Sisitemu ya GD-4138H
GD-4138H Sisitemu Yumurongo Wibikoresho Byibikoresho Sisitemu nigikoresho cyingenzi cyo kubungabunga ubwoko bwose bwinsinga.Nibikoresho bihuye bishobora gukurikirana, kumenya insinga zubutaka, hamwe no gupima intera ikabije hamwe na HV generation.Nkuko ari igikoresho cyimukanwa, biroroshye gutwara kurubuga.Niba acoustic locator ikoreshwa hamwe, irashobora kumenya umwanya wukuri wa kabili ya point point.
Porogaramu ni umugozi wubutaka, insinga zo mu kirere, insinga z'amashanyarazi, umugozi waho, insinga y'itumanaho na fibre fibre.
●Impedance nyinshi flash-over amakosa
●Kumeneka kwinshi
●Hejuru / hasi irwanya imbaraga
●Ikosa rigufi
●Ikosa rifunguye
●Guhuza nabi / Guhagarika
●GD-4138H ikadiri nyamukuru (Igikoresho cyo guhuza, icyuho cya Sphere, generator ya HV imbere)
●GD-4133 Ikigeragezo cyinshi cya kabili
●GD-4132 Umugozi wibeshya
●Uburyo bwinshi butandukanye: uburyo buke bwa voltage pulse, uburyo bwa pulse yubu, uburyo bwinshi bwa pulse: icyitegererezo cyubu, ibisohoka DC.
●Ubwoko bwibimenyetso byerekana: Uburyo bwa DC arc bwo kwerekana, icyitegererezo cyubu, icyitegererezo cya voltage, pulse ya voltage nto.
●Shakisha vuba kandi werekane imbaraga nke-zidashobora kumeneka, amakosa ya flashover yamakosa ya 220V ~ 220KV yumuriro wamashanyarazi.
●Nta mpamvu yo kubikorainsinga zigoye zo kugerageza kurubuga.Uburyo bwose bwikizamini bwahinduwe mu buryo bwikora binyuze mumbere ya voltage yimbere igenzurwa nintege nke.
●Imashini ihuriweho ninshi yihuta cyane ya generator, amashanyarazi yihuta cyane ya capacitor, arc stabilizing unit hamwe no kubona ibimenyetso bitandukanye murimwe, byoroshye gukora sisitemu yibibanza.
●Inzego nyinshi zisohoka hejuru ya voltage ihinduranya, byose bigenzurwa imbere na voltage yimbere imbere intege nke, umutekano kandi wizewe.
●Imiterere yibikoresho bifata plastike ikomeye cyane.Urubanza ni agasanduku ko hanze yibikoresho hamwe nagasanduku kohereza ibikoresho.Nibyiza kwimura, kandi birashobora gutwarwa no kwimurwa mugihe igifuniko gifunze.
●Umwanya wo gutandukanya impulse isohoka: Intege nke zo kugenzura solenoid valve icyuho cyikirere, igihe cyo gusohora kirashobora guhinduka kuva kumasegonda 3 kugeza 12, kandi muffler yagenewe byumwihariko kugirango ihuze ibisabwa na mute kugirango unanirwe insinga mugitangira.
●Ibikoresho bifite uruziga rwuzuye.Nyuma yikizamini cyamakosa kirangiye, voltage ndende irashobora kuzimya kanda buto kumwanya wo gusohora kugirango uhite usohoka.
●Intera yo gupima intangiriro irashobora gutanga intera yo gupima kugera kuri 0.4m, kandi agace gahumye gapima ni nto, kagira akamaro cyane cyane kumakosa yanyuma-ninsinga ngufi.
●Ibisohoka byose bisohoka mubikoresho byateguwe kumwanya winyuma kugirango byoroshye insinga, kandi igishushanyo mbonera cyuburyo butandukanye bwo gushushanya cyashizwe kumurongo wibikorwa, gishobora gukoreshwa byoroshye nabantu badafite uburambe.
●Hasi yibikoresho bifite ibyuma 4 bifite imbaraga zo kunyerera cyane, bishobora gusunikwa no kubikwa kugirango bibike.
●Urutonde rwakoresha rukoresha 7-santimetero nini ya LCD ifite 160 ° yo kureba, kandi ibyerekanwe birakungahaye kandi bitangiza.
●Umubare munini wamafirime arashobora kubikwa muri host, kandi amakuru yumurongo ashobora gutumizwa no koherezwa hanze ukoresheje U disiki.
●Umucumbitsi arashobora guhuzwa na mudasobwa (desktop cyangwa ikaye) kugirango itumanaho kumurongo.
●Iyo nyiricyubahiro adafite ibikorwa muminota 2, itara ryinyuma rizacika intege;niba nta gikorwa cyiminota 10, kizahita gifunga kugabanya ingufu zikoreshwa;iyo bateri iri munsi ya volvoltage, igikoresho nacyo kizahita gifunga kugirango kirinde bateri.
●Nyiricyubahiro afite bateri yuzuye ya polymer lithium-ion kandi ifite ibikoresho byabugenewe bya batiri ya lithium kugirango itange uburyo bwizewe bwo kwishyuza.
●Imashini yose ifata ihererekanyabubasha ryimiterere yimiterere yimiterere, iroroshye kandi irakomeye, cyane cyane ikwiriye kubakwa.
| Icyitegererezo | GD-4138L | GD-4138M | GD-4138H |
| Uburyo bw'ikizamini | Uburyo bwo kwerekana Arc, icyitegererezo cyubu, DC ibisohoka | Uburyo bwo kwerekana Arc, uburyo bwo kwerekana DC arc, icyitegererezo cyubu, ibisohoka DC | |
| Ubwoko bw'icyitegererezo cyerekana ibimenyetso | Uburyo bwinshi bwa pulse arc uburyo bwo kwerekana, ibyitegererezo byubu, voltage nkeya | Uburyo bwo kwerekana Arc, uburyo bwo kwerekana DC arc, icyitegererezo cyubu, ibisohoka DC | |
| DC HV ibisohoka | 0 ~ 16KV polarite mbi Ibisohoka ntarengwa: 152mA | 0 ~ 32KV polarite mbi Ibisohoka ntarengwa: 76mA | 0 ~ 8KV itari nziza polarite Ntarengwa isohoka: 304mA 0 ~ 16KVnegative polarite Ntarengwa isohoka: 152mA 0 ~ 32KVnegative polarite Ntarengwa isohoka: 76mA |
| Ubushobozi bwa Flashover | 0-16kV 8μF Ingufu ntarengwa zisohoka: 1024J | 0-32kV 4μF Ingufu ntarengwa zisohoka: 2048J | 0-8kV 32μF Ingufu ntarengwa zisohoka: 1024J 0-16kV 8μF Ingufu ntarengwa zisohoka: 1024J 0-32kV 4μF Ingufu ntarengwa zisohoka: 2048J |
| Gusohora icyuho cyikora | Intege nke zokugenzura solenoid valve icyuho cyikirere, igihe cyo gusohora kirashobora guhinduka kuva kumasegonda 3 kugeza 12, kandi muffler yagenewe byumwihariko kugirango ihuze ibisabwa na mute kugirango unanirwe insinga mugitangira. | ||
| Uburyo bwo gusohoka | DC ihangane na voltage, gusohora rimwe, gusohora buri gihe | ||
| DC ihangane na voltage | 16KV | 32KV | 32KV |
| Byemerewe kwinjiza impulse voltage | 16kV | 32kV | 32kV |
| Byemerewe kwinjiza imbaraga | <2048J | ||
| Ibidukikije | Ubushyuhe: 0 ~ 40 ℃ Ubushuhe bugereranije: <75% RH | ||
| Amashanyarazi | AC220V, 50Hz | ||
| Ubushobozi bwose | 3kVA | ||
Byakoreshejwe gupima intera intera.Muburyo bwa LV pulse, irashobora gukoreshwa wenyine.
7inch LCD ya ecran, intera yinshuti.
Uburyo butandukanye bwo gushakisha intera:
Uburyo buke bwa voltage pulse: burakwiriye gushakisha aho ikosa rito rirwanya, ikosa ryumuzunguruko mugufi, ikosa ryumuzunguruko.Irashobora kandi gukoreshwa mugupima uburebure bwa kabili, guhuza intera, guhuza T, hamwe no guhagarika umugozi.Ubu buryo kandi burashobora gukoreshwa mugukosora umuvuduko wumuraba.
Uburyo bwa pulse bugezweho: Birakwiriye gupima intera yikosa ryinshi ryo guhangana, amakosa yo gusenyuka.Ukoresheje coupler iriho kugirango ukusanye ibimenyetso kuva kwisi, bituma uyikoresha ari kure yumuriro mwinshi.Ubu buryo ni umutekano kandi bwizewe.
Impanuka nyinshi: inzira yambere yo gupima intera.Umuhengeri uroroshye kumenya kandi ukuri ni hejuru.
200MHz igihe nyacyo cyo gutoranya.Icyiza.0.4m yo gupima.Ifite agace gato kapfuye kandi ni umwihariko wa kabili ngufi kandi hafi ya kabili.
Kora kuri ecran hanyuma ukande ibikorwa byingenzi.Indanga irashobora gukururwa.
Kopi ya PIP (ifoto yo kubika by'agateganyo)
Hano hazaba idirishya nyamukuru hamwe nububiko butatu bwububiko bwigihe gito bushobora kugenzura imiterere itatu hamwe.
Yubatswe muri sisitemu y'imikorere
Imicungire idasanzwe ya software yo kuzamura software, kugarura no kugarura.
Igikorwa kinini
Ingingo imwe yo gutangiriraho, 10 ihuza, ikosa rimwe hamwe nuburebure bwuzuye bushobora gushyirwaho.
Erekana igipimo no kugerageza imiterere icyarimwe
Kubika Waveform no gutumanaho hamwe na mudasobwa.
Ububiko bwimbere bwimiterere.
Hamwe na USB, gukuramo cyangwa kohereza amakuru
Itumanaho na mudasobwa
Gucunga ingufu
Amatara yinyuma agabanuka niba ntagikorwa muri 2mins hanyuma amashanyarazi muri 10mins niba nta gikorwa.
Yubatswe muri bateri ya Polymer Lithium-ion.
Igihe cyo gukora ni amasaha 5 kuri buri koresha.
Urubanza rukomeye, byoroshye gutwara.
| Kubona uburyo | Uburyo buke bwa voltage impulse Hindura uburyo bugezweho Uburyo bwinshi bwo guhubuka |
| Icyiza.Guhitamo inshuro | 200MHz |
| Kwunguka | 0-70dB |
| Umuvuduko muke wa voltage impulse | 30V |
| Igisubizo | 0.4m |
| Icyiza.Urutonde | 100km |
| Agace kapfuye | 2m |
| Batteri | Nickel-metal hydride bateri zishobora kwishyurwa, igihe cyo kwihangana mumasaha 5 |
| Imigaragarire y'itumanaho | USB |
| Amashanyarazi | Injira AC220V, 50Hz, 2A y'ubu, yishyuza amasaha 8 |
| Dim. | 274 × 218 × 81mm |
| Ibiro | 3.5kg |
| Gukoresha Ubushyuhe | -10 ℃-40 ℃ |
| Ubushuhe | 5-90%RH |
| Uburebure | <4500m |
●Ibimenyetso bya Acoustic na magnetique byakirwa icyarimwe.Ubushobozi bukomeye bwo kurwanya kwivanga.
●Kwerekana.
●Acoustic magnetic waveform yerekana.
●Kumenya aho ikosa no gukurikira inzira.
●Hamwe na terefone kugirango wumve urusaku.
●320 * 240 LCD yerekanaImigaragarire.
●Yubatswe muri Li bateri, hamwe na charger yihuta.
●Irashobora kuzimya mu buryo bwikora niba idakora nyuma ya 15mins cyangwa bateri nkeya.
●Ingano nto, byoroshye gutwara.
●Umuyoboro wa signal ya Acoustic: hagati yumurongo wa 400Hz, umurongo wa 200Hz
●Inyungu y'ibimenyetso: 80db.
●Kumenya neza: 0.1m
●Amashanyarazi: yubatswe muri Li bateri, voltage nominal 7.4V, 3000mAh, gukomeza gukora 9hours.
●Amashanyarazi: Injiza AC220V ± 10%, 50Hz, ibisohoka nominal 8.4V, DC1A
●Igihe cyo kwishyuza: <amasaha 4
●Igipimo: 270 * 150 * 210mm.
●Uburemere: 1.5 kg.
●Koresha imiterere: ubushyuhe -10--40 ℃, ubuhehere 5-90% RH, ubutumburuke <4500m.