GDBT-8610P Ikizamini cya Batteri
Ikizamini cya Batiri GDBT-8610P gikoreshwa cyane mubice bikurikira:
● Itumanaho: Ibiro bikuru, ibigo bitunganya amakuru hamwe na site ya kure
Ut Gukoresha ingufu: Guhindura amashanyarazi, Sitasiyo yamashanyarazi
Institution Ibigo by'imari: Ibigo bishinzwe amakuru
● Ibikomoka kuri peteroli: Sisitemu yo kugenzura inzira
Platforms Offshore platform
● Guverinoma: Inzego z'ibanze n'akarere
● Ibigo bitunganya imisoro n'amahoro
Security Umutekano mu Gihugu, Amashuri, Ingabo na Navy
Facilities Ibikoresho byo mu kirere, Ibiro bishinzwe kuzimya umuriro na polisi
System Sisitemu ya UPS
Abatanga ibinyabiziga by'amashanyarazi
Battery SATERI ikora
Range Ikizamini kinini: 5 ~ 6000Ah, gihuza selile imwe ya 1.2V, 2V, 6V na 12V
Device Igikoresho cyubwenge kandi kigendanwa gifashwe nintoki, cyoroshye kandi cyoroshye-kugenda
Screen Gukoraho amabara meza hamwe nibikorwa bidahwitse bya clavier
Gerageza icyarimwe kugerageza voltage, kurwanya no kugereranya ubushobozi bwa bateri
Meas Ibipimo byo kumurongo, ntabwo bikenewe gukuraho bateri numugozi muri sisitemu yo kugerageza, umutekano kandi byoroshye
Testing Kwipimisha byihuse kuri bateri numugozi mumasegonda hamwe no kugerageza amakuru kubika imodoka
Kurwanya-kwivanga gukomeye mugihe kinini hamwe nibikorwa bihamye kandi neza
Kwipimisha inshuro ziri munsi ya Hz 10, irinde rwose kwivanga mubushobozi bwa bateri ubwayo
Drive Direct USB ya disiki yo kuvugurura software no kohereza amakuru kuri PC kugirango irusheho gusesengura
Software Porogaramu ikomeye yo gucunga PC, yorohereza kubika amakuru no gusesengura
Memory Ububiko bunini bwo kugerageza kubika amakuru arenga 3000 selile
Fun Buzzer Alarm Imikorere no hejuru ya voltage kurinda, umutekano wo gukoresha
● Auto-calibration imikorere mbere yo kwipimisha, kuzamura ibizamini byukuri
Igikorwa cyo gusubiramo no kwishyura indishyi: imikorere iyo ari yo yose cyangwa ikosa rishobora gusubirwamo ukanze rimwe
Data Ibyerekanwe imbere mububiko bwo kugereranya ikizamini cyawe, kandi indangagaciro zisobanutse zirahari
Urwego rwo kurwanya | 0.00mΩ ~ 100mΩ | Umuvuduko w'amashanyarazi | 0.000V ~ 16V * |
Gukemura ikibazo gito-umuvuduko -kurwanya
| 1mv 0-999μΩ: 1 μΩ 1-9mΩ: 10μΩ (0.01mΩ) 10-99mΩ: 100 μΩ (0.1mΩ) | Ikizamini -voltage -kurwanya
| ± 0.2% rdg ± 6dgt 0μΩ-250μΩ: 8% ± 6DGT 250μΩ-500μΩ: 3% ± 6DGT 500μΩ-100mΩ: 1% ± 6DGT |
Amashanyarazi | 7.2V 2400mAhBateri ya Li-ion | Igihe cyo gukora | Amasaha arenga 5 nyuma yo kwishyurwa byuzuye |
Gupima ububiko bwamakuru | Ingirabuzimafatizo 3000 | Ibidukikije | 0 ℃ kugeza 40 ℃90% RH |
LCD yerekana | 320 * 240 pigiseli TFT ikoraho | Igipimo(igice nyamukuru) | L210 * W110 * H60 mm |
Uburemere bwiza(paki) | 2 kg | Icyambu | Mini USB |