GDB-P Imashini ihindura ibizamini
Ukurikije IEC hamwe n’ibipimo ngenderwaho bijyanye n’igihugu, ikigereranyo cyo guhindura ibipimo ni umushinga ukenewe mugikorwa cyo kubyara amashanyarazi, guhererekanya abakoresha no kugerageza kubungabunga.Ubu buryo burashobora gukurikirana neza ubwiza bwibicuruzwa byahinduwe muruganda no gukoresha inzira, birinda guhinduranya impinduka kugirango uhindure imirongo migufi, uruziga rufunguye, ikosa ryihuza, ikosa ryimbere cyangwa ikosa ryitumanaho rya kanda.
GDB-P Guhindura ibipimo bigereranya ibipimo biranga imikorere yoroshye, imikorere yuzuye, amakuru ahamye kandi yizewe.Kugeza ubu, GDB-P niyo yambere mubushinwa ishobora gukora ibipimo buhumyi (gushoboza gupima neza no gupima icyiciro cya fonction utazi uburyo bwo guhuza nuburyo itsinda ryifashe rya transformateur yapimwe);Irashobora guhaza ibikenerwa bitandukanye bigeragezwa bigereranywa (harimo guhinduranya ubwoko bwa Z, guhinduranya ibyuma, guhinduranya itanura ryamashanyarazi, guhinduranya icyiciro cya fonctionnement, guhindura traction, Scott na revers ya Scott).
GDB-P ifata ecran nini yuzuye-ibara LCD kugirango yerekane, icyerekezo cyuzuye cyicyongereza gishushanyo mbonera hamwe namakuru yerekana, ibice byinshi byerekana ibice, ibishushanyo mbonera byerekana amashusho hamwe nurubanza rwa wiring bitanga ishingiro ryizewe ryo kugenzura ukuri kwizunguruka.Gukoraho kwuzuye gukora silicone ya clavier imikorere, inzira nziza, byoroshye kwiga.Yubatswe mububiko bunini bwububiko bwamakuru, Irashobora kubika amakuru yo kugerageza kurubuga kugeza kumaseti 1000.Irashobora gutanga porogaramu yo gucunga microcomputer inyuma, kohereza ibisubizo kuri mudasobwa ukoresheje U disiki, gutanga raporo, gucapa, no kumenya imiyoborere ya mudasobwa.
Igikoresho gikoresha ubwubatsi bwa plastiki yububiko, bwiza kandi bufatika.
●Ikizamini cyukuri cyicyiciro cya gatatu: icyiciro kimwe cyinjiza ingufu, imbere ya digitale imbere yimibare itatu yicyiciro cya sine yerekana ibimenyetso, itanga ibyiciro bitatu byo gutanga amashanyarazi (kugoreka biri munsi ya 0.1%, guhuza ni byiza kurenza 0,05%) bisohoka binyuze imbaraga zo kwizerwa kwinshi, ibisubizo byikizamini bifite uburinganire bwiza, kandi ntihazabaho kwibeshya kwitsinda.
●Imbaraga: zishobora gukora igipimo kimwe cyo gupima, ariko kandi ikizamini cyikora cyicyiciro cya gatatu gishobora kugerwaho.Gupima polarite, inguni yicyiciro kimwe nicyiciro cya gatatu, gupima byuzuye bya AB, BC, CA igipimo cyicyiciro cya gatatu nigiciro cyicyiciro cyagaciro, ikosa, hamwe nikibanza gikanda, kanda agaciro icyarimwe, birashobora guhita byerekana umubare witsinda.
●Igipimo cyo gupima icyiciro: gupima neza inguni yicyiciro hagati yumuvuduko mwinshi kandi muto, uruhande nu mpande zimpinduka zitari integer zirashobora gupimwa.
●Imfuruka esheshatu zerekana ishusho: ibisubizo byikizamini byerekanwe numubare hamwe nigishushanyo cya gatandatu cyerekana icyerekezo, kandi ihinduka ryitsinda ryitsinda riraboneka neza.
●Imikorere yikizamini gihumye: ntagikeneye guhitamo uburyo bwo guhuza hamwe nitsinda ryihuza, ntagikenewe kumuzunguruko mugufi mugihe upima Y / △, transform / Y transformateur, uburyo bwo guhuza burashobora guhita buhinduka ukurikije ibizamini byatoranijwe.Ikigereranyo numubare wamatsinda birashobora gukorwa kuri transformateur idafite izina.
●Ikizamini cyo gukanda: gupima byihuse igereranyo nikosa ryikigereranyo mumwanya wa buri gihinduranya kanda, igipimo cyagenwe gikeneye kwinjiza rimwe gusa, nta mpamvu yo gusubiramo ibyinjijwe kugirango ubare ikosa ryikigereranyo cya buri mwanya.
●Guhindura igipimo no gukora voltage igipimo cyo gupima imikorere, igipimo cyo gukora kirashobora kwerekana mubyukuri igipimo cya voltage igereranya agaciro ka transformateur mugihe ibintu bigenda.
●Kurwanya kunyeganyega neza: gukoresha imiyoboro ya gisirikare byongereye imbaraga zo kurwanya vibrasiya.
●Yemeza 5.6 santimetero ndende-isobanura amabara ya ecran, kwerekana amakuru yerekana n'ingaruka za vector igishushanyo ni intiti kandi yoroshye.
●Digitally synthesised standard sine digital source, kugoreka ntabwo biri munsi ya 0.1%, ntibiterwa nubwiza bwimbaraga zakazi.
●Byoroshye gutwara: ingano nto, uburemere bworoshye.
●Bateri yimbere yumuriro, ikizamini kirashobora kurangira nta mashanyarazi ahari.
●Ikigereranyo cyo gupima: 0.8 ~ 10000
●Gupima umuvuduko: kurangiza ikizamini cyicyiciro cya gatatu muminota 1
●Gupima ubunyangamugayo: voltage yukuri kuruhande rwa HV: 0.05%
voltage yukuri kuruhande rwa LV: 0.1%
Icyerekezo cy'icyiciro: 0.1 °
ibipimo nyabyo: 0.1% (0.8-3000)
0.2% (3000-10000)
●Uburemere: 3kg.
●Amashanyarazi: 220V ± 10%, 50Hz ± 1Hz
●Ubushyuhe: -20 ℃ ~ 40 ℃
●Ubushuhe bugereranije: ≤ 85%, kudahuza