GDJB-6000D Sisitemu yo Kwirinda Ikizamini cyo Kurinda Sisitemu
GDJB-6000D ifite ibikoresho byongerera imbaraga imbaraga kandi bishingiye kuri platform ikomeye ya PowerPC + X86.Ifata modular igishushanyo kandi ifite imikorere ikomeye, isobanutse neza, ingano ntoya nuburemere bworoshye.Irashobora kugerageza imikorere nigikorwa cyo guhuza ibice, ibikoresho byo gukingira ibyuma, gupima no kugenzura, ibikoresho byubwenge nibindi bikwiranye ninganda zamashanyarazi, insimburangingo, ibice bitandukanye byubushakashatsi bwa siyansi ninganda zikora ibikoresho.
●Module y'Ikizamini Cyubwenge
Ubwenge bwikigereranyo cyicyitegererezo cyo guhindura kirashyigikiwe.Ibintu byikizamini birashobora kongerwaho kubushake mugihe cyibizamini hanyuma bikabikwa nkibishobora gukoreshwa dosiye yumushinga wikizamini kugirango tunoze neza ikizamini mugice cyanyuma cyo kugenzura no kurandura.
●Ikizamini cyikora
Hamwe no kurinda kurubuga no kurinda ibyuma byikora byikora, ibizamini byose byigikoresho kimwe cyo kurinda birashobora kurangizwa nurufunguzo rumwe.
●Uburyo bwinshi bwo gusikana
Gushyigikira amplitude, icyiciro, inshuro, impedance, vector, urukurikirane, nimbaraga bikorwa nigeragezwa ryintoki cyangwa ryikora, binashyigikira ikizamini cyimpinduka zikurikije uburyo bwo gutondekanya, kunyerera no guhuza.
●Virtual terminal yerekana ishusho
Shyigikira ibikorwa bya terefone igaragara yerekana imikorere, amakuru atemba arasobanutse.
●Kohereza no kwakira ubutumwa icyarimwe
Shyigikira IEC61850-9-1, IEC61850-9-2 na GOOSE optique yubutumwa bwa digitale.Ikimenyetso cya GOOSE gishobora koherezwa no kwakirwa mu bwigenge, kandi gishobora no kohereza no kwakira na interineti ya optique ya Ethernet hamwe na IEC 61850-9-2.
●FT3 / Yaguwe FT3
Shyigikira FT3, FT3 kwaguka na DL / T 282 ubutumwa busohoka, kandi ushyigikire 2M / 4M / 6M / 8M / 10M igipimo cya baud igipimo cya UART hamwe na 5M / 10M / 20M kodegisi ya Manchester.
●Ikizamini kidasanzwe
Hamwe nubutumwa bugereranya ubutumwa budasanzwe, burashobora kwigana ubudasanzwe mubwiza, kohereza amajwi ya jitter, gutinza ibintu bidasanzwe, gutakaza paki, bivuye ku ntambwe, numero yumubare usimbuka, uburyo bwo kubungabunga, ihinduka ryibintu bya leta nibindi bizamini.
●Gukina amakosa
Shyigikira amakosa yo kwigana hamwe na format ya COMTRADE imikorere yo gukina.
●Serivisi ya MMS
Hamwe nimikorere yo gusoma no kwandika MMS, irashobora gusoma no kwandika ibikoresho byubwenge bya IED nibindi bisobanuro byamakuru.
●Guhuza igihe no gutanga igihe
Hamwe nimikorere ya trigger syncronique, inkunga yo kugera kuri antenne ya GPS / BD mugihe cyo guhuza igihe, inashyigikira IRIG-B, PPS na PTP 1588 uburyo bwigihe kandi irashobora gushyigikira ibisohoka hanze IRIG-B, PPS na PTP 1588 igihe cyo gutanga ibimenyetso.
●Guhuza cyane binini yinjiza nibisohoka
Ingano yinjiza irakora kandi ihindagurika ihuza imiterere, kandi ubwoko bwinjiza hamwe ninjiza ya voltage ihita imenyekana.Imiyoboro yitandukanije, hamwe na polarite ihinduranya hamwe no gutabaza.
●Kwakira ubutumwa no gusesengura
Hamwe n'ubutumwa bwo kwakira no gusesengura imikorere, ubutumwa bwakiriwe burashobora gufungurwa na ZHNPA yo gusesengura cyangwa kohereza hanze.
●Uburyo bumwe bwa fibre
Icyambu cya optique gishyigikira fibre imwe hamwe no kwakira fibre imwe kandi igashyigikira ibizamini bya optique.
●Kugereranya ibimenyetso bito
Ifite ibikoresho bigereranya bito bito byerekana ibimenyetso, bishyigikira inzira 12 igereranya ibimenyetso bito byinjira, irashobora gupima -7V ~ 7V AC voltage, igashyigikira inzira 12 igereranya ibimenyetso bito bito, kandi ishobora gusohora -7V ~ 7V AC voltage.
●Gukoraho
Bifite ibikoresho bya 10.4 santimetero ndende yerekana kwerekana gukoraho.
●Umuyoboro udafite insinga
Tanga imikorere yikizamini cya kure, hamwe na module ya WiFi, uyikoresha.
Icyambu cy'itumanaho IEC 61850 | |
Imikorere | Iboneza byose bya IEC 61850 9-1 / 9-2 SMV yohereza, kwakira cyangwa kwanduza GOOSE no kwakira |
Ubwoko bw'imbere | LC icyambu |
Umubare | Ibice 8, ibice 6 * 100M ihuza n'imiterere, 2 * * 100 / 1000M |
Uburebure bwumuraba | 1310nm |
Icyambu cy'itumanaho IEC 60044 | |
Imikorere | GB / T 20840.8, DL / T 282, Q / GDW441 ubutumwa bwakira no kohereza |
Ubwoko bw'imbere | ST |
Umubare | 6 * kohereza interineti, 2 * kwakira interineti |
Icyiciro | |
Urwego | 0 ~ 360° |
Ukuri | ±0.1° |
Icyemezo | 0.1° |
Inshuro | |
Urwego | 0 ~ 1000Hz |
Ukuri | <±0.001Hz (0 ~ 65Hz) <±0.01Hz (65 ~ 450Hz) <±0.02Hz (450 ~ 1000Hz) |
Icyemezo | 0.001Hz |
Igihe | |
Urwego | 10ms ~ 9999.999s |
Icyemezo | 1ms |
Binary itumanaho | |
Umubare | 8 bibiri, Birashobora guhuzwaguhuza ubusa hamwe nubushobozi bushoboka (0 ~ 250V) |
Binary itumanaho | |
Umubare | Ibice 6, bibiri byombi bisohoka byihuse |
Ubushobozi bwo kumena | DC250V /0.5A |
Igihe cyo gusubiza | <100us |
Guhuza | |
Ubwoko bw'imbere | GPS / BD ANT;Ikimenyetso cya optique ya IRIG-B / PPS;Ikimenyetso cy'amashanyarazi IRIG-B / PPS;IEEE 1588 |
Umubare | 1 * GPS / BD ANT; 2 * IRIG-B / PPS ikimenyetso cya optique: 1 * guhuza igihe, 1 * gutanga umwanya; Byombi * IRIG-B / PPS ikimenyetso cyamashanyarazi: 1 jyenyine * igihe cyo guhuza, 1 jambo * igihe cyo gutanga; 1 babiri * IEEE 1588 |
Umuyoboro udafite insinga | |
Ubwoko bw'imbere | WIFI |
Kwihuza | |
Ubwoko bw'imbere | 100M Icyambu cya Lan, RJ45 |
Umubare | Ibice 2 |
Kugereranya ibimenyetso bito byinjira | |
Ubwoko bw'imbere | Gucomeka mu ndege, voltage ya AC |
Umubare | Umuyoboro 12 |
Kugereranya ibimenyetso bito bisohoka | |
Ubwoko bw'imbere | Gucomeka mu ndege, voltage ya AC |
Umubare | Umuyoboro 12 |
Amashanyarazi | |
Umuvuduko | AC / DC 220V, Biremewe gutandukana: -20% ~ 15% |
Inshuro | 47 ~ 65Hz |
USB Imigaragarire | |
Umubare | Ibice 2 |
Ibidukikije | |
Ubushyuhe bwo gukora | -10℃~ 50℃ |
Ubushuhe | ≤95%,kudahuza |
Abandi | |
Ibiro | 5.5 kg |
Igipimo | 146×390×212mm (L.×W×H) |
Imigaragarire kumurongo | RJ45 |
Erekana | 10.4 santimetero ibara ryukuri LCD ikoraho |