GDYZ-301 Ikizamini cya Zinc Oxide
1. 800 * 480 ibara rya LCD ikoraho, hamwe nicapiro ryihuta ryumuriro.
2. Igishushanyo cyerekana, Imigaragarire yimbere, byoroshye gukora no gukoresha kurubuga.
3. Intera ndende yoherejwe.PT ibimenyetso simusiga intera irenga 400m (2000m irashobora gutegurwa).
4. Birakwiriye kwipimisha mubihe bitandukanye nko gufata inkuba hamwe cyangwa amashanyarazi, laboratoire.
5. Gerageza ibyiciro bitatu byubu, voltage yicyiciro kimwe icyarimwe, ikora neza.
6. Nta mashanyarazi akomeye imbere, voltage itarenze 12V.Ibyuma bya voltage na voltage byitaruye rwose, bifite umutekano kandi byizewe.
7. Shyigikira icyitegererezo cya voltage zitandukanye: 1. Wired;2 simsiz;3. Ntabwo ari voltage;
A. Umugozi: guhererekanya ibimenyetso bya digitale hamwe na kabili ibimenyetso biva muri PT metering winding;
B. Wireless: ibimenyetso bya digitale itumanaho bidasubirwaho icyo kimenyetso kiva muri PT metering winding;
C. Ntabwo ari voltage: nta mpamvu yo kubona ibimenyetso biva muri PT.Koresha kubara software kugirango ubone voltage isanzwe.
8. Yubatswe mubushobozi buhanitse Li-bateri, ibereye ntamashanyarazi.
9. Yemera ibyuma byinjizwamo ibyuma hamwe na sisitemu y'imikorere yashyizwemo, irashobora kwagura ibikorwa byo gukina amajwi n'amashusho n'imikorere y'imyidagaduro.
10. Igikoresho kirashobora gufungura no kuzimya igihe icyo aricyo cyose, kikaba gihamye kuruta igikoresho gifite mudasobwa yinganda nkibikoresho byibyuma, kandi ntibyoroshye guhanuka no gusenyuka kwa sisitemu.
11. Bifite icyambu cya USB kugirango ushyigikire kohereza amakuru muri disiki ya U.
12. Yubatswe muri 4GB SD SD, irashobora kubika amakuru manini yikizamini, kandi ifite imirimo nko gucunga amakuru no kubika.
13. Umuvuduko mwinshi wo gutoranya inshuro nyinshi, tekinoroji yambere yo gutunganya ibimenyetso bya digitale, imikorere ikomeye yo kurwanya interineti, ibisubizo byo gupima neza.
14. Hamwe n'umukungugu, utarinze amazi, udukingirizo twa plastike turwanya ruswa, ubunini buto, uburemere bworoshye, byoroshye gutwara.
1. Amashanyarazi
Shigikira amashanyarazi yo hanze (12V / 2A) nuburyo bwo gutanga amashanyarazi imbere;
Urwego rwo gupima
Ibimeneka bigezweho (RMS) 0-10mA (byapimwe);
Umuvuduko (RMS) 30-100V (nini).
3. Gupima ukuri
Ibiriho: byose hamwe> 100μA, ± 2% yo gusoma ± 1digit;
Umuvuduko: Ikimenyetso cya voltage yerekana> 30V
Wired: ± 2% yo gusoma ± 1digit;
Wireless: ± 5% yo gusoma ± 1digit;
4. Ibipimo byo gupima
Kumeneka kwimyuka yose igezweho, ibyingenzi shingiro RMS, agaciro keza.
Ibintu birwanya ibice byingenzi RMS yamenetse, inshuro 3, 5, 7 RMS.
Ibintu birwanya impinga yibiciro byamazi yamenetse, harimo agaciro keza cyane Ir +, agaciro keza cyane Ir-.
Umuyoboro wibanze wibanze, voltage yuzuye, ibyiciro byuzuye bitandukanijwe.
Umuvuduko RMS.
Gukoresha ingufu z'abafata.
5. Reba uburyo bwa voltage ibimenyetso byerekana uburyo
Guhuza insinga: 20m (irashobora kwagurwa);
Guhuza Wireless:> 400m (irashobora kwagurwa);
6. Ibikoresho bya Batiri
Igihe cyo kwishyuza> amasaha 6
Gukomeza akazi> amasaha 4
Igihe cyakazi cyo gukora> amasaha 8
7. Igipimo:360 * 260 * 140mm (Abashitsi);420 * 330 * 200mm (Urubanza);
8. Uburemere:5kg (Abashitsi);9kg (Urubanza);
Igishushanyo 1 Ikibaho
1. Icyambu cyo hasi 2. 0-2mA ibyinjira byubu 3. 2-10mA ibyinjira byubu
4. Antenna yonsa 5. Icyambu cya syncronisation port 6. Icyambu cya syncronisation
7. ON / OFF buto 8. Kwishyuza icyambu 9. Ikimenyetso
10. Ikimenyetso cyimbaraga 11. Umufana 12. Interineti ya USB 13. Gukoraho ibara LCD ecran 14.Icapiro
Igishushanyo 2 PT Umuyoboro w'amashanyarazi
1. ON / OFF buto 2. Icyambu cyo kwishyuza 3. Ikimenyetso cyingufu
4. Kunywa Antenna 5. Ikimenyetso cyerekana 6. Icyambu cya Antenna
7. Icyambu cyo hasi 8. Icyambu cyitumanaho hagati ya host na PT voltage emitter 9. PT voltage yinjira
Umucumbitsi | 1pc |
Urubanza | 1pc |
Imashanyarazi ya PT | 1pc |
Umugozi wo kugerageza | 3pc |
Umugozi wo kugerageza amashanyarazi | 1pc |
Umugozi wubutaka | 2pc |
Itumanahoumugozi | 1pc |
Antenna | 2pc |
Amashanyarazi | 2pc |
Gucapa impapuro | 2rolls |
Umukoresha'smburi mwaka | 1pc |
Raporo y'ibizamini | 1pc |