya 3.
5) Kugirango habeho kwinjiza amashanyarazi, bihuye na GB / T 17626-4-6 icyiciro cya 3.
6) Kumashanyarazi yumurongo wa electromagnetic, ihuye na GB / T 17626-4-8 icyiciro cya 4.
7) Kubijyanye na pulse electromagnetic yumurima, ihuye na GB / T 17626-4-9 icyiciro cya 5.
8) Kubijyanye na magnetiki ihindagurika yumuriro, ihuye na GB / T 17626-4-10 icyiciro cya 5.
9) Kubireba imivumba ihindagurika, ihuye na GB / T 17626-4-12 icyiciro cya 2 (icyapa cyerekana).
Oya. | Izina ryibikoresho | Ibisobanuro | Qty | Ongera wibuke |
1 | Transformer Amavuta ya gaz Sisitemu yo gukurikirana | 535 * 600 * 1100 | 1 | |
2 | Flange | Ukurikije icyambu cya transformateur | 2 | |
3 | Umuyoboro w'icyuma | Φ6 * 30M | 1 | |
4 | Fibre optique | Multimode 4-yibanze, 200M | 1 | |
5 | Agasanduku ka Terminal | 2 | ||
6 | Gusimbuka | SC-SC | 2 | |
7 | Guhindura fibre | Multimode | 1 | |
8 | Umugozi wa Ethernet | 0.5M | 2 | |
9 | Kuramo | M12 * 1.25M, Φ6 | 2 | |
10 | Umugozi wagutse | M10 * 100 | 4 | |
11 | Urufunguzo rw'Inama y'Abaminisitiri | 2pc | 1 | |
12 | Ikarita | 4pcs + imigozi myinshi ya nylon | 1 | |
13 | Umuyoboro w'icyuma | Φ3 * 2M | 1 | |
14 | Umuyoboro wokwirinda nibindi bice | Umuyoboro wokwirinda Φ6 * 2M 4pcs, Au kaseti 50 * 25M 1roll, ibyuma bidafite ingese 8 * 32 2pcs | 1 |