Ibyavuye mu bushakashatsi bwakozwe mu gusohora igice mu bikoresho bya GIS byerekana ko bitewe n’ingufu zingana na dielectric ya gaze ya SF6, igihe cyo gusohora igice cyinshi muri gaze yumuvuduko mwinshi wa gaze ya SF6 mubikoresho bya GIS ni gito cyane, hafi ya nanosekondi, na umutwe wumuraba ufite igihe gito cyane.Igihe cyo kuzamuka ni nka 1ns gusa.Ubu bwoko bwimisemburo ihanamye hamwe nigihe gito cyane, harimo ibimenyetso bigera kuri GHz, bizabyara amashanyarazi ya electronique atembera kumashanyarazi ya GIS.Umuvuduko mwinshi wo gusohora pulse unyura mumigozi yubutaka, kandi isanduku ihujwe nubutaka.Yerekana umuvuduko mwinshi wa voltage kandi ikabyara amashanyarazi yumuriro mumwanya ukikije.Gusohora igice bizatera kandi kwiyongera gutunguranye k'umuvuduko wa gazi y'umuyoboro, kubyara imiraba miremire cyangwa ultrasonic waves muri gaze y'ibikoresho bya GIS, kandi imivumba itandukanye y'amajwi, nk'imivumba miremire, imiraba ihindagurika n'imiraba yo hejuru, igaragara ku cyuma Igikonoshwa.Gusohora igice mubikoresho bya GIS birashobora kandi gutera gaze ya SF6 kubora cyangwa gusohora urumuri.Izi mpinduka zifatika na chimique ziherekejwe no gusohora igice nizo shingiro ryo gutahura kumurongo ibikoresho bya GIS.Uburyo bwo gutahura igice gisohoka mubikoresho bya GIS birashobora kugabanywa mubice bibiri: uburyo bwo kumenya amashanyarazi nuburyo bwo kumenya amashanyarazi.uburyo, uburyo bwo gutahura ibicuruzwa bya SF6.
GDPD-300UF UHF Ikwirakwiza Igice
HV Hipot GDPD-300UF UHF isohora igice cyo gusohora igice (igikoresho cyo gusohora igice cya UHF) irashobora gukoreshwa cyane mugutahura igice cyogusohora amashanyarazi, harimo amashanyarazi menshi, impeta nyamukuru, impinduramatwara / amashanyarazi, impinduka (harimo na leta ya Insulation yumye ibikoresho nka transformateur), GIS, imirongo yo hejuru, insinga, nibindi, urugero rwo gusohora ibikoresho byamashanyarazi bipimwa nibipimo bikurikira.
Ibicuruzwa biranga UHF Igice cyo Gusohora Igice
Shiraho ibyuma bitandukanye kugirango ugere kubice bisohora ibikoresho hafi ya byose byamashanyarazi;
Umukoresha-ukoresha-imashini yimashini yorohereza imicungire yamakuru yibikoresho bitandukanye, harimo no gukurikirana amateka yamakuru, amateka atambitse kandi ahagaritse, kandi akamenya 360 ° gusuzuma neza ibikoresho biri kugeragezwa;
Yubatswe muri sensor ya ultrasonic na voltage yubutaka bwigihe gito (hano bita TEV) sensor, ishobora guhuzwa na sensor idasanzwe nka transformateur, GIS, imirongo yo hejuru, ninsinga;
Uburyo budasobanutse bwo gutahura bwakoreshejwe, nta kunanirwa kw'amashanyarazi bisabwa mu gihe cy'ikizamini, kandi nta yandi masoko y’umuvuduko ukabije ukenewe, bikaba byoroshye gukoresha kuruta ibisanzwe byifashishwa mu gusohora igice;
Ikizamini cyagutse ni 30kHz ~ 2.0GHz, ikwiranye nihame ryo gutahura imirongo itandukanye.