GD-875/877 Kamera yubushyuhe bwa kamera
Igenzura ryikora cyangwa intoki kugenzura ibipimo by'ubushyuhe
● ℃, ° F na K ibipimo byo gupima
● 11 ukoresha guhitamo palettes
● 9 ukoresha indimi zatoranijwe
Gupima ubushyuhe bushyushye
Gupima ubushyuhe bukonje
● Ibipimo 4 byimukanwa
Setting Ubushyuhe bwo hejuru bwo gushiraho
Kugaragaza - Kugaragaza indishyi z'ubushyuhe
X 2x zoom
Funga ecran kugirango urebe ishusho iriho
Out Gusohora amashusho - NTSC cyangwa PAL
Meas Gupima ubushyuhe mubice 3
● Imirongo 2 yo gupima ubushyuhe
Gukosora ubushyuhe bwimbere
Kubika ikarita ya TF
OS CMOS igaragara yumucyo nububiko
Gufata amajwi
Impuruza
Ection Gukosora ubushyuhe, gupima offset ikosora
Yubatswe muri Emissivity Imbonerahamwe yurutonde rwibikoresho bisanzwe
Ingingo | Parameter | |
Detector | Andika | Ubwoko budakonje bwindege ya micro-ubushyuhe bwubwoko |
Pixel | 160 * 120 | |
Ikibanza cya Pixel | 25 mm | |
Urwego rw'uburebure | 8-14 mm | |
Guhitamo inshuro | 50Hz | |
Ubushyuhe bukabije | 0.06℃@ 30 ℃ | |
Lens | Umwanya wo kureba | 25°* 19° |
Intera yegereye ikintu | 10cm | |
Uburyo bwo kwibanda | Intoki | |
Lens yaguye | 0.5x / 2x, ntibishoboka | |
Ubwoko bw'imbere | Bayonet | |
Imikorere y'amashusho | Gukemura ahantu | 2.72mrad |
Gukoresha ibikoresho bya elegitoroniki | 2X | |
Kamera yumucyo igaragara | Module ya CMOS | |
Igipimo cyamakadiri | 50 / 60Hz, birashoboka | |
Ibisohoka | PAL / NTSC, birashoboka | |
Kwerekana amashusho | Mugaragaza LCD | 3.5 ″ TFT LCD,320 * 240,amabara |
Ibara palette | Amabara 11 palette kugirango uhitemo | |
Guhindura amashusho | Imodoka / intoki guhinduranya itandukaniro no kumurika | |
Kwerekana amashusho | Hindura vuba hagati ya infragre kandi igaragara | |
Gutunganya amashusho | mu buryo bwikora / intoki | |
Igipimo | Urwego rw'ubushyuhe | -20℃~ + 350℃ |
Ubushyuhe | ±2℃or ±2% gusoma, fata agaciro kanini | |
Gukosora ubushyuhe | Imodoka (igihe gito, umwanya muremure, igihe cyihariye) / imfashanyigisho | |
Uburyo bwo gupima | Ingingo zimuka (kugeza kumanota 4), ahantu hashobora kwimuka (kugeza ahantu 3, gupima impuzandengo yubushyuhe bwo guhitamo, ntarengwa / ntarengwa yubushyuhe bwo gukurikirana), imirongo yimukanwa (kugeza kumurongo 2), ecran yuzuye ntarengwa / ikurikiranwa ryubushyuhe, kwerekana kugeza kuri 5 amatsinda Data;isesengura rya isothermal, isesengura ryubushyuhe, gukurikirana ubushyuhe, impuruza yubushyuhe (ijwi, ibara) | |
Gukosora Emissivity | Guhindura kuva 0.01 kugeza 1.0 (mubyiyongereyeho 0.01) cyangwa hitamo kurutonde rwibikoresho byateganijwe mbere | |
Gukosora ubushyuhe bwimbere | byikora | |
Ikosora rya Atmospheric | Automatic, ishingiye ku ntera yinjiye, ubushuhe bwibidukikije hamwe nubushyuhe bwibidukikije | |
Gushiraho imikorere | Itariki / isaha, ubushyuhe buke ℃ / ℉ / K, ururimi | |
Kubika amashusho | ikarita yo kubika | 8GB Ikarita ya Micro TF, inkunga igera kuri 16GB |
Ubwoko bwububiko | Ububiko bw'intoki / bwikora;ishusho imwe ya infragre ishusho, infragre kandi igaragara yumucyo bijyanye nishusho | |
Imiterere yishusho yubushyuhe | Imiterere ya JPEG hamwe namakuru yimibare yo gupima | |
Imiterere yumucyo igaragara | Imiterere ya JPEG | |
Inyandiko | Amasegonda 60 (uzigame nishusho) | |
Amashanyarazi | Batteri | Bateri ya lithium yumuriro, irashobora gusimburwa |
Igihe cyo gukora | Gukomeza gukora amasaha arenga 4 | |
Uburyo bwo kwishyuza | Amashanyarazi yubusa cyangwa kwishyuza bidasanzwe (AC power adapter cyangwa amashanyarazi ya 12V) | |
Igihe cyo kwishyuza | Kwishyuza bisanzwe mumasaha 1.5 arenze ubushobozi bwa 50% | |
Uburyo bwo kuzigama ingufu | Kwisinzira byikora, guhagarika byikora | |
Imigaragarire | Ikarita yo kwibuka | Micro SD (ikarita ya TF) |
USB Imigaragarire | Nibyo, ihererekanyamakuru | |
Imigaragarire y'amashanyarazi | Yego (DC 12V) | |
Imigaragarire ya videwo | Yego | |
Abandi | Microphone | Yubatswe |
Buzzer | Yubatswe | |
Umwanya wa Laser | Umutuku, 1mw / 635nm, icyiciro cya 2, IEC60285 | |
Urudodo | 1/4 ″ -20-UNC | |
Handrail | Irashobora gushyirwaho kumpande zombi | |
lens cap | Yego | |
Izuba Rirashe | Yego, birashoboka | |
Ibidukikije | Ubushyuhe bwo gukora | -15℃~ + 50℃ |
Ubushyuhe bwo kubika | -40℃~ + 70℃ | |
Ubushuhe | ≤95% bidacuramye | |
Icyiciro cyo kurinda | IP54 | |
Ingaruka zo kurwanya | 25G, IEC68-2-29 | |
Kurwanya kunyeganyega | 2G, IEC68-2-6 | |
Kugwa | 2 metero | |
Umubiri Ikiranga | Igipimo | 105 * 230 * 245 mm |
Ibiro | 980g |