GDHX-9500 Ikimenyetso Cyicyiciro
GDHX-9500 Icyiciro cya Detector ikoreshwa cyane cyane mumirongo yumuriro wamashanyarazi, icyiciro nicyiciro cya kalibrasi ya kalibrasi mugusimbuza, hamwe nibikorwa byingenzi birimo kugenzura amashanyarazi, kalibrasi yicyiciro no gupima icyiciro.Ikoresha uburyo bubiri bwo gukingira no gushiraho imiyoboro mishya ya digitale, hamwe no kurwanya-kwivanga gukomeye, ijyanye n’ibipimo bya EMC, ikwiranye n’ibihe bitandukanye byo guhuza amashanyarazi.
Ikimenyetso cyinshi cya voltage yicyerekezo cyapimwe kizoherezwa nyuma yubuvuzi, terefone yakira kandi igereranya icyiciro, igena ibisubizo nyuma yo gutahura icyiciro, igihe nyacyo cyo kwerekana icyiciro cyerekana itandukaniro na vector.Bikoresha tekinoroji yohereza itagikoreshwa, umutekano kandi wizewe , byihuse kandi byukuri, bikwiriye gukoreshwa kurwego rwa voltage zitandukanye (6V-500KV).Iyo ugenzuye imiterere ya gride, irashobora kumenya neza icyiciro kigereranyo cyibice bitandukanye biganisha kumurongo wibyiciro bitatu bihujwe, nta guhuza amashanyarazi hagati yibice bibiri byo gupima, bigatuma ikoreshwa ryibikoresho bipima byoroshye kandi bifite umutekano.
●Ukoresheje tekinoroji yohereza itagikoreshwa, ihame ryibanze ryakazi ni igihe nyacyo cyo kugereranya.
●Nyamuneka reba kandi ukurikize amabwiriza yo gukoresha iki gicuruzwa, kugirango umenye neza imikorere yigikoresho, impera za X na Y deteter ntizemewe gukora ikizamini cya voltage.
●Ibice byumutwe wicyuma cyikingira birabujijwe rwose guhura nibintu byose mugihe cyizamini.
●Nyamuneka kurikiza amabwiriza yigihugu yinganda zumutekano zumutekano wikizamini cyo gukumira ibikoresho nibicuruzwa.
●Nyamuneka nyamuneka witondere amahugurwa nibizamini kubakozi bakora kumurongo wa voltage mwinshi cyangwa hafi yumurongo wa voltage.
●Icyiciro cya kalibrasi kubikoresho bizima bigomba gukorwa no gukingira inkoni.
Icyitonderwa: Uburebure bukoreshwa neza hamwe nibipimo byo gupima inkoni ya "Wireless Phase Detector".
.
1. Intera yumutekano hagati y abakozi nu mubiri wishyuzwa mugihe gikora.
Urwego rwa voltage | 10kV | 35kV | 66kV | 110kV | 220kV | 330kV | 500kV |
Intera yumutekano | 0.4M | 0.6M | 0.7M | 1.0M | 1.8M | 2.2M | 3.4M |
2. Uburebure ntarengwa bwo gukingira inkoni mugihe gikora.
Urwego rwa voltage | 10kV | 35kV | 66kV | 110kV | 220kV | 330kV | 500kV |
Min.uburebure bukomeye | 0.7M | 0.9M | 1.0M | 1.3M | 2.1M | 3.1M | 4.0M |
Icyitonderwa: Ikizamini cyibikoresho byo kugenzura ibikoresho byo kugenzura (agace): gukoresha ingufu za 75kV buri 300mm kuri 1min, niba nta gusenyuka, nta flashover nubushyuhe burenze, bifatwa nkibisabwa.
●Umuvuduko wikizamini: 10V-500kV, ubereye urwego rutandukanye rwa voltage.
●Ukuri: kwibeshya-kwibeshya ≤ ± 3 °.
●Umuvuduko w'icyitegererezo: inshuro 10 / s.
●Itariki nigihe cyagenwe: itariki nigihe cyo guhindura, byoroshye kubakoresha gushakisha, kureba amakuru yamateka.
●Igenamigambi ryinyuma-yumucyo: mubisanzwe kuri, mubisanzwe kuzimya, 0-999s irashobora gushyirwaho numukoresha.
●Imashanyarazi yimodoka izimya: 0-999mins irashobora gushyirwaho numukoresha.
●Mu cyiciro: ≤20 ° ifatwa nkicyiciro (icyiciro cya mbere muri 0-90 °, gishobora gushyirwaho nabakoresha. Sisitemu isanzwe ni 20 °.)
●Icyiciro cyujuje ubuziranenge:> 20 ° (icyiciro cya mbere muri 0-90 °, gishobora gushyirwaho numukoresha. Sisitemu isanzwe ni 20 °.)
●Imikorere ya kalibrasi yumurima: kurubuga rwa kalibrasi kubipimisho byapimwe, menya neza niba impande zingana.
●Intera yoherejwe hagati ya terefone na X, Y detector: X≤150m, Y≤150m.
●Igishushanyo cyuburyo bwinshi, hamwe nibisabwa bikomeye, umutekano kandi byoroshye.
●Imigaragarire idasanzwe ya mudasobwa na mudasobwa, imikorere yoroshye.
●Igishushanyo cya antenna ya FCC, ikimenyetso kirakomeye kandi cyoroshye kwinjira mukuzitira urukuta, umuryango, cyangwa bariyeri.
●Gukingira kabiri, gukomera an-ti kwivanga, byuzuye bijyanye na EMC.
●Imbonerahamwe namakuru yerekana, byoroshye kandi byoroshye gusoma.
●Ibipimo byujuje ubuziranenge, byerekanwe n'amajwi n'amatara.
●Ibipimo byuzuye, igihe-cyerekana icyiciro cyerekana itandukaniro, ikosa≤5 °.
●Icyiciro gikurikirana kalibrasi, icyiciro cyiza gikurikiranye, icyiciro kibi (120 °, 240 °).
Ikizamini cya voltage | 10V-500kV |
Amashanyarazi | Intoki: No.5 AA bateri ya alkaline ibice 2 (1.5V) |
Ikimenyetso cya X na Y: No.7 AA bateri ya alkaline ibice 2 (1.5V) | |
Intera yoherejwe | Intera igaragara 150m |
Mu cyiciro | Icyiciro cyo gutandukana ≤20 ° (imbago muri 0-90 °, irashobora gushyirwaho nabakoresha ubwabo.) |
Icyiciro | Icyiciro cyo gutandukana> 20 ° (imbago muri 0-90 °, irashobora gushyirwaho nabakoresha ubwabo.) |
Erekana ukuri | Ibipimo byuzuye≤3 ° |
Icyiciro cyo gukemura | 1 ° |
Ibipimo bikurikirana | Binyuze kuri 120 ° isaha / 240 ° irwanya isaha kugirango umenye kandi werekane icyiciro gikurikirana |
Erekana | Kugaragaza neza LCD, kwerekana neza munsi yizuba |
Ubushyuhe bwo gukora | -35 ℃ - + 50 ℃ |
Ubushyuhe bwo kubika | -40 ℃ - + 55 ℃ |
Ubushuhe bugereranije | ≤95%RH, Ntibisanzwe |
Handset | 0.31kg |
Ikimenyetso cya X. | 0.13kg |
Y detector | 0.13kg |