Ikizamini cya GDYZ-302W Icyuma cya Oxide Arrester (MOA)
1) Amashanyarazi yamenetse, AC yamashanyarazi
Urwego | Icyemezo | Ukuri |
0.000mA~1mA | 1uA | ±1% rdg ± 8dgt |
1.00mA~10.00mA | 0.01mA | |
10.0mA~100.0mA | 0.1mA | |
100mA~300mA | 1mA |
)
Nibura shingiro ryibanze ryinjiza | Hejuru ya 3% ya buri cyiciro |
Ukuri | 1% rdg ± 8dgt (± AC iriho ubu) |
Imikorere | Mugupima ibyuzuye byafashwe na zinc oxyde, birashobora gucirwa kumurongo niba ifatwa rya zinc oxyde yangiritse, kandi irashobora no gukoreshwa nka ultra-precision clamp-on metero yamenetse. |
Amashanyarazi | Abashitsi: DC 7.4V 2000mAh bateri ya lithium yumuriro, bateri hafi 8.4V yuzuyeDetector: DC 7.4V 2600mAh bateri ya lithium yumuriro, bateri igera kuri 8.4V yuzuye |
Uburyo bwo Kwipimisha | Clamp-on CT |
Urwego rwo gupima | AC 0.000mA~300mA (Agaciro nyako) |
Icyiza.imyanzuro | 1μA |
Ibipimo bifatika | ±1% rdg±8dgt (23℃ ±5℃, munsi ya 80% RH) |
Itumanaho ridafite insinga | 433MHz itumanaho ridafite umugozi |
Intera yoherejwe | 30m |
Uburyo bwo kwerekana | Ibara rya santimetero 3,5;ahantu herekanwa: 71mm×53mm |
Ingano y'ibikoresho | Uwakiriye: 195mm×100mm×45mm;Detector: 208mm×131mm×90mm |
Uburemere bwibikoresho | Uwakiriye: hafi 400g;detector: hafi 1220g,Igiteranyo: hafi 7000g (harimo inkoni zo kubika hamwe nibikoresho) |
Ingano ya Clamp | φ40mm |
Igipimo cy'icyitegererezo | Inshuro 2 / s |
Itariki yo kubika | Amatsinda 200, ikimenyetso "HOLD" yerekana mugihe cyo kubika. |
Gufata amakuru | Muburyo bwikizamini, kanda urufunguzo rwa HOLD kugirango ubike amakuru kandi ubike amakuru, ikimenyetso "HOLD" kirerekanwa, hanyuma ukande urufunguzo rwa HOLD kugirango uhagarike. |
Kugenzura amakuru | "SOMA" ikimenyetso cyerekana ko amakuru yabitswe ashobora guhindurwa hejuru no hepfo. |
Kurengerwa | “OL” yerekana kurengerwa ibipimo. |
Nta kimenyetso | Iyo uwakiriye yakiriye atabonye ibimenyetso byerekana, imiterere yubu ya detector ntishobora kugaragara. |
Kuzimya | Igikoresho kizahita kizimya nyuma ya 10min kugirango ubike bateri. |
Umuvuduko wa Batiri | Iyo voltage ya batiri iri munsi ya 7.8V, yerekana ko igihe kigeze cyo guhindura bateri. |
Umuvuduko wumurongo | 35kV no munsi |
Ubushyuhe n'ibidukikije | -20℃ ~40℃; hepfo80% Rh |
Ububiko | -20℃ ~60℃;hepfo70% Rh |
Kwivanga | No 433MHz Kwerekana ibimenyetso byinshyi |
Ingano yinkoni | Ibice 4 byo gusunika-buto ya telesikopi izenguruka (leta yaguye 5m, ifunze leta 1.5m, diameter yo hanze φ44mm) |
Imbaraga zo gukumira | Inkoni imwe ikingira AC110kV / rms, igikonoshwa cya HVicyumahagati yicyuma: AC1000V / rms |