HV-OWS-63 Sisitemu yo Kwipimisha Umuhengeri (OWTS) kurubuga PD Gusuzuma insinga
1. Urukurikirane rwa HV-OWS ni sisitemu yo gupima igice cyo gusohora igice, ikoreshwa cyane mugusuzuma igice cyo gusohora igice cyinsinga ziciriritse.Sisitemu yikizamini cya sisitemu ni 50Hz kugeza kuri magana ya Hz ya damping ya AC yamashanyarazi, voltage ya AC itangwa na sisitemu mugihe cyibizamini irashobora kugera kuri 60kV, kandi igahuzwa nibikoresho bigezweho bya sisitemu hamwe na software ya sisitemu yo gusuzuma.
Technology Ikoranabuhanga rigezweho rya elegitoroniki ya semiconductor
Technology Ubuhanga bugezweho bwo kugenzura laser
● Iterambere ryibikoresho bya digitale hamwe nubuhanga bwo kuyungurura
Technology Ikoranabuhanga rigezweho ryo kugenzura imiyoboro.
2. Porogaramu yo gupima no gusesengura irashobora gukora isesengura ryamakuru ya kure ukurikije imiterere y'urusobe.
3. Imigaragarire yuzuye yicyongereza, ishoboye gufata amajwi ya oscillating voltage yumurongo hamwe nigice cyo gusohora ibimenyetso byerekana igice, no gukora utudomo-nyabwo mugihe cyo gukanda;
4. Kwerekana mu buryo bwikora inshuro, amplitude hamwe nicyitegererezo cyigihe cyubugari bwumubyigano wa voltage.
5. Irashobora guhita isesengura kwaguka kwimiterere yikimenyetso cyageragejwe igice.
6. Kwerekana mu buryo bwikora agaciro ka test ya dielectric.
7. Mu buryo bwikora gukora ikarita yerekana aho igice gisohokera kandi ikabyara raporo y'ibarurishamibare, hanyuma igahita itanga ikarita y'ibarurishamibare igice.
Umuvuduko w'amashanyarazi | Ntarengwa: ± 60kVimpinga |
Umwanya wa Oscillation | 20Hz ~ 850Hz |
Inductance | 1.0H ~ 2.1H (bidashoboka) |
Isesengura ryamakuru | Isesengura ry'intoki, isesengura ryikora (igereranya na sisitemu yo kuyungurura) |
Ubushobozi bugomba gupimwa | 0.05 ~ 5uF |
Umuyagankuba mwinshi | 10mA |
Ikizamini cyo gusohora igice | 10pC ~ 200nC |
Ibipimo bifatika | ± 0.1pC (icyitegererezo 14bits) |
Umuvuduko mwinshi | 50-300m / us |
Kubona neza | ± 0.1m |
Kubona ikosa | ≤1% × uburebure bwa kabili |
Kugaragaza urwego rwa PD | Ukurikije IEC60270 |
PD gushakisha umurongo | 100kHZ ~ 50MHZ guhitamo cyangwa guhitamo intoki |
Igihombo cya dielectric tan tan δ | 0.1% ~ 10% |
Tanga voltage | 180V ~ 250V, AC 50Hz |
Ubushyuhe bwo gukora | -120 ℃ ~ + 60 ℃ |
Ibiro | Ibiro 88 |
Ingano | Diameter 650mm, uburebure bwa 980mm |
Imigaragarire | WLAN (IEEE802.11g) / 100M Ikarita ya Ethernet |
Oya. | Izina | Qty. |
1 | HV-OWS-63 ihindagurika ryikizamini cya sisitemu nyamukuru | 1set |
2 | Mudasobwa ya ikaye (hamwe na sisitemu yubatswe yizunguruka igice cyo gusohora no gusesengura software) | 1set |
3 | Ubushobozi bwo kwishyura hanze | 1set |
4 | Umuyoboro mwinshi wa voltage pulse | 1set |
5 | Umugozi wikizamini cyo hejuru | 1set |
6 | Umuyoboro mwinshi uhuza umugozi (uhuza ubushobozi bwindishyi) | 1set |
7 | Calibration pulse generator ya kabili (umutuku umwe numukara umwe) | 2pc |
8 | Kugenzura umugozi wo kugura | 1pc |
9 | Umuyoboro w'itumanaho (hamwe numuyoboro wubwoko-c module) | 1pc |
10 | Umugozi wubutaka | 1pc |
11 | Inkoni y'ubutaka | 1pc |
12 | Umugozi w'amashanyarazi | 1pc |
13 | Ibikoresho by'insinga | 1pc |
14 | Imfashanyigisho | 1copy |
15 | Icyemezo / Ikarita ya garanti | 1copy |
16 | Urutonde | 1copy |