GDOH-II Yipimisha Ibikomoka kuri peteroli
GDOH-II Igerageza Ibikomoka kuri peteroli Ibizamini ni igisekuru gishya cyipimisha gikoresha ibyuma bitumizwa mu mahanga hamwe n’ikoranabuhanga rishya rya sensor.Ishingiye kuri DL423-91 yinganda zinganda ninganda zigihugu.Nibikorwa bifatika, bihamye kandi byizewe mubikorwa, biroroshye gukora kandi birakwiriye kugena ibirimo gaze mubikoresho byuzuye amavuta ya ultra-high voltage.Nibikoresho byiza byo gupima laboratoire.
●Imiterere y'ibyuma byose birinda ibibazo byo gucika intege no gufunga nabi kwipimisha ibirahure.
●Ikoreshwa ryibisobanuro bihanitse kandi bihamye bitumizwa mu mahanga bitandukanya igitutu cyerekana amakuru yikizamini neza kandi gisubirwamo.
●Umuzenguruko wikizamini urimo sensor zipima umuvuduko wikirere nubushyuhe bwibidukikije.Aho waba uri hose, urashobora guhita upima ubushyuhe bwibidukikije hamwe n’umuvuduko w’ikirere aho uherereye, uhita uhindura gaze kuri 0 ° munsi yumuvuduko usanzwe w’ikirere, hanyuma ukabigaragaza neza kuri ecran ya LCD
●Porogaramu idasanzwe yo gutera gazi irwanya ibizamini igufasha kugenzura byoroshye niba igikoresho cyahinduwe cyangwa gipimwa neza.
●Amavuta yintangarugero yo kugerageza ni mugufi, kandi igihe cyose cyo kugerageza gifata iminota 7 gusa.
●Mugihe cyikizamini, imikorere ya pompe vacuum igenzurwa nigikoresho ukurikije leta, igabanya cyane urusaku kandi ikongerera igihe cyakazi cya pompe vacuum.
●Igikoresho gishobora guhita kibika amakuru yanyuma yikizamini, kandi ikabika igihe cyikizamini, ubushyuhe, umuvuduko wikirere, nibindi, kugirango ubashe kugenzura byoroshye amakuru.
●Hamwe nimikorere yo gucapa, urashobora gucapa amakuru yikizamini ukurikije ibyo usabwa.
●Urugero rumwe rwamavuta rushobora gutoranywa kumubare wibizamini.Ikizamini kimaze kurangira, ibisubizo hamwe nibisubizo bizerekanwa kumurongo cyangwa byacapwe.
Icyuma-cyinshi cya elegitoroniki itandukanya igitutu sensor | Icyemezo ntabwo kiri munsi ya 0.1%. | |
Ntarengwa ntarengwa | Ntabwo arenga 0.2%. | |
Ukuri | Ikosa rigereranijwe ryibisubizo byapimwe ntibigomba kurenza indangagaciro zikurikira: | |
Ibirimo gaze mumavuta (agace k'ubunini),% | Ikosa rifitanye isano,% | |
<0.5 | 10 | |
0.5 ~ 1.0 | 8 | |
1.0 ~ 3.0 | 5 | |
> 3.0 | 3 | |
Gutesha agaciro icyumba cyo kugenzura ubushyuhe | 5 ℃ kugeza 70 ℃ hejuru yubushyuhe bwicyumba | |
Amashanyarazi akora | AC 220V ± 10%, 50Hz | |
Igipimo | 450 * 325 * 350 mm | |
Ibiro | Hafi 20kg |
Ikizamini | 1 set |
Umugozi w'amashanyarazi | Igice 1 |
Vacuum pump & umuhuza | 1 set |
3mm umuyoboro w'icyuma | 1.5m, 0.5m |
Umuhuza wa syringe | 1 set |
Fuse 10A | Ibice 3 |
M8 × 1 nut | Ibice 10 |
Ikirango | Ibice 10 |
Siringe bracket | Igice 1 |
1mL ya kalibrasi ya syringe | Igice 1 |
Rotary vane vacuum pompe | 1 set |
Igitabo gikubiyemo amabwiriza | Kopi 1 |
Icyemezo cyibicuruzwa | Kopi 1 |
Raporo y'ibizamini by'uruganda | Kopi 1 |
Urutonde | Kopi 1 |