GDRB-B Guhindura Ibisubizo Bisesengura
Imbaraga za transformateur zihinduranya (uburyo bwo gusubiza inshuro) zishingiye ku gupima ibipimo biranga imiterere yimbere yimbere, ikoresha uburyo bwo gusesengura amakosa yimbere (FRA), irashobora kumenya neza amakosa yimbere ya transformateur.
Nyuma yo kurangiza gushushanya no gukora za transformateur, coil hamwe nimiterere yimbere birarangiye, kubwibyo rero coil ya transformateur ihinduranya byinshi, niba urwego rwa voltage nuburyo bwo guhinduranya ari bumwe, ibipimo bihuye (Ci, Li) bya buri igiceri kizagenwa.Kubwibyo, inshuro ziranga igisubizo kuri buri giceri nacyo kizagenwa, bityo imirongo yumurongo wa coil ihuye nibice bitatu iragereranywa.
Mugihe cyikizamini cya transformateur, mugihe habaye guhinduranya, guhuza intera ngufi, cyangwa kwimura coil ugereranije no kugongana mugihe cyo gutwara, kimwe no guhindura ibishishwa byaturutse kumyuka ya electromagnetiki mugihe ikora mugihe gito cyumuzunguruko nikibazo, ibipimo byo kugabura ya transformateur ihindagurika izahinduka, ibyo rero bigira ingaruka kandi bigahindura impinduka zumwimerere za domaine ziranga imiterere, aribyo guhinduranya inshuro mubunini hamwe na reonant yumurongo uhinduka.Igeragezwa rya transformateur yahinduwe ikurikije uburyo bwo gusesengura ibisubizo nigitabo gishya cya NDT ibikoresho byo kumenya amakosa yimbere.Irakoreshwa mugushakisha amakosa yimbere muri 63kV-500kV ihinduranya ingufu.
Igeragezwa rya Transformer ihinduranya ni ukumenya urugero rwimpinduka zimbere yimbere ya transformateur ukurikije ubwinshi bwimpinduka, ubunini nakarere bigira ingaruka kumihindagurikire hamwe nimpinduka zimpinduka zisubirwamo zigereranywa nimpinduka zasubiwemo muburyo butandukanye bwo guhinduranya imbere. ibipimo, hanyuma birashobora gufasha kumenya niba transformateur yangiritse cyane, cyangwa ikeneye kuvugururwa gukurikije ibisubizo byo gupima.
Kuri transformateur ikora, ntakibazo niba inshuro ya domaine iranga igishushanyo cyarakijijwe, mugereranije itandukaniro riri hagati ya coil iranga spekrice ya transformateur ikosa, irashobora kumenya urugero rwo gutsindwa.Byumvikane ko, niba warazigamye umwimerere wa transformateur yerekana ibintu bishushanya, bizoroha gutanga ishingiro ryukuri ryimikorere, gusesengura nyuma yamakosa no kuvugurura imikorere ya transformateur.
Igeragezwa rya Transformer winding deformation igizwe na mudasobwa igendanwa na mudasobwa igendanwa ikora sisitemu yo gupima neza hamwe nuburyo bworoshye, imikorere yoroshye, hamwe nibikorwa byinshi byo gusesengura ibizamini, bishobora gukoreshwa hifashishijwe igitabo cyigisha cyangwa binyuze mumahugurwa y'igihe gito.
●Kubona no kugenzura ukoresheje umuvuduko mwinshi, microprocessor ihuriweho cyane.
●Itumanaho USB interineti ikoreshwa hagati ya mudasobwa igendanwa.
●Wireless WIFI Imigaragarire cyangwa Bluetooth (itabishaka) ikoreshwa hagati ya mudasobwa igendanwa nigikoresho.
●Ibyuma byifashisha tekinoroji ya DDS yihariye yihuta yo gusikana (USA), irashobora gusuzuma neza amakosa nkumuyaga ugoretse, uhindagurika, uhinduranya, uhindagurika, uhinduranya imirongo migufi-ihindagurika no guhuza ibice bigufi.
●Umuvuduko mwinshi-umuyoboro-16-bit A / D icyitegererezo (mukigeragezo cyumurima, kwimura igikanda, hamwe numurongo wikurikiranya werekana impinduka zigaragara).
●Ibimenyetso byerekana amplitude byahinduwe na software, kandi agaciro ka amplitude ni ± 10V.
●Mudasobwa izahita isesengura ibisubizo byikizamini kandi itange inyandiko za elegitoronike (Ijambo).
●Igikoresho gifite ibipimo bibiri byo gupima: gupima umurongo wumurongo wo gupima no gupima igice cyogusuzuma, guhuza nuburyo bwo gupima amatsinda abiri ya tekinike mubushinwa
●Ibiranga amplitude-frequency birahuye nibisobanuro bya tekiniki yigihugu kubijyanye na test ya amplitude-frequency ibiranga.X.Umukoresha arashobora guhitamo ukurikije ibikenewe.
●Sisitemu yo gusesengura amakuru yikora,
Kugereranya gutambitse kugereranya guhuza ibice bitatu A, B na C.
Ibisubizo ni ibi bikurikira:
●Guhoraho bihebuje
●Guhora neza
●Guhuzagurika nabi
●Guhora mubi
Kugereranya birebire AA, BB, CC yita amakuru yumwimerere hamwe namakuru agezweho mugice kimwe cyo kugereranya ihindagurika
Ibisubizo by'isesengura ni:
●Guhinduranya bisanzwe
●Guhindura byoroheje
●Guhindura ibintu mu rugero
●Guhinduka gukabije
Ijambo inyandiko ya elegitoronike irashobora guhita ikorwa kugirango ubike no gucapa.
Igikoresho kirashobora kuzuza byuzuye ibisabwa bya tekiniki yumuriro w'amashanyarazi DL / T911-2004 "Isesengura ryibisubizo byerekeranye no guhindura imikorere ya transformateur".
Uburyo bwa Scan:
1. Gukwirakwiza umurongo wo gusikana
Ikigereranyo cyo gupima: (10Hz) - (10MHz) 40000 yo gusikana, gukemura 0.25kHz, 0.5kHz na 1kHz.
2. Segment frequency scanning ibipimo byo gupima
Ibipimo byo gupima inshuro: (0.5kHz) - (1MHz), amanota 2000 yo gusikana;(0.5kHz) - (10kHz);(10kHz) - (100kHz);(100kHz) - (500kHz);(500kHz) - (1000kHz)
Ibindi bikoresho bya tekiniki:
1. Ikigereranyo cyo gupima Amplitude: (-120dB) kugeza (+20 dB);
2. Ibipimo bya Amplitude byukuri: 1dB;
3. Gusikana inshuro zuzuye: 0.005% / 0.01%;
4. Ibimenyetso byinjira byinjira: 1MΩ;
5. Ibimenyetso byo gusohora inzitizi: 50Ω;
6. Ibimenyetso byerekana amplitude: ± 20V;
7. Mu cyiciro cyo gusubiramo ikizamini cyo gusubiramo: 99.9%;
8. Ibipimo bipima ibipimo (LxWxH): 350 * 300 * 140 (mm) / 300 * 340 * 120 (mm);
9. Igikoresho cya aluminiyumu yububiko (LxWxH): 390 * 310 * 340 (mm) / 310 * 400 * 330 (mm);
10. Uburemere muri rusange: 13kg / 10kg;
11. ubushyuhe bwakazi: -10 ℃ ~ + 40 ℃;
Ubushyuhe bwo kubika: -20 ℃ ~ + 70 ℃;
Ubushuhe bugereranije: <90%, Kudashyira hamwe;
Igice nyamukuru | 1 |
Ikizamini cyo gusubiza inshuro ziyobora 50W / (>15m) | 2 |
Ikizamini cyo gupima, umuhondo, icyatsi (200A) | 2 |
Umugozi wubutaka (umukara, insinga z'umuringa 5M) | 4 |
Gufata hasi (umukara) | 2 |
Umugozi w'itumanaho rya USB | 1 |
Kwinjiza software CD-ROM Imiterere ya VCD | 1 |
Kwinjizamo software USB disiki 16G | 1 |
Fuse 0.5A | 3 |
Umugozi w'amashanyarazi & adapt | 1 |
Imfashanyigisho y'abakoresha | 1 |
Ikarita ya garanti | 1 |
Urutonde | 1 |
Raporo y'ibizamini by'uruganda | 1 |