Ibisobanuro byubushobozi & Tan Delta Ikizamini
capacitance & tan delta tester nuburyo bwibanze mugupimisha insulasiyo, irashobora kugenzura neza kwangirika kwinshi muri rusange kwangirika kwibikoresho byamashanyarazi, hamwe nubusembwa bwaho.Ubushobozi butandukanye bwikora capacitance & tan delta tester nigikoresho cyo hejuru cyibizamini byigenga byakozwe na HV Hipot.Ikoreshwa cyane mugupima ubushobozi & tan delta tangent hamwe nubushobozi bwibikoresho bitandukanye byamashanyarazi menshi mumashanyarazi, insimburangingo nizindi mirima cyangwa muri laboratoire.Ubushobozi butandukanye bwa capacitance & tan delta tester irashobora kubona neza kwangirika kwubushuhe muri rusange hamwe nubusembwa bwibanze bwibikoresho byamashanyarazi.Irakoreshwa cyane muri capacitance & tan delta gupima impinduka, transformateur, insinga z'amashanyarazi nibindi bikoresho mubikorwa byingufu.
GD6800 capacitance & tan delta igerageza
Gushyira mu bikorwa ubushobozi & tan delta
capacitance & tan delta ikoreshwa cyane mubikorwa byo gukora amashanyarazi, gushyiramo ibikoresho byamashanyarazi, guhererekanya no kugerageza gukumira.Igikoresho nacyo kibereye gupima tgδ nubushobozi bwibikoresho byamashanyarazi yumuriro mwinshi mumahugurwa, laboratoire hamwe nubushakashatsi bwubumenyi;irashobora gukoreshwa mugupima capacitance & tan delta yamavuta ya insuline mugihe ifite ibikombe byamavuta.
Ibiranga ubushobozi & tan delta igerageza
Igikoresho ni imiterere ihuriweho hamwe na capacitor yubatswe kandi ikongerera ingufu amashanyarazi, ingano ntoya, uburemere bworoshye, byoroshye gutwara, gukora byoroshye, gupima byikora, gusoma byihuse, nta guhinduka, ibisobanuro bihanitse, hamwe nubushobozi bukomeye bwo kurwanya kwivanga.
Imiterere ya capacitance & tan delta igerageza
Igikoresho gifite ibikoresho byumuvuduko mwinshi wumuvuduko ukabije, kandi byafashe ingamba zo kurinda umutekano nko gufunga zeru no gufunga inkuba.Mugihe cyikizamini, ongeramo mu buryo butaziguye amashanyarazi ya 220V AC, urashobora gusohora 2KV, 5KV, 10KV urwego rutandukanye rwa voltage ndende, imikorere iroroshye kandi ifite umutekano.
Imikorere ya capacitance & tan delta igerageza
Iki gikoresho nigikoresho cyibanze cyane cyo gupima mu buryo bwikora ubushobozi bwa capacitance & tan delta yibikoresho bitandukanye byamashanyarazi menshi mumashanyarazi, insimburangingo nizindi nzego, kandi birashobora kwemeza gupimwa neza mugihe amashanyarazi akomeye.Igikoresho cyongeyeho imikorere yubushinwa, imikorere iroroshye kandi yoroshye.Igikorwa kimwe, microcomputer ihita irangiza inzira yose yo gupima.Nibikoresho byiza bya capacitance & tan delta ibikoresho byo gupima.
Uburyo bwo gupima ubushobozi & tan delta
Ibikoresho by'amashanyarazi bifite ingufu nyinshi zidafite ishingiro cyangwa zidahagaze neza birashobora gupimwa nuburyo bwo gukoresha insinga imbere.