GMDL-02A HV Umuzenguruko Wumuzenguruko
GMDL-02A igikoresho cyigana amashanyarazi menshi yumuriro wigikoresho cyakozwe hifashishijwe amahame yimirima minini yumurima ushobora gutegurwa amarembo, ibikoresho bya elegitoroniki hamwe nuburinzi, nibindi.
Igiceri gifunguye cyateguwe ukurikije icyerekezo cyigenga, gishobora kwigana ibyiciro bitatu no kugabana-ibice byimikorere ya voltage ya 6-110KV.Imyitwarire yibikorwa bya firime imwe ifunguye yamashanyarazi ikwiranye no gutoranya amashanyarazi, inganda n’inganda zicukura amabuye y'agaciro, ibigo byubushakashatsi bwa siyansi, amashuri makuru y’umwuga, n’abakora ibicuruzwa birinda.
Ikoreshwa nkigisimbuza ibyuma byumuzunguruko nyirizina mugupimisha ikwirakwizwa rya sisitemu yose yo kurinda relay hamwe nibikoresho byikora hamwe na switch.
Igikorwa nukuri, cyizewe, kandi umubare wibikorwa ntabwo ugarukira, ushobora kunoza cyane ukuri kwuzuye no kuzuza ikizamini, kugabanya umubare wibikorwa byumucyo nyirizina, no kongera ubuzima bwa serivisi.Nibikoresho byingenzi byunganira ibikorwa byo kurinda relay.
Amashanyarazi akora amashanyarazi: | AC220V ± 10% 50HZ ikora ikora iri munsi ya 0.5A | |
fungura no gufunga voltage ikora: | DC200V cyangwa DC110V. | |
gufungura no gufunga igihe | gufungura igihe cyo guhitamo: | Gusoza igihe cyo guhitamo: |
20ms, 30ms, 40 ms, 50 ms, ms 60, ms 70, 90 ms, 110 ms, ikosa ntirirenga ± 5ms | 40 ms, 60 ms, 80 ms, 100 ms, 200 ms, 300 ms, 400 ms, 500 ms, ikosa ntirenza ms 5ms, (iyo 500m, ikosa ntirenza m 20ms). |
fungura no gufunga ikigezweho | fungura abarwanya guhitamo: | ∞Ω, 100Ω, 200Ω, 400Ω |
Gufunga guhitamo kurwanya: | ∞Ω, 100Ω, 200Ω, 400Ω | |
Gufungura no gufunga umuyaga uhita ucibwa mugihe cyo gufungura no gufunga. | ||
Gufungura intoki no gufunga | Iyo igikoresho cyo kwigana amashanyarazi menshi yumuriro gikoreshwa binyuze muri "manual close" na "manual open" buto kuri panel, igikoresho cyo kwigana amashanyarazi y’umuvuduko mwinshi kirakingurwa, kandi ntagitemba kiri muri coil yo gufunga. | |
Kunanirwa kumena | Iyo bouton yamashanyarazi yamashanyarazi ikanda, icyuma cyumuzunguruko ntigikora, imiyoboro yo gufungura no gufunga itinda nyuma ya 1s hanyuma igacibwa, hanyuma leta igasubirana nyuma yindi 20. | |
Shushanya | Shushanya: | |
DC220V / 0.5A, AC220V / 5A. | ||
Umuzenguruko wumuzingi wumwanya wo gusohoka: | Ibice 12 byumuzunguruko wumwanya wo gusohora ibisohoka, bitigenga.Igabanyijemo amatsinda abiri, ahuye na break break yamashanyarazi. | |
Gufunga ukuboko, gusimbuka intoki: | Intoki-gufunga no gusimbuka intoki buriwese afite ihuriro ryibisohoka mubisanzwe bifungura imibonano.Iyo ukuboko gufunga no gusimbuka amaboko buto, guhuza birahuza.Muri byo, gufunga intoki kwifata ubwabyo nyuma yigikorwa, no gusubiramo ukoresheje buto yo gusimbuka.Iyo buto yo gusimbuka intoki irekuwe, guhuza intoki bizagaruka hamwe no gutinda kwa 60m. |