AC Ikigereranyo Cyamashanyarazi Gishyiraho GIS
●Guhindura
●Sisitemu ya GIS
●SF6
●Intsinga
●Bushing
●Imashini
●CT / PT
●Ibindi bikoresho byubushobozi
●Ubushyuhe buke buzamuka ku mutwaro wagenwe.Imashini yumye cyangwa yamavuta, imbaraga za mashini nyinshi, izirinda neza, nziza kandi yizewe.
●Ubushobozi bwo guhinduranya inkomoko yo kugenzura.Kurinda gukomeye, gutekana kwiza.Hamwe nuburyo bwinshi bwo gukora, byoroshye gukora.
●Hamwe na 220V cyangwa 380V icyiciro kimwe cyingufu, cyoroshye kumashanyarazi.
●Ibikoresho byoroshye.Ubwoko butandukanye bwa reaktor kubushake, bujuje ibyangombwa bisabwa.Imikorere myinshi, igiciro cyiza.
●Ikigereranyo gisohoka voltage: gishingiye kubintu bitandukanye byo kugerageza.
●Inshuro zisohoka: 20- 300Hz.
●Waveform: sine yuzuye, THD <1.0%.
●Icyiza.ubushobozi: 1000kVA no munsi.
●Inshingano Yumwanya: Gukomeza akazi 15mins inshuro imwe kumashanyarazi yuzuye.(cyangwa abakiriya.)
●Guhindura inshuro nyinshi: 0.1Hz, guhungabana <0.05%.
●Amashanyarazi: 380 / 220V ± 15% / 50Hz ± 5%.
GDTF-108/108 | |
Injira ya voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0-108 |
Ubushobozi (kVA) | 108 |
Ingano yo gusaba | 31500kVA cyangwa munsi |
35kV ihinduranya ingufu | |
35kV yameneka yamashanyarazi na bisi ya bisi, insulator | |
10kV (300 mm²) umugozi 2000m | |
35k V (300 mm²) umugozi 500m | |
Iboneza nyamukuru | 5kW Impinduka zumuvuduko winkomoko 1 gushiraho |
5kVA Transformator ishimishije 1 set | |
Imashini 27kV / 1A 4sets | |
Gutandukanya ubushobozi bwa 100kV | |
GDTF-216/216 | |
Injira ya voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0-216 |
Ubushobozi (kVA) | 216 |
Ingano yo gusaba | 110kV Kumena inzitizi hamwe na bisi ya bisi |
110kV GIS | |
35kV (300 mm²) umugozi 1500m | |
10kV (300 mm²) umugozi wa 3km | |
110kV Ihinduranya ryuzuye | |
Iboneza nyamukuru | 10kW Impinduka zumuvuduko winkomoko 1 gushiraho |
10kVA Transformator ishimishije 1 set | |
Imashini 54kV / 1A 4sets | |
Gutandukanya ubushobozi bwa 200kV | |
GDTF-270/270 | |
Injira ya voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0-270 |
Ubushobozi (kVA) | 270 |
Ingano yo gusaba | 110kV GIS na transformateur |
110kV GIS na transformateur | |
35kV (300 mm²) umugozi 2km | |
Iboneza nyamukuru | 15kW Impinduka zumuvuduko winkomoko 1 gushiraho |
15kVA Transformator ishimishije 1 set | |
Imashini 54kV / 1A 5sets | |
Gutandukanya ubushobozi bwa 300kV | |
GDTF-400/400 | |
Injira ya voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0-400 |
Ubushobozi (kVA) | 400 |
Ingano yo gusaba | 220kV GIS na transformateur |
10kV (300 mm²) umugozi wa 4km | |
35kV (300 mm²) umugozi 1km | |
Iboneza nyamukuru | 20kW Impinduka zingana inshuro 1 gushiraho |
20kVA Transformator ishimishije 1 set | |
Imashini | |
Gutandukanya ubushobozi bwa 400kV | |
GDTF-520/260 | |
Injira ya voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0-260 |
Ubushobozi (kVA) | 520 |
Ingano yo gusaba | 110KV Kumena inzitizi hamwe na bisi ya bisi |
110kV GIS | |
110kV (300 mm²) umugozi 800m | |
35kv (300 mm²) umugozi wa 3km | |
10kV (300 mm²) umugozi 6km | |
110kv Impinduka zuzuye | |
Iboneza nyamukuru | 25kW Impinduka zingana inshuro 1 gushiraho |
25kVA Transformator ishimishije 1 set | |
Imashini 65kV / 2A 4sets | |
Gutandukanya ubushobozi bwa 300kV | |
GDTF-500/500 | |
Injira ya voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0-500 |
Ubushobozi (kVA) | 500 |
Ingano yo gusaba | 220kV cyangwa munsi ya CT / PT |
220kV cyangwa munsi ya bushing | |
220kV cyangwa munsi ya Insulator, guhagarika | |
220kV cyangwa munsi yamashanyarazi | |
220kV cyangwa munsi yigikoresho cyo kubika | |
Iboneza nyamukuru | 20kW Impinduka zingana inshuro 1 gushiraho |
20kVA Transformator ishimishije 1 set | |
Imashini 125kV / 1A 4sets | |
Gutandukanya ubushobozi bwa 500kV | |
GDTF-600/600 | |
Injira ya voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0-600 |
Ubushobozi (kVA) | 600 |
Ingano yo gusaba | 110kV (300 mm²) umugozi 800m |
35kv (300 mm²) umugozi 110m | |
35-220kV GIS, impinduka, insulator | |
Iboneza nyamukuru | 30kW Impinduka zumuvuduko winkomoko 1 gushiraho |
30kVA Impinduka ishimishije 1 seti | |
Imashini 120kV / 1A 5sets | |
Gutandukanya ubushobozi bwa 600kV | |
GDTF-800/800 | |
Injira ya voltage (V) | 380 |
Umuvuduko w'amashanyarazi (kV) | 0-800 |
Ubushobozi (kVA) | 800 |
Ingano yo gusaba | 110kV (300 mm²) umugozi 800m |
220kv (300 mm²) umugozi 500m | |
35-500kV GIS, impinduka, insulator | |
Iboneza nyamukuru | 40kW Impinduka zumuvuduko winkomoko 1 gushiraho |
40kVA Transformator ishimishije 1 set | |
Imashini 200kV / 1A 4sets | |
Gutandukanya ubushobozi bwa 800kV |