●Imikorere yuzuye kandi irashobora guhaza ubwoko bwose bwa CT (kurinda CT, gupima CT, TP) ibisabwa byikizamini, nkibizamini biranga umunezero, igipimo cyo guhinduka, polarite, icyiciro cya kabiri cyumuyaga, umutwaro wa kabiri, ikosa ryikigereranyo, itandukaniro ryinguni nibindi nibindi birashobora kandi gukoreshwa kugerageza kwishima biranga, guhinduka, kugereranya, polarite, irwanya iringaniza, ikosa ryikigereranyo, itandukaniro ryinguni nibindi byubwoko bwose bwa PT.
●Kugenzura umurima wa CT ntibisaba guhinduranya ibintu bisanzwe, inshinge zubu, banki yimizigo, voltage igenzura umugenzuzi ninsinga nini zubu.Ikigereranyo cyoroshye cyane cyogukoresha nigikorwa bikoreshwa kugirango tumenye verisiyo igezweho, igabanya cyane imbaraga zakazi kandi igatezimbere imikorere, kandi ikorohereza kugenzura umurima.
●Gupima neza ikosa ryikigereranyo no gutandukanya inguni, ikosa ntarengwa ryemewe ryikosa ryikigereranyo ni ± 0,05%, naho ikosa ntarengwa ryemewe ryitandukaniro ni ± 2min.Irashobora gupima urwego 0.2S urwego ruhindura, kandi igipimo cyo gupima ni 1 ~ 40000.
●Ukurikije uburyo bugezweho bwo guhindura uburyo bwo kugerageza CT / PT voltage-igezweho iranga umurongo hamwe na 10% ikosa ryikosa, ntarengwa ya voltage ya AC ya 180V na AC ya 12Arms (impinga ya 36A) irashobora gusohoka, ariko irashobora guhangana nikizamini cya CT y'ivi kugeza kuri 60KV.
●Ikizamini cyimodoka CT / PT ibipimo nka ivi point voltage / ikigezweho, 5% na 10% ikosa ryikosa, ntarengwa ntarengwa (ALF), ibintu byumutekano (FS), umwanya wigihe cya kabiri (Ts), coefficient ya magnetiki remanence (Kr), yuzuye na inductance idahagije.
●Ikizamini cyujuje ubwoko butandukanye bwa transformateur nka GB1208 (IEC60044-1), GB16847 (IEC60044-6), na GB1207, kandi ibipimo by ibizamini bihita bitoranywa ukurikije ubwoko nurwego rwa transformateur.
●Ikizamini kiroroshye kandi cyoroshye.Kurwanya CT DC, kwishima, kugereranya na polarite birashobora kurangizwa nurufunguzo rumwe.Usibye ikizamini cyumutwaro, ibindi bizamini byose bya CT bifata uburyo bumwe.
●5.7-santimetero ishushanya LCD, igaragara neza ku zuba.
●Ikoreshwa nimbeba ya optique izenguruka, imikorere iroroshye, byihuse kandi byoroshye, kandi byoroshye kuyobora.
●Mucapyi yubatswe, ihita icapa raporo yakozwe.
●Ibisubizo byikizamini birashobora koherezwa hanze na U disiki, kandi porogaramu irashobora kuzamurwa na U disiki, byoroshye kandi byihuse.
●Bika amatsinda 1000 yamakuru kandi ntabwo yatakaye nyuma yamashanyarazi.
●Ifite ibikoresho byo gusesengura inyuma kugirango byoroherezwe kubika, guhindura no gusesengura raporo y'ibizamini, kandi birashobora gukoreshwa mu kugereranya, guca imanza no gusuzuma amakuru y'ibizamini.
●Biroroshye gutwara, uburemere bwibikoresho <10kg.